Comparison of Two Non-mydriatic Fundus Cameras to Obtain Retinal Arterio-venous Ratio. (October 2014)
- Record Type:
- Journal Article
- Title:
- Comparison of Two Non-mydriatic Fundus Cameras to Obtain Retinal Arterio-venous Ratio. (October 2014)
- Main Title:
- Comparison of Two Non-mydriatic Fundus Cameras to Obtain Retinal Arterio-venous Ratio
- Authors:
- Jürgens, Clemens
Ittermann, Till
Völzke, Henry
Tost, Frank - Abstract:
- <abstract> <title>Abstract</title> <p> <italic>Purpose</italic>: To analyze device-dependent variability of two non-mydriatic fundus cameras to obtain arterio-venous ratio (AVR), central retinal arteriolar equivalent (CRAE), and central retinal venular equivalent (CRVE) in static vessel analysis (SVA).</p> <p> <italic>Methods</italic>: We examined 53 participants (29 men, 24 women; median age 46 years) of the Study of Health in Pomerania (SHIP). We took 45° optic-disc-centered fundus images of the right eye with two different non-mydriatic fundus cameras. The first photograph was obtained from the TRC-NW 200, the second from the OCT 2000 (both Topcon Corporation, Tokyo, Japan). One experienced grader graded image quality from 1 "ideal quality" to 5 "not analyzable" and determined AVR, CRAE, and CRVE with the software Vesselmap3 (Imedos, Jena, Germany).</p> <p> <italic>Results</italic>: Average image quality was 1.8 for the TRC-NW 200 and 1.6 for the OCT 2000. AVR could not be determined in 5 images of the TRC-NW 200 due to low image quality, while six images of the OCT 2000 were not analyzable. The difference between AVR taken from two different non-mydriatic cameras was 0.01 ± 0.03 in Bland-Altman plots. The difference between CRAE was 0.17 ± 10.15 and between CRVE was −2.32 ± 11.76.</p> <p> <italic>Conclusions</italic>: The two different non-mydriatic cameras showed good agreement with respect to image quality. When using the same reading software, AVR, CRAE, and CRVE<abstract> <title>Abstract</title> <p> <italic>Purpose</italic>: To analyze device-dependent variability of two non-mydriatic fundus cameras to obtain arterio-venous ratio (AVR), central retinal arteriolar equivalent (CRAE), and central retinal venular equivalent (CRVE) in static vessel analysis (SVA).</p> <p> <italic>Methods</italic>: We examined 53 participants (29 men, 24 women; median age 46 years) of the Study of Health in Pomerania (SHIP). We took 45° optic-disc-centered fundus images of the right eye with two different non-mydriatic fundus cameras. The first photograph was obtained from the TRC-NW 200, the second from the OCT 2000 (both Topcon Corporation, Tokyo, Japan). One experienced grader graded image quality from 1 "ideal quality" to 5 "not analyzable" and determined AVR, CRAE, and CRVE with the software Vesselmap3 (Imedos, Jena, Germany).</p> <p> <italic>Results</italic>: Average image quality was 1.8 for the TRC-NW 200 and 1.6 for the OCT 2000. AVR could not be determined in 5 images of the TRC-NW 200 due to low image quality, while six images of the OCT 2000 were not analyzable. The difference between AVR taken from two different non-mydriatic cameras was 0.01 ± 0.03 in Bland-Altman plots. The difference between CRAE was 0.17 ± 10.15 and between CRVE was −2.32 ± 11.76.</p> <p> <italic>Conclusions</italic>: The two different non-mydriatic cameras showed good agreement with respect to image quality. When using the same reading software, AVR, CRAE, and CRVE agreed well. Thus, funduscopy and SVA seem to be robust against inter-device variability. As a result, device dependency can remain unconsidered in follow-up examinations with different technical equipment. However, variability might impact more with devices from different manufacturers.</p> </abstract> … (more)
- Is Part Of:
- Ophthalmic epidemiology. Volume 21:Number 5(2014)
- Journal:
- Ophthalmic epidemiology
- Issue:
- Volume 21:Number 5(2014)
- Issue Display:
- Volume 21, Issue 5 (2014)
- Year:
- 2014
- Volume:
- 21
- Issue:
- 5
- Issue Sort Value:
- 2014-0021-0005-0000
- Page Start:
- 333
- Page End:
- 338
- Publication Date:
- 2014-10
- Subjects:
- Blindness -- Prevention -- Periodicals
Eye -- Diseases -- Epidemiology -- Periodicals
Ophthalmology -- Periodicals
614.5997 - Journal URLs:
- http://informahealthcare.com/loi/ope ↗
http://informahealthcare.com ↗
http://www.tandf.co.uk/journals/titles/09286586.asp ↗ - DOI:
- 10.3109/09286586.2014.949352 ↗
- Languages:
- English
- ISSNs:
- 0928-6586
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6270.880000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3500.xml