Cytotoxicity of coated and uncoated fibre-reinforced composites. (July 2013)
- Record Type:
- Journal Article
- Title:
- Cytotoxicity of coated and uncoated fibre-reinforced composites. (July 2013)
- Main Title:
- Cytotoxicity of coated and uncoated fibre-reinforced composites
- Authors:
- Frese, Cornelia
Wolff, Diana
Zingler, Sebastian
Krueger, Tanja
Stucke, Kathrin
Lux, Christopher J.
Staehle, Hans Joerg
Erber, Ralf - Abstract:
- <abstract> <title>Abstract</title> <p> <bold> <italic>Objective.</italic> </bold> Currently, there are many fibre-reinforced composites (FRCs) available which differ in the type and volume fraction of fibres, pre-treatment of fibres and matrix composition. The aims of this <italic>in vitro</italic> investigation were to determine whether there is a difference in biocompatibility of FRCs and if coating FRCs with resin composites influences their cytotoxic potential. <bold><italic>Materials and methods. </italic></bold>Five different FRC materials were tested which were either uncoated or coated with flowable or viscous resin composite. Artificial saliva extracts were prepared according to USP-XXIII and <italic>ISO</italic>-10993 to determine cytotoxicity by testing cell viability and growth of primary human gingival fibroblasts (HGF) using MTT assay, LIVE/DEAD® assay and cell proliferation assay. The influence of eluates on fibres of the cytoskeleton was investigated by vimentin, tubulin and actinin immunostainings. A two-way ANOVA followed by Scheffe's post-hoc test, which included the factors FRC material and coating procedure, was performed to assess cytotoxicity. <bold><italic>Results.</italic></bold> All extracts of FRC materials displayed minor cytotoxic potential on HGF cell viability, cell proliferation and integrity of the cytoskeleton. The type of FRC material significantly influenced cell viability (MTT assay) (<italic>p</italic> &lt; 0.0001), whereas neither the<abstract> <title>Abstract</title> <p> <bold> <italic>Objective.</italic> </bold> Currently, there are many fibre-reinforced composites (FRCs) available which differ in the type and volume fraction of fibres, pre-treatment of fibres and matrix composition. The aims of this <italic>in vitro</italic> investigation were to determine whether there is a difference in biocompatibility of FRCs and if coating FRCs with resin composites influences their cytotoxic potential. <bold><italic>Materials and methods. </italic></bold>Five different FRC materials were tested which were either uncoated or coated with flowable or viscous resin composite. Artificial saliva extracts were prepared according to USP-XXIII and <italic>ISO</italic>-10993 to determine cytotoxicity by testing cell viability and growth of primary human gingival fibroblasts (HGF) using MTT assay, LIVE/DEAD® assay and cell proliferation assay. The influence of eluates on fibres of the cytoskeleton was investigated by vimentin, tubulin and actinin immunostainings. A two-way ANOVA followed by Scheffe's post-hoc test, which included the factors FRC material and coating procedure, was performed to assess cytotoxicity. <bold><italic>Results.</italic></bold> All extracts of FRC materials displayed minor cytotoxic potential on HGF cell viability, cell proliferation and integrity of the cytoskeleton. The type of FRC material significantly influenced cell viability (MTT assay) (<italic>p</italic> &lt; 0.0001), whereas neither the presence of a coating nor the type of coating material resulted in altered cell viability. Distribution and organization of cytosolic fibres was not affected after HGF exposure to eluates. <bold><italic>Conclusions.</italic></bold> There is a lack of knowledge about the leaching behaviour of commonly available fully pre-impregnated FRCs and their interactions with coating materials. The coating of FRCs with resin composite materials did not impact biocompatibility.</p> </abstract> … (more)
- Is Part Of:
- Acta odontologica Scandinavica. Volume 72:Number 5(2014)
- Journal:
- Acta odontologica Scandinavica
- Issue:
- Volume 72:Number 5(2014)
- Issue Display:
- Volume 72, Issue 5 (2014)
- Year:
- 2014
- Volume:
- 72
- Issue:
- 5
- Issue Sort Value:
- 2014-0072-0005-0000
- Page Start:
- 321
- Page End:
- 330
- Publication Date:
- 2013-07
- Subjects:
- Dentistry -- Periodicals
617.6005 - Journal URLs:
- http://www.ingentaconnect.com/content/apl/sodo ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/00016357.2013.826381 ↗
- Languages:
- English
- ISSNs:
- 0001-6357
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0641.630000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3802.xml