A New Eu3+‐Labeled Method for Anticardiolipin Antibody IgM. Issue 4 (22nd March 2014)
- Record Type:
- Journal Article
- Title:
- A New Eu3+‐Labeled Method for Anticardiolipin Antibody IgM. Issue 4 (22nd March 2014)
- Main Title:
- A New Eu3+‐Labeled Method for Anticardiolipin Antibody IgM
- Authors:
- Ye, Yan
Hu, Zhigang
Liu, Jie
Chen, Guoqian
Zhou, Yaohong - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jcla21690-sec-0010" sec-type="section"> <title>Background</title> <p>The anticardiolipin antibodies (aCL) test has become a laboratory standard for the clinical diagnosis of antiphospholipid syndrome (APS). To better the quantitative detection of aCL‐IgM so as to classify patients correctly and timely as APS positive, we established herein a new immunoassay based on a time‐resolved fluoroimmunoassay (TRFIA).</p> </sec> <sec id="jcla21690-sec-0020" sec-type="section"> <title>Methods</title> <p>The complex of cardiolipin plus bovine anti‐β<sub>2</sub> glycoprotein‐I was used as antigen fixed on microtiter plates to detect serum aCL‐IgM, and Eu<sup>3+</sup>‐labeled rabbit antihuman IgM was used as conjugate. The precision, sensitivity, specificity, coefficient of recovery, and stability of the assay were evaluated, and comparison with the traditional, classical enzyme‐linked immunosorbent assay (ELISA) was also made.</p> </sec> <sec id="jcla21690-sec-0030" sec-type="section"> <title>Results</title> <p>The detection limit of the aCL‐IgM TRFIA kit we established was 0.1 MPL U/ml, with a wider detectable range than commercial ELISA ones when a strong‐positive specimen was diluted from 2, 630.9 to 0.08 MPL U/ml. There was a good liner range within 0.16 to 2, 630.9 MPL U/ml, whereas it was within 5.14 to 328.86 MPL U/ml when using three commercial ELISA ones. The average intra‐ and<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jcla21690-sec-0010" sec-type="section"> <title>Background</title> <p>The anticardiolipin antibodies (aCL) test has become a laboratory standard for the clinical diagnosis of antiphospholipid syndrome (APS). To better the quantitative detection of aCL‐IgM so as to classify patients correctly and timely as APS positive, we established herein a new immunoassay based on a time‐resolved fluoroimmunoassay (TRFIA).</p> </sec> <sec id="jcla21690-sec-0020" sec-type="section"> <title>Methods</title> <p>The complex of cardiolipin plus bovine anti‐β<sub>2</sub> glycoprotein‐I was used as antigen fixed on microtiter plates to detect serum aCL‐IgM, and Eu<sup>3+</sup>‐labeled rabbit antihuman IgM was used as conjugate. The precision, sensitivity, specificity, coefficient of recovery, and stability of the assay were evaluated, and comparison with the traditional, classical enzyme‐linked immunosorbent assay (ELISA) was also made.</p> </sec> <sec id="jcla21690-sec-0030" sec-type="section"> <title>Results</title> <p>The detection limit of the aCL‐IgM TRFIA kit we established was 0.1 MPL U/ml, with a wider detectable range than commercial ELISA ones when a strong‐positive specimen was diluted from 2, 630.9 to 0.08 MPL U/ml. There was a good liner range within 0.16 to 2, 630.9 MPL U/ml, whereas it was within 5.14 to 328.86 MPL U/ml when using three commercial ELISA ones. The average intra‐ and interassay variability was 3.19 and 3.70%, respectively. The mean recovery rate was 101.95%. The clinical diagnostic specificity was 98%. Additionally, the established assay kit presented good characteristics of stability and correlated well with the ELISA, and the correlation coefficient was 0.955.</p> </sec> <sec id="jcla21690-sec-0040" sec-type="section"> <title>Conclusion</title> <p>The aCL‐IgM TRFIA provides an approach to a more sensitive and reliable diagnosis of APS. Further validation of its use is required.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 28:Issue 4(2014:Jul.)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 28:Issue 4(2014:Jul.)
- Issue Display:
- Volume 28, Issue 4 (2014)
- Year:
- 2014
- Volume:
- 28
- Issue:
- 4
- Issue Sort Value:
- 2014-0028-0004-0000
- Page Start:
- 335
- Page End:
- 340
- Publication Date:
- 2014-03-22
- Subjects:
- Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.21690 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4078.xml