Inter-examiner variability and agreement of the alternate prism cover test (APCT) measurements of strabismus performed by 4 examiners*. (December 2014)
- Record Type:
- Journal Article
- Title:
- Inter-examiner variability and agreement of the alternate prism cover test (APCT) measurements of strabismus performed by 4 examiners*. (December 2014)
- Main Title:
- Inter-examiner variability and agreement of the alternate prism cover test (APCT) measurements of strabismus performed by 4 examiners*
- Authors:
- de Jongh, E.
Leach, C.
Tjon-Fo-Sang, M.J.
Bjerre, A. - Abstract:
- <abstract> <title>Abstract</title> <p> <italic>Purpose</italic>: To investigate the inter-examiner variability and agreement of the alternate prism cover test (APCT) measurements of strabismus at near and distance fixation performed by 4 examiners. <italic>Methods</italic>: Forty-one participants (median age 12 years, range 3–74) with horizontal strabismus completed APCT measurements at near (1/3 m) and distance (5 m) fixation. Each participant was assessed by 4 masked experienced orthoptists on the same visit. Bland-Altman plots and inter-examiner variability (1.96xSD of the difference) were used to determine a clinical value suggestive of real change. <italic>Results</italic>: The inter-examiner variability was ±10 prism diopters (PD) at near and ±9 PD at distance fixation. The mean difference between measurements per examiner pair for near fixation ranged between −3 and 1.5 PD, with inter-examiner variability ranging between ±6.9 and ±12.5 PD, and mean difference for distance fixation between −0.8 and 1.6 PD, with inter-examiner variability ranging between ±7.5 and ±11.7 PD. Larger variability was found between some examiner pairs than others. Magnitude of the deviation, test distance, and age had no significant influence on the variation in APCT measurement. <italic>Conclusion</italic>: A variation in APCT measurement between 4 examiners of less than 10 PD for both near and distance fixation is likely to be due to inter-examiner variability. Changes of 10 PD or more are<abstract> <title>Abstract</title> <p> <italic>Purpose</italic>: To investigate the inter-examiner variability and agreement of the alternate prism cover test (APCT) measurements of strabismus at near and distance fixation performed by 4 examiners. <italic>Methods</italic>: Forty-one participants (median age 12 years, range 3–74) with horizontal strabismus completed APCT measurements at near (1/3 m) and distance (5 m) fixation. Each participant was assessed by 4 masked experienced orthoptists on the same visit. Bland-Altman plots and inter-examiner variability (1.96xSD of the difference) were used to determine a clinical value suggestive of real change. <italic>Results</italic>: The inter-examiner variability was ±10 prism diopters (PD) at near and ±9 PD at distance fixation. The mean difference between measurements per examiner pair for near fixation ranged between −3 and 1.5 PD, with inter-examiner variability ranging between ±6.9 and ±12.5 PD, and mean difference for distance fixation between −0.8 and 1.6 PD, with inter-examiner variability ranging between ±7.5 and ±11.7 PD. Larger variability was found between some examiner pairs than others. Magnitude of the deviation, test distance, and age had no significant influence on the variation in APCT measurement. <italic>Conclusion</italic>: A variation in APCT measurement between 4 examiners of less than 10 PD for both near and distance fixation is likely to be due to inter-examiner variability. Changes of 10 PD or more are suggestive of a real change and may be employed as a management threshold.</p> </abstract> … (more)
- Is Part Of:
- Strabismus. Volume 22:Number 4(2014:Dec.)
- Journal:
- Strabismus
- Issue:
- Volume 22:Number 4(2014:Dec.)
- Issue Display:
- Volume 22, Issue 4 (2014)
- Year:
- 2014
- Volume:
- 22
- Issue:
- 4
- Issue Sort Value:
- 2014-0022-0004-0000
- Page Start:
- 158
- Page End:
- 166
- Publication Date:
- 2014-12
- Subjects:
- Strabismus -- Periodicals
Neurophysiology -- Periodicals
617.762 - Journal URLs:
- http://informahealthcare.com/loi/str ↗
http://informahealthcare.com ↗
http://www.tandf.co.uk/journals/titles/09273972.asp ↗ - DOI:
- 10.3109/09273972.2014.972521 ↗
- Languages:
- English
- ISSNs:
- 0927-3972
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8467.548000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3163.xml