Clinical Experience of Modified Diffusion‐Weighted Imaging Protocol for Lesion Detection in Transient Global Amnesia: An 8‐Year Large‐Scale Clinical Study. Issue 4 (2nd April 2013)
- Record Type:
- Journal Article
- Title:
- Clinical Experience of Modified Diffusion‐Weighted Imaging Protocol for Lesion Detection in Transient Global Amnesia: An 8‐Year Large‐Scale Clinical Study. Issue 4 (2nd April 2013)
- Main Title:
- Clinical Experience of Modified Diffusion‐Weighted Imaging Protocol for Lesion Detection in Transient Global Amnesia: An 8‐Year Large‐Scale Clinical Study
- Authors:
- Kim, Jungeun
Kwon, Yooseok
Yang, Youngsoon
Jang, Il Mi
Chang, YoungHee
Park, Young Ho
Jang, Jae Won
Kim, Jae Hyoung
Kim, SangYun - Abstract:
- <abstract abstract-type="main"> <title>ABSTRACT</title> <sec id="jon12021-sec-0010" sec-type="section"> <title>BACKGROUND AND PURPOSE</title> <p>The detection rate of typical transient global amnesia (TGA) lesions on diffusion‐weighted imaging (DWI) can be improved, up to 85% with optimal DWI parameters and imaging time. There is limited evidence that these findings are similar to those observed in large‐scale consecutive patients with TGA in clinical practice.</p> </sec> <sec id="jon12021-sec-0020" sec-type="section"> <title>METHODS</title> <p>Patients with clinically diagnosed TGA underwent magnetic resonance imaging studies, consecutively, with three sets of DWI parameters (standard clinical DWI protocols, the TGA DWI protocol I and the TGA DWI protocol II) in which the resolution, slice thickness, and the time interval between symptom onset of DWI were varied over an 8‐year period.</p> </sec> <sec id="jon12021-sec-0030" sec-type="section"> <title>RESULTS</title> <p>TGA lesion detection rates were up to 88% with a modified TGA DWI protocol. The lesion detection rate was the highest using TGA DWI protocol I, with <italic>b</italic> = 3, 000 s/mm<sup>2</sup>, a slice thickness of 3 mm, and performed on the third day after symptom onset, and TGA DWI protocol II, with <italic>b</italic> = 2, 000 s/mm<sup>2</sup> and a slice thickness of 2 mm.</p> </sec> <sec id="jon12021-sec-0040" sec-type="section"> <title>CONCLUSIONS</title> <p>A modified TGA DWI protocols for detecting TGA<abstract abstract-type="main"> <title>ABSTRACT</title> <sec id="jon12021-sec-0010" sec-type="section"> <title>BACKGROUND AND PURPOSE</title> <p>The detection rate of typical transient global amnesia (TGA) lesions on diffusion‐weighted imaging (DWI) can be improved, up to 85% with optimal DWI parameters and imaging time. There is limited evidence that these findings are similar to those observed in large‐scale consecutive patients with TGA in clinical practice.</p> </sec> <sec id="jon12021-sec-0020" sec-type="section"> <title>METHODS</title> <p>Patients with clinically diagnosed TGA underwent magnetic resonance imaging studies, consecutively, with three sets of DWI parameters (standard clinical DWI protocols, the TGA DWI protocol I and the TGA DWI protocol II) in which the resolution, slice thickness, and the time interval between symptom onset of DWI were varied over an 8‐year period.</p> </sec> <sec id="jon12021-sec-0030" sec-type="section"> <title>RESULTS</title> <p>TGA lesion detection rates were up to 88% with a modified TGA DWI protocol. The lesion detection rate was the highest using TGA DWI protocol I, with <italic>b</italic> = 3, 000 s/mm<sup>2</sup>, a slice thickness of 3 mm, and performed on the third day after symptom onset, and TGA DWI protocol II, with <italic>b</italic> = 2, 000 s/mm<sup>2</sup> and a slice thickness of 2 mm.</p> </sec> <sec id="jon12021-sec-0040" sec-type="section"> <title>CONCLUSIONS</title> <p>A modified TGA DWI protocols for detecting TGA lesions are useful in large‐scale clinical practice for confirming the diagnosis of TGA patients with clinical findings.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of neuroimaging. Volume 24:Issue 4(2014)
- Journal:
- Journal of neuroimaging
- Issue:
- Volume 24:Issue 4(2014)
- Issue Display:
- Volume 24, Issue 4 (2014)
- Year:
- 2014
- Volume:
- 24
- Issue:
- 4
- Issue Sort Value:
- 2014-0024-0004-0000
- Page Start:
- 331
- Page End:
- 337
- Publication Date:
- 2013-04-02
- Subjects:
- Diagnostic imaging -- Periodicals
Nervous system -- Diseases -- Diagnosis -- Periodicals
Imagerie pour le diagnostic -- Périodiques
Système nerveux -- Maladies -- Diagnostic -- Périodiques
Imagerie médicale
Neuroimagerie
Neurologie
Système nerveux
Périodique électronique (Descripteur de forme)
Ressource Internet (Descripteur de forme)
616.804754 - Journal URLs:
- http://jon.sagepub.com/ ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1552-6569 ↗
http://www.ingentaconnect.com/content/bpl/jon ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jon.12021 ↗
- Languages:
- English
- ISSNs:
- 1051-2284
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5021.548000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3800.xml