Correction of diffusion-weighted magnetic resonance imaging for brachytherapy of locally advanced cervical cancer. (August 2014)
- Record Type:
- Journal Article
- Title:
- Correction of diffusion-weighted magnetic resonance imaging for brachytherapy of locally advanced cervical cancer. (August 2014)
- Main Title:
- Correction of diffusion-weighted magnetic resonance imaging for brachytherapy of locally advanced cervical cancer
- Authors:
- Haack, Søren
Kallehauge, Jesper F.
Jespersen, Sune N.
Lindegaard, Jacob C.
Tanderup, Kari
Pedersen, Erik M. - Abstract:
- <abstract> <title>Abstract</title> <p> <bold>Background</bold>. Geometrical distortion is a major obstacle for the use of echo planar diffusion-weighted magnetic resonance imaging (DW-MRI) in planning of radiotherapy. This study compares geometrical distortion correction methods of DW-MRI at time of brachytherapy (BT) in locally advanced cervical cancer patients.</p> <p> <bold>Material and methods.</bold> In total 21 examinations comprising DW-MRI, dual gradient echo (GRE) for B<sub>0</sub> field map calculation and T2-weighted (T2W) fat-saturated MRI of eight patients with locally advanced cervical cancer were acquired during BT with a plastic tandem and ring applicator in situ. The ability of B<sub>0</sub> field map correction (B<sub>0</sub>M) and deformable image registration (DIR) to correct DW-MRI geometric image distortion was compared to the non-corrected DW-MRI including evaluation of apparent diffusion coefficient (ADC) for the gross tumor volume (GTV).</p> <p> <bold>Results.</bold> Geometrical distortion correction decreased tandem displacement from 3.3 ± 0.9 mm (non-corrected) to 2.9 ± 1.0 mm (B<sub>0</sub>M) and 1.9 ± 0.6 mm (DIR), increased mean normalized cross-correlation from 0.69 ± 0.1 (non- corrected) to 0.70 ± 0.10 (B<sub>0</sub>M) and 0.77 ± 0.1 (DIR), and increased the Jaccard similarity coefficient from 0.72 ± 0.1 (non-corrected) to 0.73 ± 0.06 (B<sub>0</sub>M) and 0.77 ± 0.1 (DIR). For all parameters only DIR corrections were significant (p &lt; 0.05).<abstract> <title>Abstract</title> <p> <bold>Background</bold>. Geometrical distortion is a major obstacle for the use of echo planar diffusion-weighted magnetic resonance imaging (DW-MRI) in planning of radiotherapy. This study compares geometrical distortion correction methods of DW-MRI at time of brachytherapy (BT) in locally advanced cervical cancer patients.</p> <p> <bold>Material and methods.</bold> In total 21 examinations comprising DW-MRI, dual gradient echo (GRE) for B<sub>0</sub> field map calculation and T2-weighted (T2W) fat-saturated MRI of eight patients with locally advanced cervical cancer were acquired during BT with a plastic tandem and ring applicator in situ. The ability of B<sub>0</sub> field map correction (B<sub>0</sub>M) and deformable image registration (DIR) to correct DW-MRI geometric image distortion was compared to the non-corrected DW-MRI including evaluation of apparent diffusion coefficient (ADC) for the gross tumor volume (GTV).</p> <p> <bold>Results.</bold> Geometrical distortion correction decreased tandem displacement from 3.3 ± 0.9 mm (non-corrected) to 2.9 ± 1.0 mm (B<sub>0</sub>M) and 1.9 ± 0.6 mm (DIR), increased mean normalized cross-correlation from 0.69 ± 0.1 (non- corrected) to 0.70 ± 0.10 (B<sub>0</sub>M) and 0.77 ± 0.1 (DIR), and increased the Jaccard similarity coefficient from 0.72 ± 0.1 (non-corrected) to 0.73 ± 0.06 (B<sub>0</sub>M) and 0.77 ± 0.1 (DIR). For all parameters only DIR corrections were significant (p &lt; 0.05). ADC of the GTV did not change significantly with either correction method.</p> <p> <bold>Conclusion.</bold> DIR significantly improved geometrical accuracy of DW-MRI, with remaining residual uncertainties of less than 2 mm, while no significant improvement was seen using B<sub>0</sub> field map correction</p> </abstract> … (more)
- Is Part Of:
- Acta oncologica. Volume 53:Number 8(2014)
- Journal:
- Acta oncologica
- Issue:
- Volume 53:Number 8(2014)
- Issue Display:
- Volume 53, Issue 8 (2014)
- Year:
- 2014
- Volume:
- 53
- Issue:
- 8
- Issue Sort Value:
- 2014-0053-0008-0000
- Page Start:
- 1073
- Page End:
- 1078
- Publication Date:
- 2014-08
- Subjects:
- Oncology -- Periodicals
Cancer -- Treatment -- Periodicals
616.992 - Journal URLs:
- http://informahealthcare.com/loi/onc ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/0284186X.2014.938831 ↗
- Languages:
- English
- ISSNs:
- 0284-186X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0641.705000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4119.xml