Polyvinylimidazole/sol–gel composite as a novel solid‐phase microextraction coating for the determination of halogenated benzenes from aqueous solutions. Issue 12 (15th May 2014)
- Record Type:
- Journal Article
- Title:
- Polyvinylimidazole/sol–gel composite as a novel solid‐phase microextraction coating for the determination of halogenated benzenes from aqueous solutions. Issue 12 (15th May 2014)
- Main Title:
- Polyvinylimidazole/sol–gel composite as a novel solid‐phase microextraction coating for the determination of halogenated benzenes from aqueous solutions
- Authors:
- Farjaminezhad, Manoochehr
Tehrani, Mohammad Saber
Azar, Parviz Aberoomand
Hussain, Syed Waqif
Bohlooli, Shahab - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>A polyvinylimidazole/sol–gel composite is proposed as a novel solid‐phase microextraction fiber to extract five halobenzenes from the headspace of aqueous solutions in combination with gas chromatography with mass spectrometry. The prepared fiber was characterized by scanning electron microscopy and Fourier transform infrared spectroscopy. The obtained results showed that porous polyvinylimidazole/sol–gel composite was chemically deposited on fused silica fiber. The effect of important extraction parameters including extraction temperature, extraction time, and salt content were investigated. The optimum conditions were as follows: extraction temperature 25°C, extraction time 20 min, and salt concentration 30 w/v%. Detection limits and relative standard deviations of the developed method for halogenated benzenes were below 0.1 pg/mL and 15%, respectively. Repeatability of the proposed method, explained by relative standard deviation, varied between 5.48 and 9.15% (<italic>n</italic> = 5). The limits of detection (S/N = 3) ranged between 0.01 and 0.10 ng/L using gas chromatography with mass spectrometry with selected ion monitoring mode. For real sample analysis, three types of water samples with different matrices (ground, surface, and tap water) were studied. The optimized procedure was applied to extraction and method validation of halogenated benzenes in spiked water samples.</p><abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>A polyvinylimidazole/sol–gel composite is proposed as a novel solid‐phase microextraction fiber to extract five halobenzenes from the headspace of aqueous solutions in combination with gas chromatography with mass spectrometry. The prepared fiber was characterized by scanning electron microscopy and Fourier transform infrared spectroscopy. The obtained results showed that porous polyvinylimidazole/sol–gel composite was chemically deposited on fused silica fiber. The effect of important extraction parameters including extraction temperature, extraction time, and salt content were investigated. The optimum conditions were as follows: extraction temperature 25°C, extraction time 20 min, and salt concentration 30 w/v%. Detection limits and relative standard deviations of the developed method for halogenated benzenes were below 0.1 pg/mL and 15%, respectively. Repeatability of the proposed method, explained by relative standard deviation, varied between 5.48 and 9.15% (<italic>n</italic> = 5). The limits of detection (S/N = 3) ranged between 0.01 and 0.10 ng/L using gas chromatography with mass spectrometry with selected ion monitoring mode. For real sample analysis, three types of water samples with different matrices (ground, surface, and tap water) were studied. The optimized procedure was applied to extraction and method validation of halogenated benzenes in spiked water samples.</p> </abstract> … (more)
- Is Part Of:
- Journal of separation science. Volume 37:Issue 12(2014:Jun.)
- Journal:
- Journal of separation science
- Issue:
- Volume 37:Issue 12(2014:Jun.)
- Issue Display:
- Volume 37, Issue 12 (2014)
- Year:
- 2014
- Volume:
- 37
- Issue:
- 12
- Issue Sort Value:
- 2014-0037-0012-0000
- Page Start:
- 1475
- Page End:
- 1481
- Publication Date:
- 2014-05-15
- Subjects:
- Separation (Technology) -- Periodicals
Chromatographic analysis -- Periodicals
543.089 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1615-9314 ↗
http://www.interscience.wiley.com/jpages/1615-9306 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jssc.201301238 ↗
- Languages:
- English
- ISSNs:
- 1615-9306
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5063.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4158.xml