Spontaneous and Adenosine‐Induced Pulmonary Vein Reconnection After Cryoballoon Ablation with the Second‐Generation Device. (2nd May 2014)
- Record Type:
- Journal Article
- Title:
- Spontaneous and Adenosine‐Induced Pulmonary Vein Reconnection After Cryoballoon Ablation with the Second‐Generation Device. (2nd May 2014)
- Main Title:
- Spontaneous and Adenosine‐Induced Pulmonary Vein Reconnection After Cryoballoon Ablation with the Second‐Generation Device
- Authors:
- CICONTE, GIUSEPPE
CHIERCHIA, GIAN‐BATTISTA
DE ASMUNDIS, CARLO
SIEIRA, JUAN
CONTE, GIULIO
JULIÁ, JUSTO
DI GIOVANNI, GIACOMO
WAUTERS, KRISTEL
BALTOGIANNIS, GIANNIS
SAITOH, YUKIO
MUGNAI, GIACOMO
CATANZARITI, DOMENICO
TONDO, CLAUDIO
BRUGADA, PEDRO - Abstract:
- <abstract abstract-type="main"> <title>Second‐generation Cryoballoon Ablation and Pulmonary Vein Reconnections</title> <sec id="jce12421-sec-0010" sec-type="section"> <title>Introduction</title> <p>Longer observational time and adenosine challenge have proven to be able to detect pulmonary vein (PV) reconnections. The aim of this study was to assess incidence of spontaneous and adenosine‐induced PV reconnection after ablation with second‐generation cryoballoon (CB‐Adv).</p> </sec> <sec id="jce12421-sec-0020" sec-type="section"> <title>Methods and Results</title> <p>Fifty consecutive patients (76% male, mean age 60.5 ± 11.9 years) having undergone PV isolation (PVI) using the CB‐Adv were enrolled. After isolation, reconnections were evaluated using the Achieve catheter over 30 minutes observation and adenosine administration during isoproterenol infusion (adenosine challenge). Among 200 PVs, isolation was achieved in 190 (95%) during the first application. Lower nadir temperature and longer rewarming time were associated with successful PVI (P = 0.02 and 0.04). Spontaneous (4 veins) and adenosine‐induced (4 veins) PV reconnections occurred in the 4% of initially isolated veins (8 veins) in 6 patients (12%). At receiver–operator curve analysis, nadir temperature &lt;–51 °C and rewarming time &gt;28 seconds identified absence of reconnections (sensitivity 100% and 87%, area under the curve 0.75 and 0.72). Patients with right‐sided early branching frequently experienced<abstract abstract-type="main"> <title>Second‐generation Cryoballoon Ablation and Pulmonary Vein Reconnections</title> <sec id="jce12421-sec-0010" sec-type="section"> <title>Introduction</title> <p>Longer observational time and adenosine challenge have proven to be able to detect pulmonary vein (PV) reconnections. The aim of this study was to assess incidence of spontaneous and adenosine‐induced PV reconnection after ablation with second‐generation cryoballoon (CB‐Adv).</p> </sec> <sec id="jce12421-sec-0020" sec-type="section"> <title>Methods and Results</title> <p>Fifty consecutive patients (76% male, mean age 60.5 ± 11.9 years) having undergone PV isolation (PVI) using the CB‐Adv were enrolled. After isolation, reconnections were evaluated using the Achieve catheter over 30 minutes observation and adenosine administration during isoproterenol infusion (adenosine challenge). Among 200 PVs, isolation was achieved in 190 (95%) during the first application. Lower nadir temperature and longer rewarming time were associated with successful PVI (P = 0.02 and 0.04). Spontaneous (4 veins) and adenosine‐induced (4 veins) PV reconnections occurred in the 4% of initially isolated veins (8 veins) in 6 patients (12%). At receiver–operator curve analysis, nadir temperature &lt;–51 °C and rewarming time &gt;28 seconds identified absence of reconnections (sensitivity 100% and 87%, area under the curve 0.75 and 0.72). Patients with right‐sided early branching frequently experienced reconnections (P &lt; 0.01). After a mean follow‐up of 7.0 ± 1.7 months, 86% of patients were free from atrial fibrillation. None of those with PV reconnections experienced recurrences.</p> </sec> <sec id="jce12421-sec-0030" sec-type="section"> <title>Conclusions</title> <p>The incidence of spontaneous and adenosine‐induced PV reconnection following ablation with the novel CB‐Adv is very low occurring in 4% of initially isolated veins. Nadir temperature &lt;−51 °C and rewarming time &gt;28 seconds identified absence of acute reconnections, thus avoiding prolonged waiting time and adenosine challenge in such cases.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 25:Number 8(2014:Aug.)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 25:Number 8(2014:Aug.)
- Issue Display:
- Volume 25, Issue 8 (2014)
- Year:
- 2014
- Volume:
- 25
- Issue:
- 8
- Issue Sort Value:
- 2014-0025-0008-0000
- Page Start:
- 845
- Page End:
- 851
- Publication Date:
- 2014-05-02
- Subjects:
- Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.12421 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4301.xml