Application of an optimized dispersive nanomaterial ultrasound‐assisted microextraction method for preconcentration of carbofuran and propoxur and their determination by high‐performance liquid chromatography with UV detection. Issue 21 (18th September 2014)
- Record Type:
- Journal Article
- Title:
- Application of an optimized dispersive nanomaterial ultrasound‐assisted microextraction method for preconcentration of carbofuran and propoxur and their determination by high‐performance liquid chromatography with UV detection. Issue 21 (18th September 2014)
- Main Title:
- Application of an optimized dispersive nanomaterial ultrasound‐assisted microextraction method for preconcentration of carbofuran and propoxur and their determination by high‐performance liquid chromatography with UV detection
- Authors:
- Khodadoust, Saeid
Talebianpoor, Mohammad Sharif
Ghaedi, Mehrorang - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>An extraction method based on dispersive nanomaterial ultrasound‐assisted microextraction was used for the preconcentration of carbofuran and propoxur insecticides in water samples prior to high‐performance liquid chromatography with UV detection. ZnS:Ni nanoparticles were synthesized based on the reaction of the mixture of zinc acetate and nickel acetate with thioacetamide in aqueous media and then loaded on activated carbon (ZnS:Ni‐AC). Different methods were used for recognizing the properties of ZnS:Ni‐AC and then this nanomaterial was used for extraction of carbamate insecticide as new adsorbent. The influence of variables on the extraction method (such as amount of adsorbent (mg: NiZnS‐AC), pH and ionic strength of sample solution, vortex and ultrasonic time (min), ultrasound temperature and desorption volume (mL) was investigated by a screening 2<sup>7–4</sup> Plackett–Burman design. Then the significant variables were optimized by using a central composite design combined with a desirability function. At optimum conditions, this method had linear response >0.0060–10 μg/mL with detection limit 0.0015 μg/mL and relative standard deviations <5.0% (<italic>n</italic> = 3).</p> </abstract>
- Is Part Of:
- Journal of separation science. Volume 37:Issue 21(2014:Nov.)
- Journal:
- Journal of separation science
- Issue:
- Volume 37:Issue 21(2014:Nov.)
- Issue Display:
- Volume 37, Issue 21 (2014)
- Year:
- 2014
- Volume:
- 37
- Issue:
- 21
- Issue Sort Value:
- 2014-0037-0021-0000
- Page Start:
- 3117
- Page End:
- 3124
- Publication Date:
- 2014-09-18
- Subjects:
- Separation (Technology) -- Periodicals
Chromatographic analysis -- Periodicals
543.089 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1615-9314 ↗
http://www.interscience.wiley.com/jpages/1615-9306 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jssc.201400816 ↗
- Languages:
- English
- ISSNs:
- 1615-9306
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5063.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4310.xml