Modeling of porous scaffold deformation induced by medium perfusion. Issue 4 (21st November 2013)
- Record Type:
- Journal Article
- Title:
- Modeling of porous scaffold deformation induced by medium perfusion. Issue 4 (21st November 2013)
- Main Title:
- Modeling of porous scaffold deformation induced by medium perfusion
- Authors:
- Podichetty, Jagdeep T.
Madihally, Sundararajan V. - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <p>In this study, we tested the possibility of calculating permeability of porous scaffolds utilized in soft tissue engineering using pore size and shape. We validated the results using experimental measured pressure drop and simulations with the inclusion of structural deformation. We prepared Polycaprolactone (PCL) and Chitosan–Gelatin (CG) scaffolds by salt leaching and freeze drying technique, respectively. Micrographs were assessed for pore characteristics and mechanical properties. Porosity for both scaffolds was nearly same but the permeability varied 10‐fold. Elastic moduli were 600 and 9 kPa for PCL and CG scaffolds, respectively, while Poisson's ratio was 0.3 for PCL scaffolds and ∼1.0 for CG scaffolds. A flow‐through bioreactor accommodating a 10 cm diameter and 0.2 cm thick scaffold was used to determine the pressure‐drop at various flow rates. Additionally, computational fluid dynamic (CFD) simulations were performed by coupling fluid flow, described by Brinkman equation, with structural mechanics using a dynamic mesh. The experimentally obtained pressure drop matched the simulation results of PCL scaffolds. Simulations were extended to a broad range of permeabilities (10<sup>−10</sup> m<sup>2</sup> to 10<sup>−14</sup> m<sup>2</sup>), elastic moduli (10–100, 000 kPa) and Poisson's ratio (0.1–0.49). The results showed significant deviation in pressure drop due to scaffold deformation compared to rigid<abstract abstract-type="main"> <title>Abstract</title> <p>In this study, we tested the possibility of calculating permeability of porous scaffolds utilized in soft tissue engineering using pore size and shape. We validated the results using experimental measured pressure drop and simulations with the inclusion of structural deformation. We prepared Polycaprolactone (PCL) and Chitosan–Gelatin (CG) scaffolds by salt leaching and freeze drying technique, respectively. Micrographs were assessed for pore characteristics and mechanical properties. Porosity for both scaffolds was nearly same but the permeability varied 10‐fold. Elastic moduli were 600 and 9 kPa for PCL and CG scaffolds, respectively, while Poisson's ratio was 0.3 for PCL scaffolds and ∼1.0 for CG scaffolds. A flow‐through bioreactor accommodating a 10 cm diameter and 0.2 cm thick scaffold was used to determine the pressure‐drop at various flow rates. Additionally, computational fluid dynamic (CFD) simulations were performed by coupling fluid flow, described by Brinkman equation, with structural mechanics using a dynamic mesh. The experimentally obtained pressure drop matched the simulation results of PCL scaffolds. Simulations were extended to a broad range of permeabilities (10<sup>−10</sup> m<sup>2</sup> to 10<sup>−14</sup> m<sup>2</sup>), elastic moduli (10–100, 000 kPa) and Poisson's ratio (0.1–0.49). The results showed significant deviation in pressure drop due to scaffold deformation compared to rigid scaffold at permeabilities near healthy tissues. Also, considering the scaffold as a nonrigid structure altered the shear stress profile. In summary, scaffold permeability can be calculated using scaffold pore characteristics and deformation could be predicted using CFD simulation. These relationships could potentially be used in monitoring tissue regeneration noninvasively via pressure drop. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 102B: 737–748, 2014.</p> </abstract> … (more)
- Is Part Of:
- Journal of biomedical materials research. Volume 102:Issue 4(2014:May)
- Journal:
- Journal of biomedical materials research
- Issue:
- Volume 102:Issue 4(2014:May)
- Issue Display:
- Volume 102, Issue 4 (2014)
- Year:
- 2014
- Volume:
- 102
- Issue:
- 4
- Issue Sort Value:
- 2014-0102-0004-0000
- Page Start:
- 737
- Page End:
- 748
- Publication Date:
- 2013-11-21
- Subjects:
- Biomedical materials -- Periodicals
610.28 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jbm.b.33054 ↗
- Languages:
- English
- ISSNs:
- 1552-4973
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.725000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3551.xml