Volatile organic compounds in fourteen U.S. retail stores. (15th March 2014)
- Record Type:
- Journal Article
- Title:
- Volatile organic compounds in fourteen U.S. retail stores. (15th March 2014)
- Main Title:
- Volatile organic compounds in fourteen U.S. retail stores
- Authors:
- Nirlo, E. L.
Crain, N.
Corsi, R. L.
Siegel, J. A. - Abstract:
- <abstract abstract-type="main" id="ina12101-abs-0001"> <title>Abstract</title> <p>Retail buildings have a potential for both short‐term (customer) and long‐term (occupational) exposure to indoor pollutants. However, little is known about volatile organic compound (VOC) concentrations in the retail sector and influencing factors, such as ventilation, in‐store activities, and store type. We measured VOC concentrations and ventilation rates in 14 retail stores in Texas and Pennsylvania. With the exception of formaldehyde and acetaldehyde, VOCs were present in retail stores at concentrations well below health guidelines. Indoor formaldehyde concentrations ranged from 4.6 ppb to 67 ppb. The two mid‐sized grocery stores in the sample had the highest levels of ethanol and acetaldehyde, with concentrations up to 2.6 ppm and 92 ppb, respectively, possibly due to the preparation of dough and baking activities. Indoor‐to‐outdoor concentration ratios indicated that indoor sources were the main contributors to indoor VOC concentrations for the majority of compounds. There was no strong correlation between ventilation and VOC concentrations across all stores. However, increasing the air exchange rates at two stores led to lower indoor VOC concentrations, suggesting that ventilation can be used to reduce concentrations for some specific stores.</p> </abstract>
- Is Part Of:
- Indoor air. Volume 24:Number 5(2014:Oct.)
- Journal:
- Indoor air
- Issue:
- Volume 24:Number 5(2014:Oct.)
- Issue Display:
- Volume 24, Issue 5 (2014)
- Year:
- 2014
- Volume:
- 24
- Issue:
- 5
- Issue Sort Value:
- 2014-0024-0005-0000
- Page Start:
- 484
- Page End:
- 494
- Publication Date:
- 2014-03-15
- Subjects:
- Indoor air pollution -- Periodicals
Sick building syndrome -- Periodicals
Ventilation -- Periodicals
613.5 - Journal URLs:
- http://www.blackwell-synergy.com/loi/ina ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1600-0668 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ina.12101 ↗
- Languages:
- English
- ISSNs:
- 0905-6947
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4438.046530
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3077.xml