Home interventions are effective at decreasing indoor nitrogen dioxide concentrations. (11th January 2014)
- Record Type:
- Journal Article
- Title:
- Home interventions are effective at decreasing indoor nitrogen dioxide concentrations. (11th January 2014)
- Main Title:
- Home interventions are effective at decreasing indoor nitrogen dioxide concentrations
- Authors:
- Paulin, L. M.
Diette, G. B.
Scott, M.
McCormack, M. C.
Matsui, E. C.
Curtin‐Brosnan, J.
Williams, D. L.
Kidd‐Taylor, A.
Shea, M.
Breysse, P. N.
Hansel, N. N. - Abstract:
- <abstract abstract-type="main" id="ina12085-abs-0001"> <title>Abstract</title> <p>Nitrogen dioxide (NO<sub>2</sub>), a by‐product of combustion produced by indoor gas appliances such as cooking stoves, is associated with respiratory symptoms in those with obstructive airways disease. We conducted a three‐armed randomized trial to evaluate the efficacy of interventions aimed at reducing indoor NO<sub>2</sub> concentrations in homes with unvented gas stoves: (i) replacement of existing gas stove with electric stove; (ii) installation of ventilation hood over existing gas stove; and (iii) placement of air purifiers with high‐efficiency particulate air (HEPA) and carbon filters. Home inspection and NO<sub>2</sub> monitoring were conducted at 1 week pre‐intervention and at 1 week and 3 months post‐intervention. Stove replacement resulted in a 51% and 42% decrease in median NO<sub>2</sub> concentration at 3 months of follow‐up in the kitchen and bedroom, respectively (<italic>P</italic> = 0.01, <italic>P</italic> = 0.01); air purifier placement resulted in an immediate decrease in median NO<sub>2</sub> concentration in the kitchen (27%, <italic>P</italic> &lt; 0.01) and bedroom (22%, <italic>P</italic> = 0.02), but at 3 months, a significant reduction was seen only in the kitchen (20%, <italic>P</italic> = 0.05). NO<sub>2</sub> concentrations in the kitchen and bedroom did not significantly change following ventilation hood installation. Replacing unvented gas stoves with electric<abstract abstract-type="main" id="ina12085-abs-0001"> <title>Abstract</title> <p>Nitrogen dioxide (NO<sub>2</sub>), a by‐product of combustion produced by indoor gas appliances such as cooking stoves, is associated with respiratory symptoms in those with obstructive airways disease. We conducted a three‐armed randomized trial to evaluate the efficacy of interventions aimed at reducing indoor NO<sub>2</sub> concentrations in homes with unvented gas stoves: (i) replacement of existing gas stove with electric stove; (ii) installation of ventilation hood over existing gas stove; and (iii) placement of air purifiers with high‐efficiency particulate air (HEPA) and carbon filters. Home inspection and NO<sub>2</sub> monitoring were conducted at 1 week pre‐intervention and at 1 week and 3 months post‐intervention. Stove replacement resulted in a 51% and 42% decrease in median NO<sub>2</sub> concentration at 3 months of follow‐up in the kitchen and bedroom, respectively (<italic>P</italic> = 0.01, <italic>P</italic> = 0.01); air purifier placement resulted in an immediate decrease in median NO<sub>2</sub> concentration in the kitchen (27%, <italic>P</italic> &lt; 0.01) and bedroom (22%, <italic>P</italic> = 0.02), but at 3 months, a significant reduction was seen only in the kitchen (20%, <italic>P</italic> = 0.05). NO<sub>2</sub> concentrations in the kitchen and bedroom did not significantly change following ventilation hood installation. Replacing unvented gas stoves with electric stoves or placement of air purifiers with HEPA and carbon filters can decrease indoor NO<sub>2</sub> concentrations in urban homes.</p> </abstract> … (more)
- Is Part Of:
- Indoor air. Volume 24:Number 4(2014:Aug.)
- Journal:
- Indoor air
- Issue:
- Volume 24:Number 4(2014:Aug.)
- Issue Display:
- Volume 24, Issue 4 (2014)
- Year:
- 2014
- Volume:
- 24
- Issue:
- 4
- Issue Sort Value:
- 2014-0024-0004-0000
- Page Start:
- 416
- Page End:
- 424
- Publication Date:
- 2014-01-11
- Subjects:
- Indoor air pollution -- Periodicals
Sick building syndrome -- Periodicals
Ventilation -- Periodicals
613.5 - Journal URLs:
- http://www.blackwell-synergy.com/loi/ina ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1600-0668 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ina.12085 ↗
- Languages:
- English
- ISSNs:
- 0905-6947
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4438.046530
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3028.xml