FiberNet—A new embolic protection device for carotid artery stenting. Issue 6 (9th November 2013)
- Record Type:
- Journal Article
- Title:
- FiberNet—A new embolic protection device for carotid artery stenting. Issue 6 (9th November 2013)
- Main Title:
- FiberNet—A new embolic protection device for carotid artery stenting
- Authors:
- Bauer, C.
Franke, J.
Bertog, S.C.
Woerner, V.
Ghasemzadeh‐Asl, S.
Sievert, H. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd25138-sec-0001" sec-type="section"> <title>Background</title> <p>Though distal filter protection during carotid stenting reduces the risk of cerebrovascular events, periprocedural stroke remains a risk despite their broad usage. This observation may be related to the pore size of common filters. The FiberNet distal filter system is unique by its very small pore size (40 µm) as well as its low profile and flexibility. Little data is available regarding the clinical performance and safety of this device.</p> </sec> <sec id="ccd25138-sec-0002" sec-type="section"> <title>Purpose</title> <p>The aim was the evaluation of the safety of the FiberNet embolic protection system during carotid artery stenting.</p> </sec> <sec id="ccd25138-sec-0003" sec-type="section"> <title>Methods</title> <p>All consecutive patients treated with carotid stenting at our institution using the FiberNet device were systematically followed. Primary endpoint was the rate of all death and stroke within 30 days of the procedure.</p> </sec> <sec id="ccd25138-sec-0004" sec-type="section"> <title>Results</title> <p>Carotid artery stenting using the FiberNet embolic protection system was performed in 54 patients. The procedure was technical successful in all patients. Three patients (5.5%) had a TIA. Amauosis fugax occurred in two patients (3.7%). One patient (1.9%) had a minor stroke with hemiparesis of the left arm<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd25138-sec-0001" sec-type="section"> <title>Background</title> <p>Though distal filter protection during carotid stenting reduces the risk of cerebrovascular events, periprocedural stroke remains a risk despite their broad usage. This observation may be related to the pore size of common filters. The FiberNet distal filter system is unique by its very small pore size (40 µm) as well as its low profile and flexibility. Little data is available regarding the clinical performance and safety of this device.</p> </sec> <sec id="ccd25138-sec-0002" sec-type="section"> <title>Purpose</title> <p>The aim was the evaluation of the safety of the FiberNet embolic protection system during carotid artery stenting.</p> </sec> <sec id="ccd25138-sec-0003" sec-type="section"> <title>Methods</title> <p>All consecutive patients treated with carotid stenting at our institution using the FiberNet device were systematically followed. Primary endpoint was the rate of all death and stroke within 30 days of the procedure.</p> </sec> <sec id="ccd25138-sec-0004" sec-type="section"> <title>Results</title> <p>Carotid artery stenting using the FiberNet embolic protection system was performed in 54 patients. The procedure was technical successful in all patients. Three patients (5.5%) had a TIA. Amauosis fugax occurred in two patients (3.7%). One patient (1.9%) had a minor stroke with hemiparesis of the left arm and face which resolved completely within 48 hr after the procedure. No patient died or suffered a major stroke.</p> </sec> <sec id="ccd25138-sec-0005" sec-type="section"> <title>Conclusion</title> <p>The safety and feasibility of the FiberNet distal protection system appears to be at least equivalent to that reported in studies using conventional distal filter protection. © 2013 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 83:Issue 6(2014:May 01)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 83:Issue 6(2014:May 01)
- Issue Display:
- Volume 83, Issue 6 (2014)
- Year:
- 2014
- Volume:
- 83
- Issue:
- 6
- Issue Sort Value:
- 2014-0083-0006-0000
- Page Start:
- 1014
- Page End:
- 1020
- Publication Date:
- 2013-11-09
- Subjects:
- Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.25138 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2976.xml