A randomized clinical trial comparing guided implant surgery (bone‐ or mucosa‐supported) with mental navigation or the use of a pilot‐drill template. (10th April 2014)
- Record Type:
- Journal Article
- Title:
- A randomized clinical trial comparing guided implant surgery (bone‐ or mucosa‐supported) with mental navigation or the use of a pilot‐drill template. (10th April 2014)
- Main Title:
- A randomized clinical trial comparing guided implant surgery (bone‐ or mucosa‐supported) with mental navigation or the use of a pilot‐drill template
- Authors:
- Vercruyssen, Marjolein
Cox, Catherine
Coucke, Wim
Naert, Ignace
Jacobs, Reinhilde
Quirynen, Marc - Abstract:
- <abstract abstract-type="main" id="jcpe12231-abs-0001"> <title>Abstract</title> <sec id="jcpe12231-sec-0001" sec-type="section"> <title>Aim</title> <p>To assess the accuracy of guided surgery (mucosa and bone‐supported) compared to mental navigation or the use of a surgical template, in fully edentulous jaws, in a randomized controlled study.</p> </sec> <sec id="jcpe12231-sec-0002" sec-type="section"> <title>Material and Methods</title> <p>Fifty‐nine patients (72 jaws), requiring four to six implants (maxilla or mandible), were consecutively recruited and randomly assigned to one of the following treatment groups; guidance via Materialise Universal<sup>®</sup>/mucosa, Materialise Universal<sup>®</sup>/bone, Facilitate™/mucosa, Facilitate™/bone, or mental navigation or a pilot‐drill template. The precision was assessed by matching the planning computed tomography (CT) with a post‐operative cone beam CT.</p> </sec> <sec id="jcpe12231-sec-0003" sec-type="section"> <title>Results</title> <p>A significant lower mean deviation at the entry point (1.4 mm, range: 0.3–3.7), at the apex (1.6 mm, range: 0.2–3.7) and angular deviation (3.0°, range: 0.2–16°) was observed for the guiding systems when compared to mental navigation (2.7 mm, range: 0.3–8.3; 2.9 mm, range: 0.5–7.4 and 9.9°, range: 1.5–27.8) and to the surgical template group (3.0 mm, range: 0.6–6.6; 3.4 mm, range: 0.3–7.5 and 8.4°, range: 0.6–21.3°). Differences between bone and mucosa support or type of guidance were<abstract abstract-type="main" id="jcpe12231-abs-0001"> <title>Abstract</title> <sec id="jcpe12231-sec-0001" sec-type="section"> <title>Aim</title> <p>To assess the accuracy of guided surgery (mucosa and bone‐supported) compared to mental navigation or the use of a surgical template, in fully edentulous jaws, in a randomized controlled study.</p> </sec> <sec id="jcpe12231-sec-0002" sec-type="section"> <title>Material and Methods</title> <p>Fifty‐nine patients (72 jaws), requiring four to six implants (maxilla or mandible), were consecutively recruited and randomly assigned to one of the following treatment groups; guidance via Materialise Universal<sup>®</sup>/mucosa, Materialise Universal<sup>®</sup>/bone, Facilitate™/mucosa, Facilitate™/bone, or mental navigation or a pilot‐drill template. The precision was assessed by matching the planning computed tomography (CT) with a post‐operative cone beam CT.</p> </sec> <sec id="jcpe12231-sec-0003" sec-type="section"> <title>Results</title> <p>A significant lower mean deviation at the entry point (1.4 mm, range: 0.3–3.7), at the apex (1.6 mm, range: 0.2–3.7) and angular deviation (3.0°, range: 0.2–16°) was observed for the guiding systems when compared to mental navigation (2.7 mm, range: 0.3–8.3; 2.9 mm, range: 0.5–7.4 and 9.9°, range: 1.5–27.8) and to the surgical template group (3.0 mm, range: 0.6–6.6; 3.4 mm, range: 0.3–7.5 and 8.4°, range: 0.6–21.3°). Differences between bone and mucosa support or type of guidance were negligible. Jaw and implant location (posterior–anterior, left–right), however, had a significant influence on the accuracy when guided.</p> </sec> <sec id="jcpe12231-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Based on these findings, guided implant placement appears to offer clear accuracy benefits.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of clinical periodontology. Volume 41:Number 7(2014:Jul.)
- Journal:
- Journal of clinical periodontology
- Issue:
- Volume 41:Number 7(2014:Jul.)
- Issue Display:
- Volume 41, Issue 7 (2014)
- Year:
- 2014
- Volume:
- 41
- Issue:
- 7
- Issue Sort Value:
- 2014-0041-0007-0000
- Page Start:
- 717
- Page End:
- 723
- Publication Date:
- 2014-04-10
- Subjects:
- Periodontics -- Periodicals
617.6 - Journal URLs:
- http://www.blackwell-synergy.com/loi/cpe ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1600-051X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jcpe.12231 ↗
- Languages:
- English
- ISSNs:
- 0303-6979
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.672000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3184.xml