Poly(glycidyl methacrylate‐co‐N‐methylolacrylamide‐co‐ethylene dimethacrylate) monolith coupled to high‐performance liquid chromatography for the determination of adenosine phosphates in royal jelly. Issue 14 (19th May 2014)
- Record Type:
- Journal Article
- Title:
- Poly(glycidyl methacrylate‐co‐N‐methylolacrylamide‐co‐ethylene dimethacrylate) monolith coupled to high‐performance liquid chromatography for the determination of adenosine phosphates in royal jelly. Issue 14 (19th May 2014)
- Main Title:
- Poly(glycidyl methacrylate‐co‐N‐methylolacrylamide‐co‐ethylene dimethacrylate) monolith coupled to high‐performance liquid chromatography for the determination of adenosine phosphates in royal jelly
- Authors:
- Liu, Dan
Zhang, Tianbin
Cheng, Yechun
Jia, Qiong - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>A polymer monolith microextraction method coupled with high‐performance liquid chromatography was developed for the determination of adenosine triphosphate, adenosine diphosphate, and adenosine monophosphate. The monolithic column was synthesized inside fused‐silica capillaries using thermal initiation free‐radical polymerization with glycidyl methacrylate as the monomer, ethylene dimethacrylate as the cross‐linker, cyclohexanol, and 1‐dodecanol as the porogen. <italic>N</italic>‐Methylolacrylamide, an important hydrophilic monomer, was incorporated into the polymerization mixture to enhance the hydrophilicity of the poly(glycidyl methacrylate‐<italic>co</italic>‐ethylene dimethacrylate) column. The obtained poly(glycidyl methacrylate‐<italic>co</italic>‐<italic>N</italic>‐methylolacrylamide‐<italic>co</italic>‐ethylene dimethacrylate) monolith was characterized by scanning electron microscopy, Fourier‐transform infrared spectra, and X‐ray photoelectron spectroscopy. Optimum conditions for the preconcentration and separation of the target adenosines were also investigated. Under the optimum conditions, we obtained acceptable linearities, low limits of detection, and good relative standard deviations. The developed polymer monolith microextraction with high‐performance liquid chromatography method exhibited a good performance with recovery values in the range of 76.9−104.7% when applied<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>A polymer monolith microextraction method coupled with high‐performance liquid chromatography was developed for the determination of adenosine triphosphate, adenosine diphosphate, and adenosine monophosphate. The monolithic column was synthesized inside fused‐silica capillaries using thermal initiation free‐radical polymerization with glycidyl methacrylate as the monomer, ethylene dimethacrylate as the cross‐linker, cyclohexanol, and 1‐dodecanol as the porogen. <italic>N</italic>‐Methylolacrylamide, an important hydrophilic monomer, was incorporated into the polymerization mixture to enhance the hydrophilicity of the poly(glycidyl methacrylate‐<italic>co</italic>‐ethylene dimethacrylate) column. The obtained poly(glycidyl methacrylate‐<italic>co</italic>‐<italic>N</italic>‐methylolacrylamide‐<italic>co</italic>‐ethylene dimethacrylate) monolith was characterized by scanning electron microscopy, Fourier‐transform infrared spectra, and X‐ray photoelectron spectroscopy. Optimum conditions for the preconcentration and separation of the target adenosines were also investigated. Under the optimum conditions, we obtained acceptable linearities, low limits of detection, and good relative standard deviations. The developed polymer monolith microextraction with high‐performance liquid chromatography method exhibited a good performance with recovery values in the range of 76.9−104.7% when applied to the determination of the adenosines in five royal jelly samples.</p> </abstract> … (more)
- Is Part Of:
- Journal of separation science. Volume 37:Issue 14(2014:Jul.)
- Journal:
- Journal of separation science
- Issue:
- Volume 37:Issue 14(2014:Jul.)
- Issue Display:
- Volume 37, Issue 14 (2014)
- Year:
- 2014
- Volume:
- 37
- Issue:
- 14
- Issue Sort Value:
- 2014-0037-0014-0000
- Page Start:
- 1826
- Page End:
- 1833
- Publication Date:
- 2014-05-19
- Subjects:
- Separation (Technology) -- Periodicals
Chromatographic analysis -- Periodicals
543.089 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1615-9314 ↗
http://www.interscience.wiley.com/jpages/1615-9306 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jssc.201400187 ↗
- Languages:
- English
- ISSNs:
- 1615-9306
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5063.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4070.xml