Could mini-PET be used to instead of 4 h original-PET to assess peritoneal permeability in children on peritoneal dialysis?. (May 2014)
- Record Type:
- Journal Article
- Title:
- Could mini-PET be used to instead of 4 h original-PET to assess peritoneal permeability in children on peritoneal dialysis?. (May 2014)
- Main Title:
- Could mini-PET be used to instead of 4 h original-PET to assess peritoneal permeability in children on peritoneal dialysis?
- Authors:
- Baştuğ, Funda
Dursun, İsmail
Dursun, Jale
Gündüz, Zübeyde
Günay, Demet
Yel, Sibel
Düşünsel, Ruhan
Bolat, Sibel
Yılmaz, Kenan
Tülpar, Sebahat
Poyrazoglu, Hakan - Abstract:
- <abstract> <title>Abstract</title> <p> <italic>Background: </italic>Original peritoneal equilibration test (PET) is an implementation that requires hard work for peritoneal dialysis (PD) staff. Therefore, several authors have attempted to validate short and fast PET protocols, with controversial results. The aim of this study was to evaluate the concordance between the mini-PET and original PET in children. <italic>Methods:</italic> In 26 stable continuous ambulatory PD patients, we performed an original PET with 2.27% (4 h) and a mini-PET with 3.86% glucose PD fluid (1 h) and compared ultrafiltration (UF) and small solute transports obtained with the two methods. <italic>Results: </italic>Twenty-six children, 14 males, mean age 11.4 ± 5.6 (range 2.5–19 years), were included. Meantime on PD at time of enrollment was 35.2 ± 24.5 months (range 6–84 months). Based on the 4-h creatinine D/P data, the number of the patients within each transport category was as follow: high, 5; average, 18; low, 3. Kappa test showed a significant concordance between original PET and mini-PET (<italic>k</italic> = 0.610). Based on the 4-h glucose D/D<sub>0</sub> data, the number of the patients within each transport category was as follow: high, 5; average, 17; low, 4. Kappa test showed a moderate agreement between original PET and mini-PET (0.514, <italic>p = </italic>0.000). When Pearson correlation analysis between original PET and mini-PET was performed, there were significant positive<abstract> <title>Abstract</title> <p> <italic>Background: </italic>Original peritoneal equilibration test (PET) is an implementation that requires hard work for peritoneal dialysis (PD) staff. Therefore, several authors have attempted to validate short and fast PET protocols, with controversial results. The aim of this study was to evaluate the concordance between the mini-PET and original PET in children. <italic>Methods:</italic> In 26 stable continuous ambulatory PD patients, we performed an original PET with 2.27% (4 h) and a mini-PET with 3.86% glucose PD fluid (1 h) and compared ultrafiltration (UF) and small solute transports obtained with the two methods. <italic>Results: </italic>Twenty-six children, 14 males, mean age 11.4 ± 5.6 (range 2.5–19 years), were included. Meantime on PD at time of enrollment was 35.2 ± 24.5 months (range 6–84 months). Based on the 4-h creatinine D/P data, the number of the patients within each transport category was as follow: high, 5; average, 18; low, 3. Kappa test showed a significant concordance between original PET and mini-PET (<italic>k</italic> = 0.610). Based on the 4-h glucose D/D<sub>0</sub> data, the number of the patients within each transport category was as follow: high, 5; average, 17; low, 4. Kappa test showed a moderate agreement between original PET and mini-PET (0.514, <italic>p = </italic>0.000). When Pearson correlation analysis between original PET and mini-PET was performed, there were significant positive correlations between original 2.27% PET and mini-PET (<italic>r</italic> = 0.720, <italic>p = </italic>0.000, <italic>r</italic> = 0.638, <italic>p = </italic>0.000, respectively). When comparing the numeric results of mini-PET and 4 h of original PET for D/C<sub>reatinine</sub>, by simple regression analysis, we found statistically significant correlation among PETs. <italic>Conclusions:</italic> In this study, we showed concordance between the mini-PET and original PET. The 3.86% mini-PET is simple and fast methods to assess free water transport. This also gives information about total UF and small solute transports and it is in good agreement with the original PET.</p> </abstract> … (more)
- Is Part Of:
- Renal failure. Volume 36:Number 4(2014)
- Journal:
- Renal failure
- Issue:
- Volume 36:Number 4(2014)
- Issue Display:
- Volume 36, Issue 4 (2014)
- Year:
- 2014
- Volume:
- 36
- Issue:
- 4
- Issue Sort Value:
- 2014-0036-0004-0000
- Page Start:
- 562
- Page End:
- 566
- Publication Date:
- 2014-05
- Subjects:
- Chronic renal failure -- Periodicals
Acute renal failure -- Periodicals
Uremia -- Periodicals
616.614005 - Journal URLs:
- http://informahealthcare.com/journal/rnf ↗
http://informahealthcare.com ↗
http://www.tandf.co.uk/journals/titles/0886022x.asp ↗ - DOI:
- 10.3109/0886022X.2013.879368 ↗
- Languages:
- English
- ISSNs:
- 0886-022X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7356.869800
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3335.xml