Assessment of in vivo laser ablation using MR elastography with an inertial driver. Issue 1 (31st July 2013)
- Record Type:
- Journal Article
- Title:
- Assessment of in vivo laser ablation using MR elastography with an inertial driver. Issue 1 (31st July 2013)
- Main Title:
- Assessment of in vivo laser ablation using MR elastography with an inertial driver
- Authors:
- Chen, Jun
Woodrum, David A.
Glaser, Kevin J.
Murphy, Matthew C.
Gorny, Krzysztof
Ehman, Richard - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="mrm24891-sec-0019" sec-type="section"> <title>Purpose</title> <p>To evaluate the feasibility of using MR Elastography (MRE) to monitor tissue coagulation extent during in vivo percutaneous laser ablation of the liver.</p> </sec> <sec id="mrm24891-sec-0020" sec-type="section"> <title>Methods</title> <p>A novel inertial acoustic driver was developed to apply mechanical waves via the ablation instrument. Ablation testing was performed in live juvenile female pigs under anesthesia in a 1.5‐T whole‐body MRI scanner.</p> </sec> <sec id="mrm24891-sec-0021" sec-type="section"> <title>Results</title> <p>The inertial driver produced suitable mechanical wave fields in the liver before, during, and after the laser ablation. During 2‐min ablations using 4.5‐, 7.5‐ and 15‐W laser power, the stiffness of the lesions changed substantially in response to laser heating, indicative of protein denaturation. After a lethal thermal dose (2‐min, 15‐W) ablation, lesion stiffness was significantly greater than the baseline values (<italic>P</italic> &lt; 0.007) and became stiffer over time; the mean stiffness increments from baseline were significantly greater than those after lower dose (2‐min, 7.5‐W) ablations (64.4% vs. 22.5%, <italic>P</italic> = 0.009).</p> </sec> <sec id="mrm24891-sec-0022" sec-type="section"> <title>Conclusion</title> <p>MRE was shown capable of measuring tissue stiffness changes<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="mrm24891-sec-0019" sec-type="section"> <title>Purpose</title> <p>To evaluate the feasibility of using MR Elastography (MRE) to monitor tissue coagulation extent during in vivo percutaneous laser ablation of the liver.</p> </sec> <sec id="mrm24891-sec-0020" sec-type="section"> <title>Methods</title> <p>A novel inertial acoustic driver was developed to apply mechanical waves via the ablation instrument. Ablation testing was performed in live juvenile female pigs under anesthesia in a 1.5‐T whole‐body MRI scanner.</p> </sec> <sec id="mrm24891-sec-0021" sec-type="section"> <title>Results</title> <p>The inertial driver produced suitable mechanical wave fields in the liver before, during, and after the laser ablation. During 2‐min ablations using 4.5‐, 7.5‐ and 15‐W laser power, the stiffness of the lesions changed substantially in response to laser heating, indicative of protein denaturation. After a lethal thermal dose (2‐min, 15‐W) ablation, lesion stiffness was significantly greater than the baseline values (<italic>P</italic> &lt; 0.007) and became stiffer over time; the mean stiffness increments from baseline were significantly greater than those after lower dose (2‐min, 7.5‐W) ablations (64.4% vs. 22.5%, <italic>P</italic> = 0.009).</p> </sec> <sec id="mrm24891-sec-0022" sec-type="section"> <title>Conclusion</title> <p>MRE was shown capable of measuring tissue stiffness changes due to in vivo laser ablation. If confirmed through additional studies, this technology may be useful in clinical tumor ablation to monitor the spatial extent of tissue coagulation. <bold>Magn Reson Med 72:59–67, 2014. © 2013 Wiley Periodicals, Inc.</bold></p> </sec> </abstract> … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 72:Issue 1(2014:Jul.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 72:Issue 1(2014:Jul.)
- Issue Display:
- Volume 72, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 72
- Issue:
- 1
- Issue Sort Value:
- 2014-0072-0001-0000
- Page Start:
- 59
- Page End:
- 67
- Publication Date:
- 2013-07-31
- Subjects:
- Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.24891 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4345.xml