Development and performance evaluation of a positive reference material for hemolysis testing. Issue 8 (8th April 2014)
- Record Type:
- Journal Article
- Title:
- Development and performance evaluation of a positive reference material for hemolysis testing. Issue 8 (8th April 2014)
- Main Title:
- Development and performance evaluation of a positive reference material for hemolysis testing
- Authors:
- Haishima, Yuji
Hasegawa, Chie
Nomura, Yusuke
Kawakami, Tsuyoshi
Yuba, Toshiyasu
Shindo, Tomoko
Sakaguchi, Keisuke
Tanigawa, Takahiro
Inukai, Kaori
Takenouchi, Mika
Isama, Kazuo
Matsuoka, Atsuko
Niimi, Shingo - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <p>This study deals with the development and performance evaluation of a positive reference material for hemolysis testing, which is used for evaluating the biological safety of medical devices. Genapol X‐080, a nonionic detergent, was selected as a candidate hemolytic substance in a survey of 23 chemical compounds; it showed significant hemolytic activity against rabbit defibrinated blood at concentrations more than 20 µg/mL. A polyvinyl chloride (PVC) sheet spiked with 0.6% (w/w) of the compound exhibited weak hemolytic activity in direct contact and/or extract‐based assays after 4 h incubation at 37°C. A PVC sheet containing 5.8% (w/w) Genapol X‐080 induced complete hemolysis in both assays. The amount of Genapol X‐080 eluted from each PVC sheet during hemolysis testing using the direct contact method increased time‐dependently and reached 25.6 (former sheet) or 1154 (later sheet) µg/mL after 4 h incubation, which was similar to or much higher than the critical micelle concentration, respectively. Similar elution behavior was observed using the extract‐based method, and the Genapol X‐080 content in test solutions prepared by autoclave extraction of both sheets was 22.5 and 358 µg/mL, respectively, indicating a clear relationship between the degree of hemolytic activity and the eluted amount of Genapol X‐080. Thus, a PVC sheet spiked with a compound exhibiting different hemolytic activity depending on its<abstract abstract-type="main"> <title>Abstract</title> <p>This study deals with the development and performance evaluation of a positive reference material for hemolysis testing, which is used for evaluating the biological safety of medical devices. Genapol X‐080, a nonionic detergent, was selected as a candidate hemolytic substance in a survey of 23 chemical compounds; it showed significant hemolytic activity against rabbit defibrinated blood at concentrations more than 20 µg/mL. A polyvinyl chloride (PVC) sheet spiked with 0.6% (w/w) of the compound exhibited weak hemolytic activity in direct contact and/or extract‐based assays after 4 h incubation at 37°C. A PVC sheet containing 5.8% (w/w) Genapol X‐080 induced complete hemolysis in both assays. The amount of Genapol X‐080 eluted from each PVC sheet during hemolysis testing using the direct contact method increased time‐dependently and reached 25.6 (former sheet) or 1154 (later sheet) µg/mL after 4 h incubation, which was similar to or much higher than the critical micelle concentration, respectively. Similar elution behavior was observed using the extract‐based method, and the Genapol X‐080 content in test solutions prepared by autoclave extraction of both sheets was 22.5 and 358 µg/mL, respectively, indicating a clear relationship between the degree of hemolytic activity and the eluted amount of Genapol X‐080. Thus, a PVC sheet spiked with a compound exhibiting different hemolytic activity depending on its concentration may be useful as a positive reference material to validate the hemolysis tests. © 2014 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 102B: 1809–1816, 2014.</p> </abstract> … (more)
- Is Part Of:
- Journal of biomedical materials research. Volume 102:Issue 8(2014:Nov.)
- Journal:
- Journal of biomedical materials research
- Issue:
- Volume 102:Issue 8(2014:Nov.)
- Issue Display:
- Volume 102, Issue 8 (2014)
- Year:
- 2014
- Volume:
- 102
- Issue:
- 8
- Issue Sort Value:
- 2014-0102-0008-0000
- Page Start:
- 1809
- Page End:
- 1816
- Publication Date:
- 2014-04-08
- Subjects:
- Biomedical materials -- Periodicals
610.28 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jbm.b.33169 ↗
- Languages:
- English
- ISSNs:
- 1552-4973
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.725000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3053.xml