Diagnostic accuracy of dynamic gadoxetic‐acid–enhanced MRI and PET/CT compared in patients with liver metastases from neuroendocrine neoplasms. Issue 2 (18th December 2013)
- Record Type:
- Journal Article
- Title:
- Diagnostic accuracy of dynamic gadoxetic‐acid–enhanced MRI and PET/CT compared in patients with liver metastases from neuroendocrine neoplasms. Issue 2 (18th December 2013)
- Main Title:
- Diagnostic accuracy of dynamic gadoxetic‐acid–enhanced MRI and PET/CT compared in patients with liver metastases from neuroendocrine neoplasms
- Authors:
- Armbruster, Marco
Zech, Christoph J.
Sourbron, Steven
Ceelen, Felix
Auernhammer, Christoph J.
Rist, Carsten
Haug, Alexander
Singnurkar, Amit
Reiser, Maximilian F.
Sommer, Wieland H. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24363-sec-0001" sec-type="section"> <title>Purpose</title> <p>To evaluate the diagnostic accuracy of dynamic‐contrast–enhanced (DCE) MRI in comparison to both <sup>18</sup>F‐FDG‐ and <sup>68</sup>Ga‐DOTATATE‐PET/CT in patients with liver metastases of neuroendocrine neoplasms (NEN).</p> </sec> <sec id="jmri24363-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Thirty‐two patients with hepatic metastases from NEN were examined both in DCE‐MRI and positron emission tomography/computed tomography (PET/CT), using either <sup>18</sup>F‐fluorodeoxyglucose (<sup>18</sup>F‐FDG) or <sup>68</sup>Ga‐DOTATATE as tracer. DCE‐MRI was performed at 3 Tesla with Gd‐EOB‐DTPA acquiring 48 slices every 2.2 s for 5 min. Three regions of interest (ROIs) representing liver background and liver metastases were defined in fat‐saturated T1w three‐dimensional GRE MRI sequences in the hepatobiliary phase. Corresponding ROIs were then defined in the DCE‐MRI‐ and in the PET/CT‐dataset. Area under the curve (AUC) was calculated for the differentiation between metastases and liver background for DCE‐MRI and PET‐CT parameters.</p> </sec> <sec id="jmri24363-sec-0003" sec-type="section"> <title>Results</title> <p>AUC was very high for SUV<sub>mean</sub> (mean standardized uptake value) derived from <sup>68</sup>Ga‐DOTATATE‐ (AUC = 0.966), and <sup>18</sup>F‐FDG‐PET/CT (AUC = 0.989). For<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24363-sec-0001" sec-type="section"> <title>Purpose</title> <p>To evaluate the diagnostic accuracy of dynamic‐contrast–enhanced (DCE) MRI in comparison to both <sup>18</sup>F‐FDG‐ and <sup>68</sup>Ga‐DOTATATE‐PET/CT in patients with liver metastases of neuroendocrine neoplasms (NEN).</p> </sec> <sec id="jmri24363-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Thirty‐two patients with hepatic metastases from NEN were examined both in DCE‐MRI and positron emission tomography/computed tomography (PET/CT), using either <sup>18</sup>F‐fluorodeoxyglucose (<sup>18</sup>F‐FDG) or <sup>68</sup>Ga‐DOTATATE as tracer. DCE‐MRI was performed at 3 Tesla with Gd‐EOB‐DTPA acquiring 48 slices every 2.2 s for 5 min. Three regions of interest (ROIs) representing liver background and liver metastases were defined in fat‐saturated T1w three‐dimensional GRE MRI sequences in the hepatobiliary phase. Corresponding ROIs were then defined in the DCE‐MRI‐ and in the PET/CT‐dataset. Area under the curve (AUC) was calculated for the differentiation between metastases and liver background for DCE‐MRI and PET‐CT parameters.</p> </sec> <sec id="jmri24363-sec-0003" sec-type="section"> <title>Results</title> <p>AUC was very high for SUV<sub>mean</sub> (mean standardized uptake value) derived from <sup>68</sup>Ga‐DOTATATE‐ (AUC = 0.966), and <sup>18</sup>F‐FDG‐PET/CT (AUC = 0.989). For DCE‐MRI parameters, arterial flow fraction and intracellular uptake fraction showed the highest AUCs (AUC = 0.826, AUC = 0.819, respectively). The combination of those two had an AUC of 0.949. The combination of DCE‐MRI and PET‐CT parameters resulted in the highest AUC.</p> </sec> <sec id="jmri24363-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Both PET/CT parameters and DCE‐MRI perfusion parameters show a high diagnostic accuracy in the distinction between liver metastases and liver tissue. Our data suggest that both modalities provide complementary information. <bold>J. Magn. Reson. Imaging 2014;40:457–466</bold>. © <bold>2013 Wiley Periodicals, Inc</bold>.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 40:Issue 2(2014)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 40:Issue 2(2014)
- Issue Display:
- Volume 40, Issue 2 (2014)
- Year:
- 2014
- Volume:
- 40
- Issue:
- 2
- Issue Sort Value:
- 2014-0040-0002-0000
- Page Start:
- 457
- Page End:
- 466
- Publication Date:
- 2013-12-18
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.24363 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3598.xml