Feasibility of using Auto Mod‐MPI system, a novel technique for automated measurement of fetal modified myocardial performance index. (June 2014)
- Record Type:
- Journal Article
- Title:
- Feasibility of using Auto Mod‐MPI system, a novel technique for automated measurement of fetal modified myocardial performance index. (June 2014)
- Main Title:
- Feasibility of using Auto Mod‐MPI system, a novel technique for automated measurement of fetal modified myocardial performance index
- Authors:
- Lee, M.‐Y.
Won, H.‐S.
Jeon, E.‐J.
Yoon, H. C.
Choi, J. Y.
Hong, S. J.
Kim, M.‐J. - Abstract:
- <abstract abstract-type="main" id="uog13247-abs-0001"> <title>ABSTRACT</title> <sec id="uog13247-sec-0001" sec-type="section"> <title>Objectives</title> <p id="uog13247-para-0001"> <italic>To evaluate the reproducibility of measurement of the fetal left modified myocardial performance index (Mod‐MPI) determined using a novel automated system</italic>.</p> </sec> <sec id="uog13247-sec-0002" sec-type="section"> <title>Methods</title> <p id="uog13247-para-0002"> <italic>This was a prospective study of 116 ultrasound examinations from 110 normal singleton pregnancies at 12 + 1 to 37 + 1 weeks' gestation. Two experienced operators each measured the left Mod‐MPI twice manually and twice automatically using the Auto Mod‐MPI system. Intra‐ and interoperator reproducibility were assessed using intraclass correlation coefficients (ICCs) and the manual and automated measurements obtained by the more experienced operator were compared using Bland–Altman plots and ICCs</italic>.</p> </sec> <sec id="uog13247-sec-0003" sec-type="section"> <title>Results</title> <p id="uog13247-para-0003"> <italic>Both operators successfully measured the left Mod‐MPI in all cases using the Auto Mod‐MPI system. For both operators, intraoperator reproducibility was higher when performing automated measurements (ICC = 0.967 and 0.962 for Operators 1 and 2, respectively) than when performing manual measurements (ICC = 0.857 and 0.856 for Operators 1 and 2, respectively). Interoperator agreement was also better<abstract abstract-type="main" id="uog13247-abs-0001"> <title>ABSTRACT</title> <sec id="uog13247-sec-0001" sec-type="section"> <title>Objectives</title> <p id="uog13247-para-0001"> <italic>To evaluate the reproducibility of measurement of the fetal left modified myocardial performance index (Mod‐MPI) determined using a novel automated system</italic>.</p> </sec> <sec id="uog13247-sec-0002" sec-type="section"> <title>Methods</title> <p id="uog13247-para-0002"> <italic>This was a prospective study of 116 ultrasound examinations from 110 normal singleton pregnancies at 12 + 1 to 37 + 1 weeks' gestation. Two experienced operators each measured the left Mod‐MPI twice manually and twice automatically using the Auto Mod‐MPI system. Intra‐ and interoperator reproducibility were assessed using intraclass correlation coefficients (ICCs) and the manual and automated measurements obtained by the more experienced operator were compared using Bland–Altman plots and ICCs</italic>.</p> </sec> <sec id="uog13247-sec-0003" sec-type="section"> <title>Results</title> <p id="uog13247-para-0003"> <italic>Both operators successfully measured the left Mod‐MPI in all cases using the Auto Mod‐MPI system. For both operators, intraoperator reproducibility was higher when performing automated measurements (ICC = 0.967 and 0.962 for Operators 1 and 2, respectively) than when performing manual measurements (ICC = 0.857 and 0.856 for Operators 1 and 2, respectively). Interoperator agreement was also better for automated than for manual measurements (ICC = 0.930</italic> <italic>vs</italic> <italic>0.723, respectively). There was good agreement between the automated and manual values measured by the more experienced operator</italic>.</p> </sec> <sec id="uog13247-sec-0004" sec-type="section"> <title>Conclusions</title> <p id="uog13247-para-0004"> <italic>The Auto Mod‐MPI system is a reliable technique for measuring fetal left Mod‐MPI and demonstrates excellent reproducibility. Copyright © 2013 ISUOG. Published by John Wiley &amp; Sons Ltd</italic>.</p> </sec> </abstract> … (more)
- Is Part Of:
- Ultrasound in obstetrics & gynecology. Volume 43:Number 6(2014:Jun.)
- Journal:
- Ultrasound in obstetrics & gynecology
- Issue:
- Volume 43:Number 6(2014:Jun.)
- Issue Display:
- Volume 43, Issue 6 (2014)
- Year:
- 2014
- Volume:
- 43
- Issue:
- 6
- Issue Sort Value:
- 2014-0043-0006-0000
- Page Start:
- 640
- Page End:
- 645
- Publication Date:
- 2014-06
- Subjects:
- Ultrasonics in obstetrics -- Periodicals
Generative organs, Female -- Diseases -- Diagnosis -- Periodicals
Diagnosis, Ultrasonic -- Periodicals
Genital Diseases, Female -- ultrasonography -- Periodicals
Ultrasonography, Prenatal -- Periodicals
618.047543 - Journal URLs:
- http://obgyn.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1469-0705/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/uog.13247 ↗
- Languages:
- English
- ISSNs:
- 0960-7692
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9082.815300
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3035.xml