In vitro hypercoagulability on whole blood thromboelastometry associated with in vivo reduction of circulating red cell mass in dogs. (3rd March 2014)
- Record Type:
- Journal Article
- Title:
- In vitro hypercoagulability on whole blood thromboelastometry associated with in vivo reduction of circulating red cell mass in dogs. (3rd March 2014)
- Main Title:
- In vitro hypercoagulability on whole blood thromboelastometry associated with in vivo reduction of circulating red cell mass in dogs
- Authors:
- McMichael, Maureen A.
Smith, Stephanie A.
Galligan, Alyssa
Swanson, Kelly S. - Abstract:
- <abstract abstract-type="main" id="vcp12127-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="vcp12127-sec-0001" sec-type="section"> <title>Background</title> <p>Previous studies have reported a strong correlation between indicators of red cell mass (RCM) and thromboelastometry results (TEM) in several species, specifically an association of apparent hypercoagulability with decreased RCM.</p> </sec> <sec id="vcp12127-sec-0002" sec-type="section"> <title>Objectives</title> <p>The objectives of the study were to (1) evaluate the effect of decreased circulating RCM on TEM results in dogs, and (2) determine the relative contributions of citrate dilution vs in vivo reduction of RCM to hemostatic potential.</p> </sec> <sec id="vcp12127-sec-0003" sec-type="section"> <title>Materials and Methods</title> <p>Thirteen healthy dogs had one unit of blood removed on day 0. Whole blood, EDTA, and citrated blood samples for evaluation of TEM variables and PT, APTT, platelet count, fibrinogen, thrombin–antithrombin (TAT), and thrombin generation were collected at baseline, and 3 and 21 days after blood removal. Blood samples were also corrected to a PCV of 45% by adding citrate or removing plasma.</p> </sec> <sec id="vcp12127-sec-0004" sec-type="section"> <title>Results</title> <p>On day 3 after blood removal, the PCV was significantly decreased (45 ± 6%) compared with baseline (52 ± 6%) and day 21 (50 ± 4%, <italic>P</italic> &lt; .001), accompanied by TEM variables<abstract abstract-type="main" id="vcp12127-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="vcp12127-sec-0001" sec-type="section"> <title>Background</title> <p>Previous studies have reported a strong correlation between indicators of red cell mass (RCM) and thromboelastometry results (TEM) in several species, specifically an association of apparent hypercoagulability with decreased RCM.</p> </sec> <sec id="vcp12127-sec-0002" sec-type="section"> <title>Objectives</title> <p>The objectives of the study were to (1) evaluate the effect of decreased circulating RCM on TEM results in dogs, and (2) determine the relative contributions of citrate dilution vs in vivo reduction of RCM to hemostatic potential.</p> </sec> <sec id="vcp12127-sec-0003" sec-type="section"> <title>Materials and Methods</title> <p>Thirteen healthy dogs had one unit of blood removed on day 0. Whole blood, EDTA, and citrated blood samples for evaluation of TEM variables and PT, APTT, platelet count, fibrinogen, thrombin–antithrombin (TAT), and thrombin generation were collected at baseline, and 3 and 21 days after blood removal. Blood samples were also corrected to a PCV of 45% by adding citrate or removing plasma.</p> </sec> <sec id="vcp12127-sec-0004" sec-type="section"> <title>Results</title> <p>On day 3 after blood removal, the PCV was significantly decreased (45 ± 6%) compared with baseline (52 ± 6%) and day 21 (50 ± 4%, <italic>P</italic> &lt; .001), accompanied by TEM variables indicating hypercoagulability, which returned to baseline values by day 21. Other coagulation variables such as PT, APTT, platelet count, TAT, or plasma thrombin generation remained unchanged, with the exception of fibrinogen that was significantly higher on day 3. No changes were related to citrate dilution.</p> </sec> <sec id="vcp12127-sec-0005" sec-type="section"> <title>Conclusions</title> <p>Transiently decreased RCM in vivo was accompanied by TEM variables indicating hypercoagulability, which was not confirmed by other coagulation variables. This suggests an artifact of TEM, which presents a potential limitation of this technology in patient populations with abnormal RCM.</p> </sec> </abstract> … (more)
- Is Part Of:
- Veterinary clinical pathology. Volume 43:Number 2(2014)
- Journal:
- Veterinary clinical pathology
- Issue:
- Volume 43:Number 2(2014)
- Issue Display:
- Volume 43, Issue 2 (2014)
- Year:
- 2014
- Volume:
- 43
- Issue:
- 2
- Issue Sort Value:
- 2014-0043-0002-0000
- Page Start:
- 154
- Page End:
- 163
- Publication Date:
- 2014-03-03
- Subjects:
- Veterinary pathology -- Periodicals
636.089607 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/vcp.12127 ↗
- Languages:
- English
- ISSNs:
- 0275-6382
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9227.015500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3694.xml