Assessment of pregnancy-associated, within-woman change in uterine length. (July 2014)
- Record Type:
- Journal Article
- Title:
- Assessment of pregnancy-associated, within-woman change in uterine length. (July 2014)
- Main Title:
- Assessment of pregnancy-associated, within-woman change in uterine length
- Authors:
- Hawkins, Leah K.
Missmer, Stacey A.
Correia, Katharine F.
Hornstein, Mark D. - Abstract:
- <abstract> <title>Abstract</title> <p> <italic>Objective</italic>: To evaluate how absolute uterine length changes as a result of pregnancy.</p> <p> <italic>Methods</italic>: Longitudinal repeated-measures study of all women presenting to a university-affiliated clinic for uterine sounding prior to <italic>in vitro</italic> fertilization (IVF) who went on to deliver at term and return for repeat measurement from 2002 to 2012. Change in uterine length was assessed by the Wilcoxon signed-rank test.</p> <p> <italic>Results</italic>: Among 495 women, mean pregnancy-associated change in uterine length was 0.0 cm (SD ± 0.7, <italic>p</italic> = 0.84), with 31% of women experiencing no change and 75% of women experiencing a change ≤0.5 cm. Mean uterine lengths at pre-cycle and repeat measurement were 7.2 cm (SD ± 0.7) and 7.2 cm (SD ± 0.7) with medians of 7.0 cm (IQR 7.0–7.5) and 7.0 cm (IQR 6.8–7.8), respectively. Change in uterine length did not vary by gestational number or within time interval between measurements (all <italic>p</italic> &gt; 0.5).</p> <p> <italic>Conclusions</italic>: There was no difference in uterine length before and after term pregnancy. The finding of minimal variation in uterine length both across and within women suggests uterine length may be relatively stable such that patients undergoing IVF after term IVF pregnancy may not require repeat measurement. Future studies might assess pregnancy-associated sonographic changes in uterine volume and the<abstract> <title>Abstract</title> <p> <italic>Objective</italic>: To evaluate how absolute uterine length changes as a result of pregnancy.</p> <p> <italic>Methods</italic>: Longitudinal repeated-measures study of all women presenting to a university-affiliated clinic for uterine sounding prior to <italic>in vitro</italic> fertilization (IVF) who went on to deliver at term and return for repeat measurement from 2002 to 2012. Change in uterine length was assessed by the Wilcoxon signed-rank test.</p> <p> <italic>Results</italic>: Among 495 women, mean pregnancy-associated change in uterine length was 0.0 cm (SD ± 0.7, <italic>p</italic> = 0.84), with 31% of women experiencing no change and 75% of women experiencing a change ≤0.5 cm. Mean uterine lengths at pre-cycle and repeat measurement were 7.2 cm (SD ± 0.7) and 7.2 cm (SD ± 0.7) with medians of 7.0 cm (IQR 7.0–7.5) and 7.0 cm (IQR 6.8–7.8), respectively. Change in uterine length did not vary by gestational number or within time interval between measurements (all <italic>p</italic> &gt; 0.5).</p> <p> <italic>Conclusions</italic>: There was no difference in uterine length before and after term pregnancy. The finding of minimal variation in uterine length both across and within women suggests uterine length may be relatively stable such that patients undergoing IVF after term IVF pregnancy may not require repeat measurement. Future studies might assess pregnancy-associated sonographic changes in uterine volume and the relationship between uterine length and IVF outcomes.</p> </abstract> … (more)
- Is Part Of:
- Journal of maternal-fetal & neonatal medicine. Volume 27:Number 10(2014:Oct.)
- Journal:
- Journal of maternal-fetal & neonatal medicine
- Issue:
- Volume 27:Number 10(2014:Oct.)
- Issue Display:
- Volume 27, Issue 10 (2014)
- Year:
- 2014
- Volume:
- 27
- Issue:
- 10
- Issue Sort Value:
- 2014-0027-0010-0000
- Page Start:
- 989
- Page End:
- 993
- Publication Date:
- 2014-07
- Subjects:
- Obstetrics -- Periodicals
Perinatology -- Periodicals
Infants (Newborn) -- Diseases -- Periodicals
Neonatology -- Periodicals
618.2 - Journal URLs:
- http://informahealthcare.com/loi/jmf ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/14767058.2013.853732 ↗
- Languages:
- English
- ISSNs:
- 1476-7058
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5012.332000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3945.xml