Precision and Accuracy of TearLab Osmometer in Measuring Osmolarity of Salt Solutions. (December 2014)
- Record Type:
- Journal Article
- Title:
- Precision and Accuracy of TearLab Osmometer in Measuring Osmolarity of Salt Solutions. (December 2014)
- Main Title:
- Precision and Accuracy of TearLab Osmometer in Measuring Osmolarity of Salt Solutions
- Authors:
- Yoon, Dan
Gadaria-Rathod, Neha
Oh, Cheongeun
Asbell, Penny A. - Abstract:
- <abstract> <title>Abstract</title> <p> <italic>Purpose</italic>: The purpose of this study was to examine the inherent precision and accuracy of TearLab Osmolarity System using salt solutions, including solutions of very high osmolarity (&gt;360 mOsm/L).</p> <p> <italic>Materials and methods</italic>: Ten salt solutions with osmolarity between 286 mOsm/L and 394 mOsm/L (increments of 12 mOsm/L) plus an additional solution of 400 mOsm/L were tested twice on both the TearLab osmometer and a freezing point depression osmometer. For precision, we compared the two repeated osmolarity measurements of 11 solutions obtained from TearLab. For accuracy, we compared the averaged osmolarity measurements obtained from TearLab to those from the freezing point depression osmometer. For both precision and accuracy, Bland–Altman test of agreement was used.</p> <p> <italic>Results</italic>: For precision, the upper 95% limit of agreement was 4.7 mOsm/L, and the lower 95% limit of agreement was −7.1 mOsm/L. The repeatability coefficient was 5.9 mOsm/L. For accuracy, the upper 95% limit of agreement was 4.8 mOsm/L and the lower 95% limit of agreement was −5.3 mOsm/L.</p> <p> <italic>Conclusions</italic>: The present study is the first study to demonstrate that the TearLab <italic>in situ</italic> osmometer can precisely and accurately measure osmolarity of salt solutions, including those with very high osmolarity. Future studies to evaluate the precision and the accuracy of the machine in<abstract> <title>Abstract</title> <p> <italic>Purpose</italic>: The purpose of this study was to examine the inherent precision and accuracy of TearLab Osmolarity System using salt solutions, including solutions of very high osmolarity (&gt;360 mOsm/L).</p> <p> <italic>Materials and methods</italic>: Ten salt solutions with osmolarity between 286 mOsm/L and 394 mOsm/L (increments of 12 mOsm/L) plus an additional solution of 400 mOsm/L were tested twice on both the TearLab osmometer and a freezing point depression osmometer. For precision, we compared the two repeated osmolarity measurements of 11 solutions obtained from TearLab. For accuracy, we compared the averaged osmolarity measurements obtained from TearLab to those from the freezing point depression osmometer. For both precision and accuracy, Bland–Altman test of agreement was used.</p> <p> <italic>Results</italic>: For precision, the upper 95% limit of agreement was 4.7 mOsm/L, and the lower 95% limit of agreement was −7.1 mOsm/L. The repeatability coefficient was 5.9 mOsm/L. For accuracy, the upper 95% limit of agreement was 4.8 mOsm/L and the lower 95% limit of agreement was −5.3 mOsm/L.</p> <p> <italic>Conclusions</italic>: The present study is the first study to demonstrate that the TearLab <italic>in situ</italic> osmometer can precisely and accurately measure osmolarity of salt solutions, including those with very high osmolarity. Future studies to evaluate the precision and the accuracy of the machine in measuring complex fluids, such as tears, need to be done, and the clinical significance of measuring tear osmolarity in patients needs to be further determined.</p> </abstract> … (more)
- Is Part Of:
- Current eye research. Volume 39:Number 12(2014:Dec.)
- Journal:
- Current eye research
- Issue:
- Volume 39:Number 12(2014:Dec.)
- Issue Display:
- Volume 39, Issue 12 (2014)
- Year:
- 2014
- Volume:
- 39
- Issue:
- 12
- Issue Sort Value:
- 2014-0039-0012-0000
- Page Start:
- 1247
- Page End:
- 1250
- Publication Date:
- 2014-12
- Subjects:
- Ophthalmology -- Periodicals
Eye -- Diseases -- Periodicals
Ophthalmology -- Periodicals
573.88 - Journal URLs:
- http://informahealthcare.com/journal/cey ↗
http://www.tandfonline.com/toc/icey20/current ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/02713683.2014.906623 ↗
- Languages:
- English
- ISSNs:
- 0271-3683
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3496.570000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3218.xml