Validation of the only commercially available immunoassay for synthetic cathinones in urine: Randox Drugs of Abuse V Biochip Array Technology. Issue 7 (21st March 2014)
- Record Type:
- Journal Article
- Title:
- Validation of the only commercially available immunoassay for synthetic cathinones in urine: Randox Drugs of Abuse V Biochip Array Technology. Issue 7 (21st March 2014)
- Main Title:
- Validation of the only commercially available immunoassay for synthetic cathinones in urine: Randox Drugs of Abuse V Biochip Array Technology
- Authors:
- Ellefsen, Kayla N.
Anizan, Sébastien
Castaneto, Marisol S.
Desrosiers, Nathalie A.
Martin, Thomas M.
Klette, Kevin L.
Huestis, Marilyn A.
Brandt, Simon D. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>Deterrence of synthetic cathinone abuse is hampered by the lack of a high‐throughput immunoassay screen. The Randox Drugs of Abuse V (DOA‐V) Biochip Array Technology contains two synthetic cathinone antibodies: Bath Salt I (BSI) targets mephedrone/methcathinone and Bath Salt II (BSII) targets 3', 4'‐methylenedioxypyrovalerone (MDPV)/3', 4'‐methylenedioxy‐α‐pyrrolidinobutiophenone (MDPBP). We evaluated DOA‐V synthetic cathinones performance and conducted a full validation on the original assay with calibrators reconstituted in water, and the new assay with calibrators prepared in lyophilized urine; both utilized the same antibodies and were run on the fully automated Evidence® Analyzer. We screened 20 017 authentic military urine specimens and confirmed positives by liquid chromatography‐tandem mass spectrometry (LC‐MS/MS) for 28 synthetic cathinones. Limits of detection (LOD) for the original and new assays were 0.35 and 0.18 (BSI), and 8.5 and 9.2 µg/L (BSII), respectively. Linearity was acceptable (R<sup>2</sup> &gt; 0.98); however, a large negative bias was observed with in‐house prepared calibrators. Intra‐assay imprecision was &lt;20% BSI‐II, while inter‐assay imprecision was 18‐42% BSI and &lt;22% BSII. Precision was acceptable for Randox controls. Cross‐reactivities of many additional synthetic cathinones were determined. Authentic drug‐free negative urine pH &lt;4 produced false<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>Deterrence of synthetic cathinone abuse is hampered by the lack of a high‐throughput immunoassay screen. The Randox Drugs of Abuse V (DOA‐V) Biochip Array Technology contains two synthetic cathinone antibodies: Bath Salt I (BSI) targets mephedrone/methcathinone and Bath Salt II (BSII) targets 3', 4'‐methylenedioxypyrovalerone (MDPV)/3', 4'‐methylenedioxy‐α‐pyrrolidinobutiophenone (MDPBP). We evaluated DOA‐V synthetic cathinones performance and conducted a full validation on the original assay with calibrators reconstituted in water, and the new assay with calibrators prepared in lyophilized urine; both utilized the same antibodies and were run on the fully automated Evidence® Analyzer. We screened 20 017 authentic military urine specimens and confirmed positives by liquid chromatography‐tandem mass spectrometry (LC‐MS/MS) for 28 synthetic cathinones. Limits of detection (LOD) for the original and new assays were 0.35 and 0.18 (BSI), and 8.5 and 9.2 µg/L (BSII), respectively. Linearity was acceptable (R<sup>2</sup> &gt; 0.98); however, a large negative bias was observed with in‐house prepared calibrators. Intra‐assay imprecision was &lt;20% BSI‐II, while inter‐assay imprecision was 18‐42% BSI and &lt;22% BSII. Precision was acceptable for Randox controls. Cross‐reactivities of many additional synthetic cathinones were determined. Authentic drug‐free negative urine pH &lt;4 produced false positive results for BSI (6.3 µg/L) and BSII (473 µg/L). Oxidizing agents reduced BSI and increased BSII results. Sensitivity, specificity, and efficiency of 100%, 52.1%, and 53.0% were obtained at manufacturer's proposed cut‐offs (BSI 5 µg/L, BSII 30 µg/L). Performance improved if cut‐off concentrations increased (BSI 7.5 µg/L, BSII 40 µg/L); however, there were limited confirmed positive specimens. Currently, this is the first and only fully validated immunoassay for preliminary detection of synthetic cathinones in urine. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.</p> </abstract> … (more)
- Is Part Of:
- Drug testing and analysis. Volume 6:Issue 7/8(2014)
- Journal:
- Drug testing and analysis
- Issue:
- Volume 6:Issue 7/8(2014)
- Issue Display:
- Volume 6, Issue 7/8 (2014)
- Year:
- 2014
- Volume:
- 6
- Issue:
- 7/8
- Issue Sort Value:
- 2014-0006-NaN-0000
- Page Start:
- 728
- Page End:
- 738
- Publication Date:
- 2014-03-21
- Subjects:
- Drugs -- Analysis -- Periodicals
Drug testing -- Periodicals
Chemistry, Forensic -- Periodicals
615.1901 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1942-7611 ↗
http://rzblx1.uni-regensburg.de/ezeit/warpto.phtml?colors=7&jour_id=110501 ↗
http://www3.interscience.wiley.com/journal/121408477/home ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/dta.1633 ↗
- Languages:
- English
- ISSNs:
- 1942-7603
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3629.424000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4149.xml