Compatibility of Electroanatomical Mapping Systems with a Concurrent Percutaneous Axial Flow Ventricular Assist Device. (3rd June 2014)
- Record Type:
- Journal Article
- Title:
- Compatibility of Electroanatomical Mapping Systems with a Concurrent Percutaneous Axial Flow Ventricular Assist Device. (3rd June 2014)
- Main Title:
- Compatibility of Electroanatomical Mapping Systems with a Concurrent Percutaneous Axial Flow Ventricular Assist Device
- Authors:
- VAIDYA, VAIBHAV R.
DESIMONE, CHRISTOPHER V.
MADHAVAN, MALINI
NOHERIA, AMIT
SHAHID, MOHAMMED
WALTERS, JACOB
LADEWIG, DOROTHY J.
MIKELL, SUSAN B.
JOHNSON, SUSAN B.
SUDDENDORF, SCOTT H.
ASIRVATHAM, SAMUEL J. - Abstract:
- <abstract abstract-type="main"> <title>Electromagnetic Interference with Ventricular Assist Device</title> <sec id="jce12437-sec-0010" sec-type="section"> <title>Background</title> <p>Hemodynamic instability hinders activation and entrainment mapping during ventricular tachycardia ablation. The Impella 2.5 microaxial flow device (MFD; Abiomed Inc., Danvers, MA, USA) is used to prevent hemodynamic instability during electrophysiologic study. However, electromagnetic interference (EMI) generated by this device can preclude accurate electroanatomic mapping.</p> </sec> <sec id="jce12437-sec-0020" sec-type="section"> <title>Methods</title> <p>Impella was placed in the left ventricle of 7 canines for circulatory support. Electroanatomic mapping during sinus rhythm, ventricular pacing, and ventricular fibrillation (VF) was performed using magnet‐ (CARTO3, Biosense Webster Inc., Diamond Bar, CA, USA) and impedance‐ (EnSite Velocity System/EnSite NavX, St. Jude Medical Inc., St. Paul, MN, USA) based systems. Distance from device to points with severe EMI precluding acquisition was compared to points with mild/no EMI. Two methods were used to reduce EMI: (1) titration of MFD performance, and (2) impedance‐only mapping combined with manual annotation of activation.</p> </sec> <sec id="jce12437-sec-0030" sec-type="section"> <title>Results</title> <p>Severe EMI did not occur during impedance‐based mapping. Severe EMI was observed using CARTO3 at 9.4% of all points attempted at maximum<abstract abstract-type="main"> <title>Electromagnetic Interference with Ventricular Assist Device</title> <sec id="jce12437-sec-0010" sec-type="section"> <title>Background</title> <p>Hemodynamic instability hinders activation and entrainment mapping during ventricular tachycardia ablation. The Impella 2.5 microaxial flow device (MFD; Abiomed Inc., Danvers, MA, USA) is used to prevent hemodynamic instability during electrophysiologic study. However, electromagnetic interference (EMI) generated by this device can preclude accurate electroanatomic mapping.</p> </sec> <sec id="jce12437-sec-0020" sec-type="section"> <title>Methods</title> <p>Impella was placed in the left ventricle of 7 canines for circulatory support. Electroanatomic mapping during sinus rhythm, ventricular pacing, and ventricular fibrillation (VF) was performed using magnet‐ (CARTO3, Biosense Webster Inc., Diamond Bar, CA, USA) and impedance‐ (EnSite Velocity System/EnSite NavX, St. Jude Medical Inc., St. Paul, MN, USA) based systems. Distance from device to points with severe EMI precluding acquisition was compared to points with mild/no EMI. Two methods were used to reduce EMI: (1) titration of MFD performance, and (2) impedance‐only mapping combined with manual annotation of activation.</p> </sec> <sec id="jce12437-sec-0030" sec-type="section"> <title>Results</title> <p>Severe EMI did not occur during impedance‐based mapping. Severe EMI was observed using CARTO3 at 9.4% of all points attempted at maximum performance level (P8) of device. Severe EMI occurred at points closer to device (40.1 ± 16.8 mm) versus (55.5 ± 20.0 mm) for mild/no EMI, P &lt; 0.0001. Severe EMI using CARTO3 was resolved by either (1) reduction of performance from P8 to P6 or (2) impedance‐only mapping with manual annotation.</p> </sec> <sec id="jce12437-sec-0040" sec-type="section"> <title>Conclusion</title> <p>Concurrent use of MFD caused EMI to prevent acquisition of points with magnet‐based mapping. Predictors for EMI were distance from device and performance level. Temporary reductions to P6 or impedance‐only mapping are 2 methods to resolve EMI.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 25:Number 7(2014:Jul.)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 25:Number 7(2014:Jul.)
- Issue Display:
- Volume 25, Issue 7 (2014)
- Year:
- 2014
- Volume:
- 25
- Issue:
- 7
- Issue Sort Value:
- 2014-0025-0007-0000
- Page Start:
- 781
- Page End:
- 786
- Publication Date:
- 2014-06-03
- Subjects:
- Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.12437 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4306.xml