Transesophageal Echocardiography as the Sole Guidance for Occlusion of Patent Ductus Arteriosus using a Canine Ductal Occluder in Dogs. (16th July 2014)
- Record Type:
- Journal Article
- Title:
- Transesophageal Echocardiography as the Sole Guidance for Occlusion of Patent Ductus Arteriosus using a Canine Ductal Occluder in Dogs. (16th July 2014)
- Main Title:
- Transesophageal Echocardiography as the Sole Guidance for Occlusion of Patent Ductus Arteriosus using a Canine Ductal Occluder in Dogs
- Authors:
- Porciello, F.
Caivano, D.
Giorgi, M.E.
Knafelz, P.
Rishniw, M.
Moise, N.S.
Bufalari, A.
Fruganti, A.
Birettoni, F. - Abstract:
- <abstract abstract-type="main" id="jvim12401-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jvim12401-sec-0001" sec-type="section"> <title>Background</title> <p>Transcatheter occlusion of patent ductus arteriosus (PDA) is usually performed by fluoroscopy alone or together with transesophageal echocardiography (TEE). Transthoracic echocardiography (TTE) guidance has been used for deployment of Amplatz Canine Ductal Occluder (ACDO), but sometimes is limited by suboptimal acoustic windows. Transesophageal echocardiography can overcome such issues and provides higher image resolution at the level of the great vessels.</p> </sec> <sec id="jvim12401-sec-0002" sec-type="section"> <title>Objectives</title> <p>To determine if TEE without fluoroscopy could be used to successfully perform ductal occlusion for the treatment of PDA in dogs.</p> </sec> <sec id="jvim12401-sec-0003" sec-type="section"> <title>Animals</title> <p>Twenty client‐owned dogs with PDA.</p> </sec> <sec id="jvim12401-sec-0004" sec-type="section"> <title>Methods</title> <p>A prospective consecutive case series of PDA occlusion was performed using only TEE guidance. Dogs were positioned in right lateral recumbency and the TEE probe was positioned to visualize the descending aorta, PDA, and pulmonary artery. The guide wire, long introducer sheath, and ACDO were imaged by TEE to direct deployment.</p> </sec> <sec id="jvim12401-sec-0005" sec-type="section"> <title>Results</title> <p>Ductal<abstract abstract-type="main" id="jvim12401-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jvim12401-sec-0001" sec-type="section"> <title>Background</title> <p>Transcatheter occlusion of patent ductus arteriosus (PDA) is usually performed by fluoroscopy alone or together with transesophageal echocardiography (TEE). Transthoracic echocardiography (TTE) guidance has been used for deployment of Amplatz Canine Ductal Occluder (ACDO), but sometimes is limited by suboptimal acoustic windows. Transesophageal echocardiography can overcome such issues and provides higher image resolution at the level of the great vessels.</p> </sec> <sec id="jvim12401-sec-0002" sec-type="section"> <title>Objectives</title> <p>To determine if TEE without fluoroscopy could be used to successfully perform ductal occlusion for the treatment of PDA in dogs.</p> </sec> <sec id="jvim12401-sec-0003" sec-type="section"> <title>Animals</title> <p>Twenty client‐owned dogs with PDA.</p> </sec> <sec id="jvim12401-sec-0004" sec-type="section"> <title>Methods</title> <p>A prospective consecutive case series of PDA occlusion was performed using only TEE guidance. Dogs were positioned in right lateral recumbency and the TEE probe was positioned to visualize the descending aorta, PDA, and pulmonary artery. The guide wire, long introducer sheath, and ACDO were imaged by TEE to direct deployment.</p> </sec> <sec id="jvim12401-sec-0005" sec-type="section"> <title>Results</title> <p>Ductal occlusion was performed successfully without need for fluoroscopy and without complications in 19 dogs. One dog required a second larger ACDO because of embolization of the first device 18 hours after positioning.</p> </sec> <sec id="jvim12401-sec-0006" sec-type="section"> <title>Conclusions and Clinical Importance</title> <p>We have demonstrated that TEE monitoring without concurrent fluoroscopy can guide each step of transcatheter ACDO embolization thereby providing an alternate method of visualization for this procedure. Use of TEE alone can reduce radiation exposure or is an option when fluoroscopy is not available, and, therefore, should be evaluated in a larger case series to better assess procedural failure rates.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of veterinary internal medicine. Volume 28:Number 5(2014:Sep./Oct.)
- Journal:
- Journal of veterinary internal medicine
- Issue:
- Volume 28:Number 5(2014:Sep./Oct.)
- Issue Display:
- Volume 28, Issue 5 (2014)
- Year:
- 2014
- Volume:
- 28
- Issue:
- 5
- Issue Sort Value:
- 2014-0028-0005-0000
- Page Start:
- 1504
- Page End:
- 1512
- Publication Date:
- 2014-07-16
- Subjects:
- Veterinary medicine -- Periodicals
636.0896 - Journal URLs:
- http://www.jvetintmed.org ↗
http://www3.interscience.wiley.com/journal/118902531/home ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jvim.12401 ↗
- Languages:
- English
- ISSNs:
- 0891-6640
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5072.365000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3023.xml