Cardiac lipid levels show diurnal changes and long‐term variations in healthy human subjects. (2nd September 2014)
- Record Type:
- Journal Article
- Title:
- Cardiac lipid levels show diurnal changes and long‐term variations in healthy human subjects. (2nd September 2014)
- Main Title:
- Cardiac lipid levels show diurnal changes and long‐term variations in healthy human subjects
- Authors:
- Ith, Michael
Stettler, Christoph
Xu, Jian
Boesch, Chris
Kreis, Roland - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p> <sup>1</sup>H‐MRS is regularly applied to determine lipid content in ectopic tissue – mostly skeletal muscle and liver – to investigate physiological and/or pathologic conditions, e.g. insulin resistance. Technical developments also allow non‐invasive <italic>in vivo</italic> assessment of cardiac lipids; however, basic data about methodological reliability (repeatability) and physiological variations are scarce. The aim of the presented work was to determine potential diurnal changes of cardiac lipid stores in humans, and to put the results in relation to methodological repeatability and normal physiological day‐to‐day variations.</p> <p>Optimized cardiac‐ and respiratory‐gated <sup>1</sup>H‐MRS was used for non‐invasive quantification of intracardiomyocellular lipids (ICCL), creatine, trimethyl‐ammonium compounds (TMA), and taurine in nine healthy young men at three time points per day on two days separated by one week. This design allowed determination of (a) diurnal changes, (b) physiological variation over one week and (c) methodological repeatability of the ICCL levels.</p> <p>Comparison of fasted morning to post‐absorptive evening measurements revealed a significant 37 ± 19% decrease of ICCL during the day (<italic>p</italic> = 0.0001). There was a significant linear correlation between ICCL levels in the morning and their decrease during the day (<italic>p</italic> = 0.015).<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p> <sup>1</sup>H‐MRS is regularly applied to determine lipid content in ectopic tissue – mostly skeletal muscle and liver – to investigate physiological and/or pathologic conditions, e.g. insulin resistance. Technical developments also allow non‐invasive <italic>in vivo</italic> assessment of cardiac lipids; however, basic data about methodological reliability (repeatability) and physiological variations are scarce. The aim of the presented work was to determine potential diurnal changes of cardiac lipid stores in humans, and to put the results in relation to methodological repeatability and normal physiological day‐to‐day variations.</p> <p>Optimized cardiac‐ and respiratory‐gated <sup>1</sup>H‐MRS was used for non‐invasive quantification of intracardiomyocellular lipids (ICCL), creatine, trimethyl‐ammonium compounds (TMA), and taurine in nine healthy young men at three time points per day on two days separated by one week. This design allowed determination of (a) diurnal changes, (b) physiological variation over one week and (c) methodological repeatability of the ICCL levels.</p> <p>Comparison of fasted morning to post‐absorptive evening measurements revealed a significant 37 ± 19% decrease of ICCL during the day (<italic>p</italic> = 0.0001). There was a significant linear correlation between ICCL levels in the morning and their decrease during the day (<italic>p</italic> = 0.015). Methodological repeatability for the ICCL/creatine ratio was excellent, with a coefficient of variance of ~5%, whereas physiological variation was found to be considerably higher (22%) in spite of a standardized physiological preparation protocol. In contrast, TMA levels remained stable over this time period.</p> <p>The proposed <sup>1</sup>H‐MRS technique provides a robust way to investigate relevant physiological changes in cardiac metabolites, in particular ICCL. The present results suggest that ICCL reveal a diurnal course, with higher levels in the morning as compared to evening. In addition, a considerable long‐term variation of ICCL levels, in both the morning and evening, was documented. Given the high methodological repeatability, these effects should be taken into account in studies investigating the metabolic role of ICCL. Copyright © 2014 John Wiley &amp; Sons, Ltd.</p> </abstract> … (more)
- Is Part Of:
- NMR in biomedicine. Volume 27:Number 11(2014:Nov.)
- Journal:
- NMR in biomedicine
- Issue:
- Volume 27:Number 11(2014:Nov.)
- Issue Display:
- Volume 27, Issue 11 (2014)
- Year:
- 2014
- Volume:
- 27
- Issue:
- 11
- Issue Sort Value:
- 2014-0027-0011-0000
- Page Start:
- 1285
- Page End:
- 1292
- Publication Date:
- 2014-09-02
- Subjects:
- Nuclear magnetic resonance -- Periodicals
Magnetic Resonance Spectroscopy -- Periodicals
574 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/nbm.3186 ↗
- Languages:
- English
- ISSNs:
- 0952-3480
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6113.931000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4010.xml