Feasibility of Myocardial Performance Index for Evaluation of Left Ventricular Function during Dobutamine Stress Echocardiography before and after Coronary Artery Bypass Grafting. Issue 8 (20th December 2013)
- Record Type:
- Journal Article
- Title:
- Feasibility of Myocardial Performance Index for Evaluation of Left Ventricular Function during Dobutamine Stress Echocardiography before and after Coronary Artery Bypass Grafting. Issue 8 (20th December 2013)
- Main Title:
- Feasibility of Myocardial Performance Index for Evaluation of Left Ventricular Function during Dobutamine Stress Echocardiography before and after Coronary Artery Bypass Grafting
- Authors:
- Hashemi, Nashmil
Samad, Bassem A.
Hedman, Anders
Brodin, Lars‐Åke
Alam, Mahbubul - Abstract:
- <abstract abstract-type="main" id="echo12488-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="echo12488-sec-0001" sec-type="section"> <title>Aims</title> <p>Myocardial performance index (MPI) is a measure of combined systolic and diastolic myocardial function. In patients with coronary artery disease (CAD) an increase in MPI is consistent with myocardial dysfunction. The objectives of this study were to characterize the changes in MPI after coronary artery bypass graft (CABG) at rest and at peak dobutamine stress echocardiography (DSE).</p> </sec> <sec id="echo12488-sec-0002" sec-type="section"> <title>Methods and Results</title> <p>Thirty‐six patients diagnosed with CAD and accepted for CABG were studied by standard echocardiography and DSE 1 month prior and 3 month after CABG. The MPI was calculated using pulsed‐wave tissue Doppler imaging (PW‐TDI) of the left ventricular (LV) wall‐motion velocity. At baseline, ejection fraction (EF; 42.7 ± 8%) and wall‐motion score index (WMSI; 1.1 ± 0.2) were impaired at rest as well as at peak DSE (EF; 49.2 ± 9 and WMSI 1.4 ± 0.2). MPI was prolonged both at rest (0.61 ± 0.13) and at peak DSE (0.78 ± 0.16). After CABG, EF and WMSI did not improve at rest (43.7 ± 8% and 1.1 ± 0.2, respectively). On the other hand, MPI improved substantially both at rest (0.45 ± 0.08; P &lt; 0.001) and at peak DSE (0.56 ± 0.1; P &lt; 0.001). At peak DSE an improvement of EF (54.2 ± 9; P &lt; 0.05) and WMSI (1.1 ± 0.16;<abstract abstract-type="main" id="echo12488-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="echo12488-sec-0001" sec-type="section"> <title>Aims</title> <p>Myocardial performance index (MPI) is a measure of combined systolic and diastolic myocardial function. In patients with coronary artery disease (CAD) an increase in MPI is consistent with myocardial dysfunction. The objectives of this study were to characterize the changes in MPI after coronary artery bypass graft (CABG) at rest and at peak dobutamine stress echocardiography (DSE).</p> </sec> <sec id="echo12488-sec-0002" sec-type="section"> <title>Methods and Results</title> <p>Thirty‐six patients diagnosed with CAD and accepted for CABG were studied by standard echocardiography and DSE 1 month prior and 3 month after CABG. The MPI was calculated using pulsed‐wave tissue Doppler imaging (PW‐TDI) of the left ventricular (LV) wall‐motion velocity. At baseline, ejection fraction (EF; 42.7 ± 8%) and wall‐motion score index (WMSI; 1.1 ± 0.2) were impaired at rest as well as at peak DSE (EF; 49.2 ± 9 and WMSI 1.4 ± 0.2). MPI was prolonged both at rest (0.61 ± 0.13) and at peak DSE (0.78 ± 0.16). After CABG, EF and WMSI did not improve at rest (43.7 ± 8% and 1.1 ± 0.2, respectively). On the other hand, MPI improved substantially both at rest (0.45 ± 0.08; P &lt; 0.001) and at peak DSE (0.56 ± 0.1; P &lt; 0.001). At peak DSE an improvement of EF (54.2 ± 9; P &lt; 0.05) and WMSI (1.1 ± 0.16; P &lt; 0.001) was seen as well.</p> </sec> <sec id="echo12488-sec-0003" sec-type="section"> <title>Conclusion</title> <p>Myocardial performance index shows significant improvement after CABG in patients with CAD both at rest and peak DSE and appears to be a sensitive measure of myocardial function.</p> </sec> </abstract> … (more)
- Is Part Of:
- Echocardiography. Volume 31:Issue 8(2014)
- Journal:
- Echocardiography
- Issue:
- Volume 31:Issue 8(2014)
- Issue Display:
- Volume 31, Issue 8 (2014)
- Year:
- 2014
- Volume:
- 31
- Issue:
- 8
- Issue Sort Value:
- 2014-0031-0008-0000
- Page Start:
- 989
- Page End:
- 995
- Publication Date:
- 2013-12-20
- Subjects:
- Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.12488 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4279.xml