Stereo-Acuity in Patients Implanted with Multifocal Intraocular Lenses: Is the Choice of Stereotest Relevant?. (July 2014)
- Record Type:
- Journal Article
- Title:
- Stereo-Acuity in Patients Implanted with Multifocal Intraocular Lenses: Is the Choice of Stereotest Relevant?. (July 2014)
- Main Title:
- Stereo-Acuity in Patients Implanted with Multifocal Intraocular Lenses: Is the Choice of Stereotest Relevant?
- Authors:
- Varón, Consuelo
Gil, Miguel A.
Alba-Bueno, Francisco
Cardona, Genís
Vega, Fidel
Millán, María S.
Buil, José A. - Abstract:
- <abstract> <title>Abstract</title> <p> <italic>Purpose</italic>: A randomized and double-blinded study design was implemented to assess the stereo-acuity in patients symmetrically implanted with four types of multifocal intraocular lenses (MIOLs), compared to a monofocal lens (control group). In addition, the influence of the type of test employed for the evaluation of stereo-acuity was explored.</p> <p> <italic>Materials and Methods</italic>: Six months after cataract intervention, stereo-acuity was measured with the Titmus and TNO stereotests in 143 patients implanted with one of the following MIOL lens types: hybrid spherical SN60D3, hybrid aspheric SN6AD1, diffractive aspheric ZMA00 and refractive spherical NXG1. A control group implanted with the monofocal aspheric ZA9003 (in which stereo-acuity was measured with a near addition) was also included in the study.</p> <p> <italic>Results</italic>: Statistically significant better stereo-acuity was found in the monofocal group with both stereotests (except for the SN60D3 group with the Titmus test) (all <italic>p</italic> &lt; 0.001). No significant differences in stereo-acuity between MIOLs were found using the Titmus test. However, with the TNO, patients implanted with hybrid diffractive MIOLs exhibited statistically significant worse stereo-acuity than those with the refractive design (SN60D3, <italic>p</italic> &lt; 0.001; SN6AD1, <italic>p</italic> = 0.006).</p> <p> <italic>Conclusions</italic>: Patients implanted with<abstract> <title>Abstract</title> <p> <italic>Purpose</italic>: A randomized and double-blinded study design was implemented to assess the stereo-acuity in patients symmetrically implanted with four types of multifocal intraocular lenses (MIOLs), compared to a monofocal lens (control group). In addition, the influence of the type of test employed for the evaluation of stereo-acuity was explored.</p> <p> <italic>Materials and Methods</italic>: Six months after cataract intervention, stereo-acuity was measured with the Titmus and TNO stereotests in 143 patients implanted with one of the following MIOL lens types: hybrid spherical SN60D3, hybrid aspheric SN6AD1, diffractive aspheric ZMA00 and refractive spherical NXG1. A control group implanted with the monofocal aspheric ZA9003 (in which stereo-acuity was measured with a near addition) was also included in the study.</p> <p> <italic>Results</italic>: Statistically significant better stereo-acuity was found in the monofocal group with both stereotests (except for the SN60D3 group with the Titmus test) (all <italic>p</italic> &lt; 0.001). No significant differences in stereo-acuity between MIOLs were found using the Titmus test. However, with the TNO, patients implanted with hybrid diffractive MIOLs exhibited statistically significant worse stereo-acuity than those with the refractive design (SN60D3, <italic>p</italic> &lt; 0.001; SN6AD1, <italic>p</italic> = 0.006).</p> <p> <italic>Conclusions</italic>: Patients implanted with MIOLs have worse stereo-acuity than those implanted with monofocal IOLs due to the decrease in retinal image contrast originating in the simultaneous presence of two images. A wavelength-based stereotest such as the TNO induces large differences in image contrast between fellow eyes implanted with diffractive-based MIOLs, which may result in an underestimation of the real stereo-acuity of the patient.</p> </abstract> … (more)
- Is Part Of:
- Current eye research. Volume 39:Number 7(2014:Jul.)
- Journal:
- Current eye research
- Issue:
- Volume 39:Number 7(2014:Jul.)
- Issue Display:
- Volume 39, Issue 7 (2014)
- Year:
- 2014
- Volume:
- 39
- Issue:
- 7
- Issue Sort Value:
- 2014-0039-0007-0000
- Page Start:
- 711
- Page End:
- 719
- Publication Date:
- 2014-07
- Subjects:
- Ophthalmology -- Periodicals
Eye -- Diseases -- Periodicals
Ophthalmology -- Periodicals
573.88 - Journal URLs:
- http://informahealthcare.com/journal/cey ↗
http://www.tandfonline.com/toc/icey20/current ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/02713683.2013.865758 ↗
- Languages:
- English
- ISSNs:
- 0271-3683
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3496.570000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3847.xml