Therapeutic efficacy of long‐pulsed 755‐nm alexandrite laser for seborrheic keratoses. (2nd August 2013)
- Record Type:
- Journal Article
- Title:
- Therapeutic efficacy of long‐pulsed 755‐nm alexandrite laser for seborrheic keratoses. (2nd August 2013)
- Main Title:
- Therapeutic efficacy of long‐pulsed 755‐nm alexandrite laser for seborrheic keratoses
- Authors:
- Kim, Y.K.
Kim, D.‐Y.
Lee, S.J.
Chung, W.S.
Cho, S.B. - Abstract:
- <abstract abstract-type="main" id="jdv12231-abs-0001"> <title>Abstract</title> <sec id="jdv12231-sec-0001" sec-type="section"> <title>Background</title> <p>Both ablative and non‐ablative laser devices have been used for the cosmetic treatment of seborrheic keratoses.</p> </sec> <sec id="jdv12231-sec-0002" sec-type="section"> <title>Objectives</title> <p>We analysed treatment outcomes and adverse events in the treatment of seborrheic keratoses using a long‐pulsed 755‐nm alexandrite laser without colour enhancement.</p> </sec> <sec id="jdv12231-sec-0003" sec-type="section"> <title>Methods</title> <p>A total of 216 seborrheic keratoses in 13 patients were treated with one or three sessions of long‐pulsed 755‐nm alexandrite laser at 1‐month intervals. The lesions were treated with settings of 35 J/cm<sup>2</sup> using a 6‐mm spot size, a 3‐ms pulse width, and 1‐2 passes or until the appearance of fine bubbles on the irradiated lesions.</p> </sec> <sec id="jdv12231-sec-0004" sec-type="section"> <title>Results</title> <p>A total of 216 seborrheic keratoses were treated with a mean 1.1 ± 0.4 sessions of long‐pulsed 755‐nm alexandrite laser and achieved a mean objective improvement score of 3.4 ± 0.7. Morphologic factors significantly impacted the number of treatment sessions required; in particular, papular lesions seemed to require more repetitive long‐pulsed 755‐nm alexandrite laser treatments than macular lesions. However, objective improvement score was not affected by the type<abstract abstract-type="main" id="jdv12231-abs-0001"> <title>Abstract</title> <sec id="jdv12231-sec-0001" sec-type="section"> <title>Background</title> <p>Both ablative and non‐ablative laser devices have been used for the cosmetic treatment of seborrheic keratoses.</p> </sec> <sec id="jdv12231-sec-0002" sec-type="section"> <title>Objectives</title> <p>We analysed treatment outcomes and adverse events in the treatment of seborrheic keratoses using a long‐pulsed 755‐nm alexandrite laser without colour enhancement.</p> </sec> <sec id="jdv12231-sec-0003" sec-type="section"> <title>Methods</title> <p>A total of 216 seborrheic keratoses in 13 patients were treated with one or three sessions of long‐pulsed 755‐nm alexandrite laser at 1‐month intervals. The lesions were treated with settings of 35 J/cm<sup>2</sup> using a 6‐mm spot size, a 3‐ms pulse width, and 1‐2 passes or until the appearance of fine bubbles on the irradiated lesions.</p> </sec> <sec id="jdv12231-sec-0004" sec-type="section"> <title>Results</title> <p>A total of 216 seborrheic keratoses were treated with a mean 1.1 ± 0.4 sessions of long‐pulsed 755‐nm alexandrite laser and achieved a mean objective improvement score of 3.4 ± 0.7. Morphologic factors significantly impacted the number of treatment sessions required; in particular, papular lesions seemed to require more repetitive long‐pulsed 755‐nm alexandrite laser treatments than macular lesions. However, objective improvement score was not affected by the type of the seborrheic keratoses. The colour of seborrheic keratoses did not significantly affect the objective improvement score or required treatment sessions. Most of the lesions became crusted within a few days after the laser treatment and spontaneously peeled off within 7 days.</p> </sec> <sec id="jdv12231-sec-0005" sec-type="section"> <title>Conclusions</title> <p>The delivery of long‐pulsed, high fluence laser energy to seborrheic keratoses with protection of the epidermis by an integrated dynamic cooling device is an effective treatment with low risk of side‐effects, even in light‐coloured lesions with few target pigments.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of the European Academy of Dermatology and Venereology. Volume 28:Number 8(2014:Aug.)
- Journal:
- Journal of the European Academy of Dermatology and Venereology
- Issue:
- Volume 28:Number 8(2014:Aug.)
- Issue Display:
- Volume 28, Issue 8 (2014)
- Year:
- 2014
- Volume:
- 28
- Issue:
- 8
- Issue Sort Value:
- 2014-0028-0008-0000
- Page Start:
- 1007
- Page End:
- 1011
- Publication Date:
- 2013-08-02
- Subjects:
- Dermatology -- Periodicals
Sexually transmitted diseases -- Periodicals
616.5 - Journal URLs:
- https://onlinelibrary.wiley.com/journal/14683083 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=jdv ↗
http://www.sciencedirect.com/science/journal/09269959 ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0926-9959;screen=info;ECOIP ↗
http://www.blackwell-synergy.com/loi/jdv ↗ - DOI:
- 10.1111/jdv.12231 ↗
- Languages:
- English
- ISSNs:
- 0926-9959
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4741.624000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3536.xml