Engineering copolymeric artificial cornea with salt porogen. Issue 6 (29th June 2013)
- Record Type:
- Journal Article
- Title:
- Engineering copolymeric artificial cornea with salt porogen. Issue 6 (29th June 2013)
- Main Title:
- Engineering copolymeric artificial cornea with salt porogen
- Authors:
- Zellander, Amelia
Wardlow, Melissa
Djalilian, Ali
Zhao, Chenlin
Abiade, Jeremiah
Cho, Michael - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <p>Artificial corneas or keratoprostheses (KPros) are designed to replace diseased or damaged cornea. Although many synthetic KPros have been developed, current products are often inappropriate or inadequate for long term use due to ineffective host integration. This study presents an alternative approach of engineering a KPro that comprises a combination of poly (2‐hydroxyethyl methacrylate) (PHEMA), poly (methyl methacrylate) (PMMA), and sodium chloride (NaCl) as porogen. Based on the core‐skirt model for KPro, the porous outer portion of artificial cornea (skirt) was engineered by combining NaCl with HEMA and MMA monomers to promote tissue ingrowth from the host. The central optic (core) was designed to provide &gt;85% light transmission in the visible wavelength range and securely attached to the skirt. Mechanical tensile data indicated that our KPro (referred to as salt porogen KPro) is mechanically stable to maintain its structure in the ocular environment and during implantation. Using human corneal fibroblasts (HCFs), we demonstrate that the cells grew into the pores of the skirt and proliferated, suggesting biointegration is adequately achieved. This novel PHEMA‐PMMA copolymeric salt porogen KPro may offer a cornea replacement option that leads to minimal risk of corneal melting by permitting sufficient tissue ingrowth and mass transport. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A:<abstract abstract-type="main"> <title>Abstract</title> <p>Artificial corneas or keratoprostheses (KPros) are designed to replace diseased or damaged cornea. Although many synthetic KPros have been developed, current products are often inappropriate or inadequate for long term use due to ineffective host integration. This study presents an alternative approach of engineering a KPro that comprises a combination of poly (2‐hydroxyethyl methacrylate) (PHEMA), poly (methyl methacrylate) (PMMA), and sodium chloride (NaCl) as porogen. Based on the core‐skirt model for KPro, the porous outer portion of artificial cornea (skirt) was engineered by combining NaCl with HEMA and MMA monomers to promote tissue ingrowth from the host. The central optic (core) was designed to provide &gt;85% light transmission in the visible wavelength range and securely attached to the skirt. Mechanical tensile data indicated that our KPro (referred to as salt porogen KPro) is mechanically stable to maintain its structure in the ocular environment and during implantation. Using human corneal fibroblasts (HCFs), we demonstrate that the cells grew into the pores of the skirt and proliferated, suggesting biointegration is adequately achieved. This novel PHEMA‐PMMA copolymeric salt porogen KPro may offer a cornea replacement option that leads to minimal risk of corneal melting by permitting sufficient tissue ingrowth and mass transport. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A: 1799–1808, 2014.</p> </abstract> … (more)
- Is Part Of:
- Journal of biomedical materials research. Volume 102:Issue 6(2014:Aug.)
- Journal:
- Journal of biomedical materials research
- Issue:
- Volume 102:Issue 6(2014:Aug.)
- Issue Display:
- Volume 102, Issue 6 (2014)
- Year:
- 2014
- Volume:
- 102
- Issue:
- 6
- Issue Sort Value:
- 2014-0102-0006-0000
- Page Start:
- 1799
- Page End:
- 1808
- Publication Date:
- 2013-06-29
- Subjects:
- Biomedical materials -- Periodicals
610.28 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1552-4965 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jbm.a.34852 ↗
- Languages:
- English
- ISSNs:
- 1549-3296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.720000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4058.xml