High‐strength poly(para‐phenylene) as an orthopedic biomaterial. Issue 9 (16th October 2013)
- Record Type:
- Journal Article
- Title:
- High‐strength poly(para‐phenylene) as an orthopedic biomaterial. Issue 9 (16th October 2013)
- Main Title:
- High‐strength poly(para‐phenylene) as an orthopedic biomaterial
- Authors:
- Frick, Carl P.
DiRienzo, Amy L.
Hoyt, Anthony J.
Safranski, David L.
Saed, Mohand
Losty, Eric J.
Yakacki, Christopher M. - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <p>Poly(<italic>para</italic>‐phenylene) (PPP) exhibits exceptional mechanical strength, stiffness, toughness, and chemical inertness, although it is not currently used in any biomedical applications. The purpose of this study is to serve as a preliminary investigation into the potential of PPP as a biomaterial in orthopedic load‐bearing applications. Nuclear magnetic resonance (NMR) analysis confirmed a polymer structure composed of an aromatic backbone and side groups. Tensile PPP specimens along with samples from several other polymers often used for orthopedic applications were elongated to failure after being soaked in phosphate buffered saline (PBS) for 1 h, 1 day, 1 week, 2 weeks, 1 month, and more than 1 year. Results showed that PBS absorption of the PPP plateaued at 1 week at values of ∼0.7 wt % and remained within one standard deviation when soaked for over 1 year. PBS absorption did not affect elastic modulus (5.0 GPa), yield strength (141 MPa), fracture strength (120 MPa) and strain‐to‐failure (17%) more than one standard deviation. Zero‐to‐tension fatigue testing established an endurance limit of approximately 35 MPa, which was relatively insensitive to frequency (1–10 Hz). Eagle's minimum essential medium (MEM) elution assay with fibroblasts confirmed that the PPP was noncytotoxic. Relative to other polymers used for load‐bearing biomedical applications, PPP displays promising mechanical properties that<abstract abstract-type="main"> <title>Abstract</title> <p>Poly(<italic>para</italic>‐phenylene) (PPP) exhibits exceptional mechanical strength, stiffness, toughness, and chemical inertness, although it is not currently used in any biomedical applications. The purpose of this study is to serve as a preliminary investigation into the potential of PPP as a biomaterial in orthopedic load‐bearing applications. Nuclear magnetic resonance (NMR) analysis confirmed a polymer structure composed of an aromatic backbone and side groups. Tensile PPP specimens along with samples from several other polymers often used for orthopedic applications were elongated to failure after being soaked in phosphate buffered saline (PBS) for 1 h, 1 day, 1 week, 2 weeks, 1 month, and more than 1 year. Results showed that PBS absorption of the PPP plateaued at 1 week at values of ∼0.7 wt % and remained within one standard deviation when soaked for over 1 year. PBS absorption did not affect elastic modulus (5.0 GPa), yield strength (141 MPa), fracture strength (120 MPa) and strain‐to‐failure (17%) more than one standard deviation. Zero‐to‐tension fatigue testing established an endurance limit of approximately 35 MPa, which was relatively insensitive to frequency (1–10 Hz). Eagle's minimum essential medium (MEM) elution assay with fibroblasts confirmed that the PPP was noncytotoxic. Relative to other polymers used for load‐bearing biomedical applications, PPP displays promising mechanical properties that remain stable in aqueous solution. Lastly, prototype PPP and polyetheretherketone (PEEK) bone plates were manufactured and tested, with the PPP plate showing a 38% higher maximum tensile load before failure. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A: 3122–3129, 2014.</p> </abstract> … (more)
- Is Part Of:
- Journal of biomedical materials research. Volume 102:Issue 9(2014)
- Journal:
- Journal of biomedical materials research
- Issue:
- Volume 102:Issue 9(2014)
- Issue Display:
- Volume 102, Issue 9 (2014)
- Year:
- 2014
- Volume:
- 102
- Issue:
- 9
- Issue Sort Value:
- 2014-0102-0009-0000
- Page Start:
- 3122
- Page End:
- 3129
- Publication Date:
- 2013-10-16
- Subjects:
- Biomedical materials -- Periodicals
610.28 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1552-4965 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jbm.a.34982 ↗
- Languages:
- English
- ISSNs:
- 1549-3296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.720000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3357.xml