New Universal Strain Software Accurately Assesses Cardiac Systolic and Diastolic Function Using Speckle Tracking Echocardiography. Issue 8 (22nd January 2014)
- Record Type:
- Journal Article
- Title:
- New Universal Strain Software Accurately Assesses Cardiac Systolic and Diastolic Function Using Speckle Tracking Echocardiography. Issue 8 (22nd January 2014)
- Main Title:
- New Universal Strain Software Accurately Assesses Cardiac Systolic and Diastolic Function Using Speckle Tracking Echocardiography
- Authors:
- Kolias, Theodore J.
Hagan, Peter G.
Chetcuti, Stanley J.
Eberhart, Diane L.
Kline, Nicole M.
Lucas, Sean D.
Hamilton, James D. - Abstract:
- <abstract abstract-type="main" id="echo12512-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="echo12512-sec-0001" sec-type="section"> <title>Background</title> <p>We have developed new universal strain software (USS) that can be used to perform speckle tracking of any Digital Imaging and Communications in Medicine (DICOM) image, regardless of the ultrasound system used to obtain it.</p> </sec> <sec id="echo12512-sec-0002" sec-type="section"> <title>Methods</title> <p>Fifty patients prospectively underwent echocardiography immediately prior to cardiac catheterization. Biplane peak global longitudinal strain (GLS), peak systolic longitudinal strain rate (SSR), peak early diastolic longitudinal strain rate (DSR), and peak early diastolic circumferential strain rate (DCSR) were determined using conventional strain software (CSS) that uses raw data, and using the new USS applied to DICOM images.</p> </sec> <sec id="echo12512-sec-0003" sec-type="section"> <title>Results</title> <p>Universal strain software correlated with CSS for GLS (r = 0.78, P &lt; 0.001), SSR (r = 0.78, P &lt; 0.001), DSR (r = 0.54, P &lt; 0.001), and DCSR (r = 0.43, P = 0.019). GLS and SSR using USS correlated with left ventricular ejection fraction (LVEF) (r = −0.67 and −0.71, respectively) as well as using CSS (r = −0.66 and −0.71). Patients with diastolic dysfunction had significantly lower DSR (0.61 vs. 0.87/sec, P = 0.02) and DCSR (0.89 vs. 1.23/sec, P = 0.03), and less negative<abstract abstract-type="main" id="echo12512-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="echo12512-sec-0001" sec-type="section"> <title>Background</title> <p>We have developed new universal strain software (USS) that can be used to perform speckle tracking of any Digital Imaging and Communications in Medicine (DICOM) image, regardless of the ultrasound system used to obtain it.</p> </sec> <sec id="echo12512-sec-0002" sec-type="section"> <title>Methods</title> <p>Fifty patients prospectively underwent echocardiography immediately prior to cardiac catheterization. Biplane peak global longitudinal strain (GLS), peak systolic longitudinal strain rate (SSR), peak early diastolic longitudinal strain rate (DSR), and peak early diastolic circumferential strain rate (DCSR) were determined using conventional strain software (CSS) that uses raw data, and using the new USS applied to DICOM images.</p> </sec> <sec id="echo12512-sec-0003" sec-type="section"> <title>Results</title> <p>Universal strain software correlated with CSS for GLS (r = 0.78, P &lt; 0.001), SSR (r = 0.78, P &lt; 0.001), DSR (r = 0.54, P &lt; 0.001), and DCSR (r = 0.43, P = 0.019). GLS and SSR using USS correlated with left ventricular ejection fraction (LVEF) (r = −0.67 and −0.71, respectively) as well as using CSS (r = −0.66 and −0.71). Patients with diastolic dysfunction had significantly lower DSR (0.61 vs. 0.87/sec, P = 0.02) and DCSR (0.89 vs. 1.23/sec, P = 0.03), and less negative GLS (−10.8 vs. −16.1%, P = 0.002) using USS in all patients, as well as among those with LVEF ≥ 50%. Receiver‐operating characteristic (ROC) analysis for detection of diastolic dysfunction revealed a sensitivity and specificity of 82% and 83% for DCSR &lt; 1.09/sec (area under the curve [AUC = 0.80]) and 85% and 83% for GLS &gt; −13.7% (AUC = 0.84) using USS.</p> </sec> <sec id="echo12512-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Universal strain software can be used to accurately assess LV systolic and diastolic function using speckle tracking echocardiography.</p> </sec> </abstract> … (more)
- Is Part Of:
- Echocardiography. Volume 31:Issue 8(2014)
- Journal:
- Echocardiography
- Issue:
- Volume 31:Issue 8(2014)
- Issue Display:
- Volume 31, Issue 8 (2014)
- Year:
- 2014
- Volume:
- 31
- Issue:
- 8
- Issue Sort Value:
- 2014-0031-0008-0000
- Page Start:
- 947
- Page End:
- 955
- Publication Date:
- 2014-01-22
- Subjects:
- Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.12512 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4279.xml