Motion‐compensated compressed sensing for dynamic contrast‐enhanced MRI using regional spatiotemporal sparsity and region tracking: Block low‐rank sparsity with motion‐guidance (BLOSM). Issue 4 (18th November 2013)
- Record Type:
- Journal Article
- Title:
- Motion‐compensated compressed sensing for dynamic contrast‐enhanced MRI using regional spatiotemporal sparsity and region tracking: Block low‐rank sparsity with motion‐guidance (BLOSM). Issue 4 (18th November 2013)
- Main Title:
- Motion‐compensated compressed sensing for dynamic contrast‐enhanced MRI using regional spatiotemporal sparsity and region tracking: Block low‐rank sparsity with motion‐guidance (BLOSM)
- Authors:
- Chen, Xiao
Salerno, Michael
Yang, Yang
Epstein, Frederick H. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="mrm25018-sec-0001" sec-type="section"> <title>Purpose</title> <p>Dynamic contrast‐enhanced MRI of the heart is well‐suited for acceleration with compressed sensing (CS) due to its spatiotemporal sparsity; however, respiratory motion can degrade sparsity and lead to image artifacts. We sought to develop a motion‐compensated CS method for this application.</p> </sec> <sec id="mrm25018-sec-0002" sec-type="section"> <title>Methods</title> <p>A new method, Block LOw‐rank Sparsity with Motion‐guidance (BLOSM), was developed to accelerate first‐pass cardiac MRI, even in the presence of respiratory motion. This method divides the images into regions, tracks the regions through time, and applies matrix low‐rank sparsity to the tracked regions. BLOSM was evaluated using computer simulations and first‐pass cardiac datasets from human subjects. Using rate‐4 undersampling, BLOSM was compared with other CS methods such as k‐t SLR that uses matrix low‐rank sparsity applied to the whole image dataset, with and without motion tracking, and to k‐t FOCUSS with motion estimation and compensation that uses spatial and temporal‐frequency sparsity.</p> </sec> <sec id="mrm25018-sec-0003" sec-type="section"> <title>Results</title> <p>BLOSM was qualitatively shown to reduce respiratory artifact compared with other methods. Quantitatively, using root mean squared error and the structural similarity index,<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="mrm25018-sec-0001" sec-type="section"> <title>Purpose</title> <p>Dynamic contrast‐enhanced MRI of the heart is well‐suited for acceleration with compressed sensing (CS) due to its spatiotemporal sparsity; however, respiratory motion can degrade sparsity and lead to image artifacts. We sought to develop a motion‐compensated CS method for this application.</p> </sec> <sec id="mrm25018-sec-0002" sec-type="section"> <title>Methods</title> <p>A new method, Block LOw‐rank Sparsity with Motion‐guidance (BLOSM), was developed to accelerate first‐pass cardiac MRI, even in the presence of respiratory motion. This method divides the images into regions, tracks the regions through time, and applies matrix low‐rank sparsity to the tracked regions. BLOSM was evaluated using computer simulations and first‐pass cardiac datasets from human subjects. Using rate‐4 undersampling, BLOSM was compared with other CS methods such as k‐t SLR that uses matrix low‐rank sparsity applied to the whole image dataset, with and without motion tracking, and to k‐t FOCUSS with motion estimation and compensation that uses spatial and temporal‐frequency sparsity.</p> </sec> <sec id="mrm25018-sec-0003" sec-type="section"> <title>Results</title> <p>BLOSM was qualitatively shown to reduce respiratory artifact compared with other methods. Quantitatively, using root mean squared error and the structural similarity index, BLOSM was superior to other methods.</p> </sec> <sec id="mrm25018-sec-0004" sec-type="section"> <title>Conclusion</title> <p>BLOSM, which exploits regional low‐rank structure and uses region tracking for motion compensation, provides improved image quality for CS‐accelerated first‐pass cardiac MRI. Magn Reson Med 72:1028–1038, 2014. © 2013 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 72:Issue 4(2014:Oct.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 72:Issue 4(2014:Oct.)
- Issue Display:
- Volume 72, Issue 4 (2014)
- Year:
- 2014
- Volume:
- 72
- Issue:
- 4
- Issue Sort Value:
- 2014-0072-0004-0000
- Page Start:
- 1028
- Page End:
- 1038
- Publication Date:
- 2013-11-18
- Subjects:
- Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.25018 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3383.xml