Acute angle closure: qualitative and quantitative evaluation of the anterior segment using anterior segment optical coherence tomography. (27th January 2014)
- Record Type:
- Journal Article
- Title:
- Acute angle closure: qualitative and quantitative evaluation of the anterior segment using anterior segment optical coherence tomography. (27th January 2014)
- Main Title:
- Acute angle closure: qualitative and quantitative evaluation of the anterior segment using anterior segment optical coherence tomography
- Authors:
- Moghimi, Sasan
Zandvakil, Narges
Vahedian, Zakieh
Mohammadi, Massood
Fakhraie, Ghasem
Coleman, Anne L
Lin, Shan C - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <sec id="ceo12285-sec-0001" sec-type="section"> <title>Background</title> <p>To evaluate different mechanisms of acute angle closure and to compare it with unaffected fellow eyes and primary angle closure suspects using anterior segment optical coherence tomography.</p> </sec> <sec id="ceo12285-sec-0002" sec-type="section"> <title>Design</title> <p>Prospective, cross‐sectional.</p> </sec> <sec id="ceo12285-sec-1002" sec-type="section"> <title>Participants</title> <p>116 eyes (76 patients) with angle closure disease were included.</p> </sec> <sec id="ceo12285-sec-0003" sec-type="section"> <title>Methods</title> <p>Eyes were categorized into three groups: (i) acute angle closure (40 eyes); (ii) fellow eyes of acute angle closure (40 eyes); and (iii) primary angle closure suspect (36 eyes). Complete ophthalmic examinations including gonioscopy, A‐scan biometry and anterior segment optical coherence tomography were performed.</p> </sec> <sec id="ceo12285-sec-0004" sec-type="section"> <title>Main Outcome Measure</title> <p>Based on the anterior segment optical coherence tomography images, four mechanisms of primary angle closure including pupil block, plateau iris configuration, thick peripheral iris roll and exaggerated lens vault were evaluated among the three subtypes of angle closure disease.</p> </sec> <sec id="ceo12285-sec-0005" sec-type="section"> <title>Results</title> <p>There was a statistically significant<abstract abstract-type="main"> <title>Abstract</title> <sec id="ceo12285-sec-0001" sec-type="section"> <title>Background</title> <p>To evaluate different mechanisms of acute angle closure and to compare it with unaffected fellow eyes and primary angle closure suspects using anterior segment optical coherence tomography.</p> </sec> <sec id="ceo12285-sec-0002" sec-type="section"> <title>Design</title> <p>Prospective, cross‐sectional.</p> </sec> <sec id="ceo12285-sec-1002" sec-type="section"> <title>Participants</title> <p>116 eyes (76 patients) with angle closure disease were included.</p> </sec> <sec id="ceo12285-sec-0003" sec-type="section"> <title>Methods</title> <p>Eyes were categorized into three groups: (i) acute angle closure (40 eyes); (ii) fellow eyes of acute angle closure (40 eyes); and (iii) primary angle closure suspect (36 eyes). Complete ophthalmic examinations including gonioscopy, A‐scan biometry and anterior segment optical coherence tomography were performed.</p> </sec> <sec id="ceo12285-sec-0004" sec-type="section"> <title>Main Outcome Measure</title> <p>Based on the anterior segment optical coherence tomography images, four mechanisms of primary angle closure including pupil block, plateau iris configuration, thick peripheral iris roll and exaggerated lens vault were evaluated among the three subtypes of angle closure disease.</p> </sec> <sec id="ceo12285-sec-0005" sec-type="section"> <title>Results</title> <p>There was a statistically significant difference in the mechanism of angle closure disease among the three groups (<italic>P</italic> &lt; 0.001). Although the majority of fellow and primary angle closure suspect eyes had pupil block mechanism (77.5% and 75%, respectively), only 37.5% of acute angle closure eyes had dominant pupil block mechanism. The percentage because of exaggerated lens vault was greatest in acute angle closure eyes (50%). Acute angle closure eyes had the shallowest anterior chamber depth (<italic>P</italic> &lt; 0.001), least iris curvature (<italic>P</italic> &lt; 0.001) and greatest lens vault (<italic>P</italic> = 0.003) compared with the other two groups.</p> </sec> <sec id="ceo12285-sec-0006" sec-type="section"> <title>Conclusions</title> <p>A statistically significant difference in the underlying primary angle closure mechanisms among acute angle closure eyes as compared with their fellow eyes and primary angle closure suspect may exist.</p> </sec> </abstract> … (more)
- Is Part Of:
- Clinical & experimental ophthalmology. Volume 42:Number 7(2014)
- Journal:
- Clinical & experimental ophthalmology
- Issue:
- Volume 42:Number 7(2014)
- Issue Display:
- Volume 42, Issue 7 (2014)
- Year:
- 2014
- Volume:
- 42
- Issue:
- 7
- Issue Sort Value:
- 2014-0042-0007-0000
- Page Start:
- 615
- Page End:
- 622
- Publication Date:
- 2014-01-27
- Subjects:
- Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=1442-6404&site=1 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ceo.12285 ↗
- Languages:
- English
- ISSNs:
- 1442-6404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.251920
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3120.xml