Ionic liquid foam floatation coupled with ionic liquid dispersive liquid–liquid microextraction for the separation and determination of estrogens in water samples by high‐performance liquid chromatography with fluorescence detection. Issue 21 (23rd September 2014)
- Record Type:
- Journal Article
- Title:
- Ionic liquid foam floatation coupled with ionic liquid dispersive liquid–liquid microextraction for the separation and determination of estrogens in water samples by high‐performance liquid chromatography with fluorescence detection. Issue 21 (23rd September 2014)
- Main Title:
- Ionic liquid foam floatation coupled with ionic liquid dispersive liquid–liquid microextraction for the separation and determination of estrogens in water samples by high‐performance liquid chromatography with fluorescence detection
- Authors:
- Zhang, Rui
Wang, Chuanliu
Yue, Qiaohong
Zhou, Tiecheng
Li, Na
Zhang, Hanqi
Hao, Xiaoke - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>An ionic liquid foam floatation coupled with ionic liquid dispersive liquid–liquid microextraction method was proposed for the extraction and concentration of 17‐α‐estradiol, 17‐β‐estradiol‐benzoate, and quinestrol in environmental water samples by high‐performance liquid chromatography with fluorescence detection. 1‐Hexyl‐3‐methylimidazolium tetrafluoroborate was applied as foaming agent in the foam flotation process and dispersive solvent in microextraction. The introduction of the ion‐pairing and salting‐out agent NH<sub>4</sub>PF<sub>6</sub> was beneficial to the improvement of recoveries for the hydrophobic ionic liquid phase and analytes. Parameters of the proposed method including concentration of 1‐hexyl‐3‐methylimidazolium tetrafluoroborate, flow rate of carrier gas, floatation time, types and concentration of ionic liquids, salt concentration in samples, extraction time, and centrifugation time were evaluated. The recoveries were between 98 and 105% with relative standard deviations lower than 7% for lake water and well water samples. The isolation of the target compounds from the water was found to be efficient, and the enrichment factors ranged from 4445 to 4632. This developing method is free of volatile organic solvents compared with regular extraction. Based on the unique properties of ionic liquids, the application of foam floatation, and dispersive liquid–liquid<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>An ionic liquid foam floatation coupled with ionic liquid dispersive liquid–liquid microextraction method was proposed for the extraction and concentration of 17‐α‐estradiol, 17‐β‐estradiol‐benzoate, and quinestrol in environmental water samples by high‐performance liquid chromatography with fluorescence detection. 1‐Hexyl‐3‐methylimidazolium tetrafluoroborate was applied as foaming agent in the foam flotation process and dispersive solvent in microextraction. The introduction of the ion‐pairing and salting‐out agent NH<sub>4</sub>PF<sub>6</sub> was beneficial to the improvement of recoveries for the hydrophobic ionic liquid phase and analytes. Parameters of the proposed method including concentration of 1‐hexyl‐3‐methylimidazolium tetrafluoroborate, flow rate of carrier gas, floatation time, types and concentration of ionic liquids, salt concentration in samples, extraction time, and centrifugation time were evaluated. The recoveries were between 98 and 105% with relative standard deviations lower than 7% for lake water and well water samples. The isolation of the target compounds from the water was found to be efficient, and the enrichment factors ranged from 4445 to 4632. This developing method is free of volatile organic solvents compared with regular extraction. Based on the unique properties of ionic liquids, the application of foam floatation, and dispersive liquid–liquid microextraction was widened.</p> </abstract> … (more)
- Is Part Of:
- Journal of separation science. Volume 37:Issue 21(2014:Nov.)
- Journal:
- Journal of separation science
- Issue:
- Volume 37:Issue 21(2014:Nov.)
- Issue Display:
- Volume 37, Issue 21 (2014)
- Year:
- 2014
- Volume:
- 37
- Issue:
- 21
- Issue Sort Value:
- 2014-0037-0021-0000
- Page Start:
- 3133
- Page End:
- 3141
- Publication Date:
- 2014-09-23
- Subjects:
- Separation (Technology) -- Periodicals
Chromatographic analysis -- Periodicals
543.089 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1615-9314 ↗
http://www.interscience.wiley.com/jpages/1615-9306 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jssc.201400568 ↗
- Languages:
- English
- ISSNs:
- 1615-9306
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5063.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4310.xml