Comparing four volumetric modulated arc therapy beam arrangements for the treatment of early‐stage prostate cancer. Issue 2 (20th May 2014)
- Record Type:
- Journal Article
- Title:
- Comparing four volumetric modulated arc therapy beam arrangements for the treatment of early‐stage prostate cancer. Issue 2 (20th May 2014)
- Main Title:
- Comparing four volumetric modulated arc therapy beam arrangements for the treatment of early‐stage prostate cancer
- Authors:
- Elith, Craig A.
Dempsey, Shane E.
Warren‐Forward, Helen M. - Abstract:
- <abstract abstract-type="main" id="jmrs52-abs-0001"> <title>Abstract</title> <sec id="jmrs52-sec-0001" sec-type="section"> <title>Introduction</title> <p>This study compared four different volumetric modulated arc therapy (VMAT) beam arrangements for the treatment of early‐stage prostate cancer examining plan quality and the impact on a radiotherapy department's resources.</p> </sec> <sec id="jmrs52-sec-0002" sec-type="section"> <title>Methods</title> <p>Twenty prostate cases were retrospectively planned using four VMAT beam arrangements (1) a partial arc (PA), (2) one arc (1A), (3) one arc plus a partial arc (1A + PA) and (4) two arcs (2A). The quality of the dose distributions generated were compared by examining the overall plan quality, the homogeneity and conformity to the planning target volume (PTV), the number of monitor units and the dose delivered to the organs at risk. Departmental resources were considered by recording the planning time and beam delivery time.</p> </sec> <sec id="jmrs52-sec-0003" sec-type="section"> <title>Results</title> <p>Each technique produced a plan of similar quality that was considered adequate for treatment; though some differences were noted. The 1A, 1A + PA and 2A plans demonstrated a better conformity to the PTV which correlated to improved sparing of the rectum in the 60–70 Gy range for the 1A + PA and 2A techniques. The time needed to generate the plans was different for each technique ranging from 13.1 min for 1A + PA to 17.8 min<abstract abstract-type="main" id="jmrs52-abs-0001"> <title>Abstract</title> <sec id="jmrs52-sec-0001" sec-type="section"> <title>Introduction</title> <p>This study compared four different volumetric modulated arc therapy (VMAT) beam arrangements for the treatment of early‐stage prostate cancer examining plan quality and the impact on a radiotherapy department's resources.</p> </sec> <sec id="jmrs52-sec-0002" sec-type="section"> <title>Methods</title> <p>Twenty prostate cases were retrospectively planned using four VMAT beam arrangements (1) a partial arc (PA), (2) one arc (1A), (3) one arc plus a partial arc (1A + PA) and (4) two arcs (2A). The quality of the dose distributions generated were compared by examining the overall plan quality, the homogeneity and conformity to the planning target volume (PTV), the number of monitor units and the dose delivered to the organs at risk. Departmental resources were considered by recording the planning time and beam delivery time.</p> </sec> <sec id="jmrs52-sec-0003" sec-type="section"> <title>Results</title> <p>Each technique produced a plan of similar quality that was considered adequate for treatment; though some differences were noted. The 1A, 1A + PA and 2A plans demonstrated a better conformity to the PTV which correlated to improved sparing of the rectum in the 60–70 Gy range for the 1A + PA and 2A techniques. The time needed to generate the plans was different for each technique ranging from 13.1 min for 1A + PA to 17.8 min for 1A. The PA beam delivery time was fastest with a mean time of 0.9 min. Beam‐on times then increased with an increase in the number of arcs up to an average of 2.2 min for the 2A technique.</p> </sec> <sec id="jmrs52-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Which VMAT technique is best suited for clinical implementation for the treatment of prostate cancer may be dictated by the individual patient and the availability of departmental resources.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of medical radiation sciences. Volume 61:Issue 2(2014:Jun.)
- Journal:
- Journal of medical radiation sciences
- Issue:
- Volume 61:Issue 2(2014:Jun.)
- Issue Display:
- Volume 61, Issue 2 (2014)
- Year:
- 2014
- Volume:
- 61
- Issue:
- 2
- Issue Sort Value:
- 2014-0061-0002-0000
- Page Start:
- 91
- Page End:
- 101
- Publication Date:
- 2014-05-20
- Subjects:
- Radiology, Medical -- Periodicals
Radiology, Medical -- Australia -- Periodicals
Radiology, Medical -- New Zealand -- Periodicals
Radiotherapy -- Periodicals
Diagnostic imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2051-3909 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmrs.52 ↗
- Languages:
- English
- ISSNs:
- 2051-3895
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4363.xml