Safety and efficacy of preoperative autologous blood donation for high‐risk pregnant women: Experience of a large university hospital in Japan. Issue 5 (21st April 2014)
- Record Type:
- Journal Article
- Title:
- Safety and efficacy of preoperative autologous blood donation for high‐risk pregnant women: Experience of a large university hospital in Japan. Issue 5 (21st April 2014)
- Main Title:
- Safety and efficacy of preoperative autologous blood donation for high‐risk pregnant women: Experience of a large university hospital in Japan
- Authors:
- Yamamoto, Yasuhiro
Yamashita, Takahiro
Tsuno, Nelson Hirokazu
Nagamatsu, Takeshi
Okochi, Naoko
Hyodo, Hironobu
Ikeda, Toshiyuki
Kawabata, Michiru
Kamei, Yoshimasa
Nagura, Yutaka
Sone, Shinji
Fujii, Tomoyuki
Takahashi, Koki
Kozuma, Shiro - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <sec id="jog12348-sec-0001" sec-type="section"> <title>Aim</title> <p>Preoperative autologous blood donation (PAD) has the advantages over allogeneic blood transfusion of theoretically no risk of viral infection and alloimmunization. However, there are some concerns regarding PAD in pregnant women, as they sometimes become anemic and adverse effects such as low blood pressure could be harmful to fetuses. In our hospital, the PAD program was implemented in 2006 and has been used in pregnant women at high risk of massive hemorrhage. In this study, the safety of PAD in pregnant women and its efficacy for avoiding allogeneic blood transfusion were investigated.</p> </sec> <sec id="jog12348-sec-0002" sec-type="section"> <title>Methods</title> <p>The hospital records of pregnant women who delivered at our hospital from January 2009 to June 2012 were reviewed and those who were enrolled in the PAD program for predicted massive hemorrhage were analyzed.</p> </sec> <sec id="jog12348-sec-0003" sec-type="section"> <title>Results</title> <p>Among the total of 3095 deliveries, 69 cases enrolled in the PAD program were analyzed. Blood donation was performed 189 times for the 69 cases. The median donated blood volume was 1200 mL (range, 400–2000). The mean blood loss during delivery was 1976 ± 1654 mL. Autologous blood was transfused in 64 cases. Allogeneic blood transfusion was required in five cases of massive blood loss exceeding<abstract abstract-type="main"> <title>Abstract</title> <sec id="jog12348-sec-0001" sec-type="section"> <title>Aim</title> <p>Preoperative autologous blood donation (PAD) has the advantages over allogeneic blood transfusion of theoretically no risk of viral infection and alloimmunization. However, there are some concerns regarding PAD in pregnant women, as they sometimes become anemic and adverse effects such as low blood pressure could be harmful to fetuses. In our hospital, the PAD program was implemented in 2006 and has been used in pregnant women at high risk of massive hemorrhage. In this study, the safety of PAD in pregnant women and its efficacy for avoiding allogeneic blood transfusion were investigated.</p> </sec> <sec id="jog12348-sec-0002" sec-type="section"> <title>Methods</title> <p>The hospital records of pregnant women who delivered at our hospital from January 2009 to June 2012 were reviewed and those who were enrolled in the PAD program for predicted massive hemorrhage were analyzed.</p> </sec> <sec id="jog12348-sec-0003" sec-type="section"> <title>Results</title> <p>Among the total of 3095 deliveries, 69 cases enrolled in the PAD program were analyzed. Blood donation was performed 189 times for the 69 cases. The median donated blood volume was 1200 mL (range, 400–2000). The mean blood loss during delivery was 1976 ± 1654 mL. Autologous blood was transfused in 64 cases. Allogeneic blood transfusion was required in five cases of massive blood loss exceeding 5000 mL. In the other 64 cases, no additional allogeneic blood transfusion was required. No adverse events were observed in either the pregnant women or fetuses.</p> </sec> <sec id="jog12348-sec-0004" sec-type="section"> <title>Conclusion</title> <p>For pregnant women at a high risk of massive hemorrhage, our PAD program was safe and effective for avoiding allogeneic blood transfusion.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of obstetrics and gynaecology research. Volume 40:Issue 5(2014:May)
- Journal:
- Journal of obstetrics and gynaecology research
- Issue:
- Volume 40:Issue 5(2014:May)
- Issue Display:
- Volume 40, Issue 5 (2014)
- Year:
- 2014
- Volume:
- 40
- Issue:
- 5
- Issue Sort Value:
- 2014-0040-0005-0000
- Page Start:
- 1308
- Page End:
- 1316
- Publication Date:
- 2014-04-21
- Subjects:
- Gynecology -- Periodicals
Obstetrics -- Periodicals
618.1005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1447-0756 ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=jog ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jog.12348 ↗
- Languages:
- English
- ISSNs:
- 1341-8076
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5026.055000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4275.xml