Novel Stereoselective High‐Performance Liquid Chromatographic Method for Simultaneous Determination of Guaifenesin and Ketorolac Enantiomers in Human Plasma. Issue 10 (8th July 2014)
- Record Type:
- Journal Article
- Title:
- Novel Stereoselective High‐Performance Liquid Chromatographic Method for Simultaneous Determination of Guaifenesin and Ketorolac Enantiomers in Human Plasma. Issue 10 (8th July 2014)
- Main Title:
- Novel Stereoselective High‐Performance Liquid Chromatographic Method for Simultaneous Determination of Guaifenesin and Ketorolac Enantiomers in Human Plasma
- Authors:
- Maher, Hadir M.
Al‐Taweel, Shorog M.
Alshehri, Mona M.
Alzoman, Nourah Z. - Abstract:
- <abstract abstract-type="main"> <title>ABSTRACT</title> <p>A novel method was developed for the simultaneous determination of guaifenesin (GUA) and ketorolac tromethamine (KET) enantiomers in plasma samples. Since GUA probably increases the absorption of coadministered drugs (e.g., KET), it would be extremely important to monitor KET plasma levels for the purpose of dose adjustment with a subsequent decrease in the side effects. Enantiomeric resolution was achieved on a polysaccharide‐based chiral stationary phase, amylose‐2, as a chiral selector under the normal phase (NP) mode and using ornidazole (ORN) as internal standard. This innovative method has the advantage of the ease and reliability of sample preparation for plasma samples. Sample clean‐up was based on simply using methanol for protein precipitation followed by direct extraction of drug residues using ethanol. Both GUA and KET enantiomers were separated using an isocratic mobile phase composed of hexane/isopropanol/trifluoroacetic acid, 85:15:0.05 v/v/v. Peak area ratios were linear over the range 0.05–20 µg/mL for the four enantiomers <italic>S</italic> (+) GUA, <italic>R</italic> (–) GUA, <italic>R</italic> (+) KET, and <italic>S</italic> (–) KET. The method was fully validated according to the International Conference on Harmonization (ICH) guidelines in terms of system suitability, specificity, accuracy, precision, robustness, and solution stability. Finally, this procedure was innovative to apply the<abstract abstract-type="main"> <title>ABSTRACT</title> <p>A novel method was developed for the simultaneous determination of guaifenesin (GUA) and ketorolac tromethamine (KET) enantiomers in plasma samples. Since GUA probably increases the absorption of coadministered drugs (e.g., KET), it would be extremely important to monitor KET plasma levels for the purpose of dose adjustment with a subsequent decrease in the side effects. Enantiomeric resolution was achieved on a polysaccharide‐based chiral stationary phase, amylose‐2, as a chiral selector under the normal phase (NP) mode and using ornidazole (ORN) as internal standard. This innovative method has the advantage of the ease and reliability of sample preparation for plasma samples. Sample clean‐up was based on simply using methanol for protein precipitation followed by direct extraction of drug residues using ethanol. Both GUA and KET enantiomers were separated using an isocratic mobile phase composed of hexane/isopropanol/trifluoroacetic acid, 85:15:0.05 v/v/v. Peak area ratios were linear over the range 0.05–20 µg/mL for the four enantiomers <italic>S</italic> (+) GUA, <italic>R</italic> (–) GUA, <italic>R</italic> (+) KET, and <italic>S</italic> (–) KET. The method was fully validated according to the International Conference on Harmonization (ICH) guidelines in terms of system suitability, specificity, accuracy, precision, robustness, and solution stability. Finally, this procedure was innovative to apply the rationale of developing a chiral high‐performance <named-content content-type="chemicalTechnology" xlink:type="simple" xmlns:xlink="http://www.w3.org/1999/xlink">liquid chromatography</named-content> (HPLC) procedure for the simultaneous quantitative analysis of drug isomers in clinical samples. <italic>Chirality 26:629–639, 2014</italic>. © 2014 Wiley Periodicals, Inc.</p> </abstract> … (more)
- Is Part Of:
- Chirality. Volume 26:Issue 10(2014:Oct.)
- Journal:
- Chirality
- Issue:
- Volume 26:Issue 10(2014:Oct.)
- Issue Display:
- Volume 26, Issue 10 (2014)
- Year:
- 2014
- Volume:
- 26
- Issue:
- 10
- Issue Sort Value:
- 2014-0026-0010-0000
- Page Start:
- 629
- Page End:
- 639
- Publication Date:
- 2014-07-08
- Subjects:
- Chirality -- Periodicals
Pharmaceutical chemistry -- Periodicals
541.22 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1520-636X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/chir.22354 ↗
- Languages:
- English
- ISSNs:
- 0899-0042
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3181.124450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4117.xml