Mechanical properties of a cemented porous implant interface. (September 2014)
- Record Type:
- Journal Article
- Title:
- Mechanical properties of a cemented porous implant interface. (September 2014)
- Main Title:
- Mechanical properties of a cemented porous implant interface
- Authors:
- Beckmann, Nicholas A
Bitsch, Rudi G
Seeger, Joern B
Klotz, Matthias CM
Kretzer, Jan Philippe
Jaeger, Sebastian - Abstract:
- <abstract> <title> <x xml:space="preserve">Abstract</x> </title> <p> <bold>Background —</bold> Revision arthroplasty often requires anchoring of prostheses to poor-quality or deficient bone stock. Recently, newer porous materials have been introduced onto the market as additional, and perhaps better, treatment options for revision arthroplasty. To date, there is no information on how these porous metals interface with bone cement. This is of clinical importance, since these components may require cementing to other prosthesis components and occasionally to bone.</p> <p> <bold>Methods —</bold> We created porous metal and bone cylinders of the same size and geometry and cemented them in a well-established standardized setting. These were then placed under tensile loading and torsional loading until failure was achieved. This permitted comparison of the porous metal/cement interface (group A) with the well-studied bone/cement interface (group B).</p> <p> <bold>Results —</bold> The group A interface was statistically significantly stronger than the group B interface, despite having significantly reduced depth of cement penetration: it showed a larger maximum tensile force (effect size 2.7), superior maximum tensile strength (effect size 2.6), greater maximum torsional force (effect size 2.2), and higher rotational stiffness (effect size 1.5).</p> <p> <bold>Interpretation —</bold> The newer porous implants showed good interface properties when cemented using medium-viscosity bone<abstract> <title> <x xml:space="preserve">Abstract</x> </title> <p> <bold>Background —</bold> Revision arthroplasty often requires anchoring of prostheses to poor-quality or deficient bone stock. Recently, newer porous materials have been introduced onto the market as additional, and perhaps better, treatment options for revision arthroplasty. To date, there is no information on how these porous metals interface with bone cement. This is of clinical importance, since these components may require cementing to other prosthesis components and occasionally to bone.</p> <p> <bold>Methods —</bold> We created porous metal and bone cylinders of the same size and geometry and cemented them in a well-established standardized setting. These were then placed under tensile loading and torsional loading until failure was achieved. This permitted comparison of the porous metal/cement interface (group A) with the well-studied bone/cement interface (group B).</p> <p> <bold>Results —</bold> The group A interface was statistically significantly stronger than the group B interface, despite having significantly reduced depth of cement penetration: it showed a larger maximum tensile force (effect size 2.7), superior maximum tensile strength (effect size 2.6), greater maximum torsional force (effect size 2.2), and higher rotational stiffness (effect size 1.5).</p> <p> <bold>Interpretation —</bold> The newer porous implants showed good interface properties when cemented using medium-viscosity bone cement. The axial and rotational mechanical strength of a porous metal/cement interface appeared to be greater than the strength of the standard bone/cement interface. These results indicate that cementing of porous implants can provide great stability in situations where it is needed.</p> </abstract> … (more)
- Is Part Of:
- Acta orthopaedica. Volume 85:Number 5(2014)
- Journal:
- Acta orthopaedica
- Issue:
- Volume 85:Number 5(2014)
- Issue Display:
- Volume 85, Issue 5 (2014)
- Year:
- 2014
- Volume:
- 85
- Issue:
- 5
- Issue Sort Value:
- 2014-0085-0005-0000
- Page Start:
- 531
- Page End:
- 537
- Publication Date:
- 2014-09
- Subjects:
- Orthopedics -- Periodicals
616.7005 - Journal URLs:
- http://informahealthcare.com/loi/ort ↗
http://www.tandfonline.com/toc/iort20/current ↗
https://actaorthop.org/actao/index ↗
http://www.tandfonline.com/ ↗
http://journalsonline.tandf.co.uk/app/home/journal.asp?wasp=65168817ff044fea9c5b577f1cfe2186&referrer=parent&backto=linkingpublicationresults, 1:113260, 1 ↗ - DOI:
- 10.3109/17453674.2014.919557 ↗
- Languages:
- English
- ISSNs:
- 1745-3674
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0642.055000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3082.xml