Improved visualisation of cervix applicators for magnetic resonance-only-guided brachytherapy planning. Issue 2 (22nd January 2014)
- Record Type:
- Journal Article
- Title:
- Improved visualisation of cervix applicators for magnetic resonance-only-guided brachytherapy planning. Issue 2 (22nd January 2014)
- Main Title:
- Improved visualisation of cervix applicators for magnetic resonance-only-guided brachytherapy planning
- Authors:
- Liney, Gary P.
Marsden, Jenny E.
Horsfield, Carl J.
Murray, Tom
Manton, David J.
Beavis, Andrew W. - Abstract:
- <abstract abstract-type="normal"> <title>Abstract</title> <sec id="abs1" sec-type="general"> <title>Objectives</title> <p>Current guidelines for image-guided cervical cancer brachytherapy planning recommend both computed tomography (CT) and magnetic resonance imaging (MRI) for adequate visualisation of the applicator and soft tissues, respectively. MRI-only planning would be ideal as it would save time within the patient pathway and avoid the concomitant CT exposures. However, applicator visualisation on MRI is usually achieved using fluid-filled fiducial marker tubes, which can be awkward to use and suffer from unwanted air bubble artefacts. Therefore, a new fiducial-free imaging technique was developed.</p> </sec> <sec id="abs2" sec-type="methods"> <title>Methods</title> <p>A dual echo time (TE) turbo spin echo sequence was used, at 1·5 T, to provide both T<sub>2</sub>-weighted images (100 ms TE) for tissue visualisation and strongly proton density-weighted images (17 ms TE) for improved applicator visualisation. In-house software was used to automatically segment the applicator in the short TE images (using Otsu's method) and transfer the information to the long TE images to provide a single fused dataset.</p> </sec> <sec id="abs3" sec-type="results"> <title>Results</title> <p>The method was evaluated successfully using titanium applicators in three patient cases and using a plastic applicator in a tissue-equivalent gel phantom.</p> </sec> <sec id="abs4"<abstract abstract-type="normal"> <title>Abstract</title> <sec id="abs1" sec-type="general"> <title>Objectives</title> <p>Current guidelines for image-guided cervical cancer brachytherapy planning recommend both computed tomography (CT) and magnetic resonance imaging (MRI) for adequate visualisation of the applicator and soft tissues, respectively. MRI-only planning would be ideal as it would save time within the patient pathway and avoid the concomitant CT exposures. However, applicator visualisation on MRI is usually achieved using fluid-filled fiducial marker tubes, which can be awkward to use and suffer from unwanted air bubble artefacts. Therefore, a new fiducial-free imaging technique was developed.</p> </sec> <sec id="abs2" sec-type="methods"> <title>Methods</title> <p>A dual echo time (TE) turbo spin echo sequence was used, at 1·5 T, to provide both T<sub>2</sub>-weighted images (100 ms TE) for tissue visualisation and strongly proton density-weighted images (17 ms TE) for improved applicator visualisation. In-house software was used to automatically segment the applicator in the short TE images (using Otsu's method) and transfer the information to the long TE images to provide a single fused dataset.</p> </sec> <sec id="abs3" sec-type="results"> <title>Results</title> <p>The method was evaluated successfully using titanium applicators in three patient cases and using a plastic applicator in a tissue-equivalent gel phantom.</p> </sec> <sec id="abs4" sec-type="conclusion"> <title>Conclusions</title> <p>The dual-echo technique provides a simple and efficient method for improving the visualisation of brachytherapy applicators in cervical cancer MRI images without the need for marker tubes.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of radiotherapy in practice. Volume 13:Issue 2(2013)
- Journal:
- Journal of radiotherapy in practice
- Issue:
- Volume 13:Issue 2(2013)
- Issue Display:
- Volume 13, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 13
- Issue:
- 2
- Issue Sort Value:
- 2013-0013-0002-0000
- Page Start:
- 159
- Page End:
- 165
- Publication Date:
- 2014-01-22
- Subjects:
- Radiotherapy -- Periodicals
615.842005 - Journal URLs:
- http://journals.cambridge.org/action/displayJournal?jid=JRP ↗
- DOI:
- 10.1017/S1460396913000514 ↗
- Languages:
- English
- ISSNs:
- 1460-3969
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 4291.xml