A novel standardized bone model for thermal evaluation of bone osteotomies with various irrigation methods. Issue 5 (24th January 2013)
- Record Type:
- Journal Article
- Title:
- A novel standardized bone model for thermal evaluation of bone osteotomies with various irrigation methods. Issue 5 (24th January 2013)
- Main Title:
- A novel standardized bone model for thermal evaluation of bone osteotomies with various irrigation methods
- Authors:
- Strbac, Georg D.
Giannis, Katharina
Unger, Ewald
Mittlböck, Martina
Watzek, Georg
Zechner, Werner - Abstract:
- <abstract abstract-type="main" id="clr12090-abs-0001"> <title>Abstract</title> <sec id="clr12090-sec-0001" sec-type="section"> <title>Objectives</title> <p>Based on a novel standardized bovine specimen, the aim of this study was to investigate thermal effects of different irrigation methods during intermittent and graduated drilling.</p> </sec> <sec id="clr12090-sec-0002" sec-type="section"> <title>Material and methods</title> <p>Temperature changes during implant osteotomies (<italic>n</italic> = 320) of 10 and 16 mm drilling depths with various irrigation methods were investigated on manufactured uniform bone samples providing homogenous cortical and cancellous areas and analogous thermal conductivity comparable to human bone. Automated sequences were performed with surgical twist drills of 2 mm ∅ and conical drills of 3.5, 4.3 and 5 mm ∅. Real‐time recording of temperature increase was done using two custom‐built multichannel thermoprobes with 14 temperature sensors at a predefined distance of 1 and 2 mm to the final osteotomy. The effects of drilling depth, drilling diameter and irrigation methods on temperature changes were investigated by a linear mixed model.</p> </sec> <sec id="clr12090-sec-0003" sec-type="section"> <title>Results</title> <p>Using this uniform bone specimen, the greatest temperature rise was observed without any coolant supply with 29.87°C, followed by external with 28.47°C and then internal with 25.86°C and combined irrigation with 25.68°C.<abstract abstract-type="main" id="clr12090-abs-0001"> <title>Abstract</title> <sec id="clr12090-sec-0001" sec-type="section"> <title>Objectives</title> <p>Based on a novel standardized bovine specimen, the aim of this study was to investigate thermal effects of different irrigation methods during intermittent and graduated drilling.</p> </sec> <sec id="clr12090-sec-0002" sec-type="section"> <title>Material and methods</title> <p>Temperature changes during implant osteotomies (<italic>n</italic> = 320) of 10 and 16 mm drilling depths with various irrigation methods were investigated on manufactured uniform bone samples providing homogenous cortical and cancellous areas and analogous thermal conductivity comparable to human bone. Automated sequences were performed with surgical twist drills of 2 mm ∅ and conical drills of 3.5, 4.3 and 5 mm ∅. Real‐time recording of temperature increase was done using two custom‐built multichannel thermoprobes with 14 temperature sensors at a predefined distance of 1 and 2 mm to the final osteotomy. The effects of drilling depth, drilling diameter and irrigation methods on temperature changes were investigated by a linear mixed model.</p> </sec> <sec id="clr12090-sec-0003" sec-type="section"> <title>Results</title> <p>Using this uniform bone specimen, the greatest temperature rise was observed without any coolant supply with 29.87°C, followed by external with 28.47°C and then internal with 25.86°C and combined irrigation with 25.68°C. Significant differences (<italic>P </italic>≤ 0.0156) between drill depths of 10 vs. 16 mm could be observed with all irrigation methods evaluated. With each of the irrigation methods, significantly higher temperature changes (<italic>P </italic>&lt;<italic> </italic>0.0001) during osteotomies could be observed between twist drills of 2 mm ∅ and conical drills of 3.5, 4.3 and 5 mm ∅. During 10 and 16 mm drilling osteotomies, external irrigation showed significantly higher temperatures (<italic>P </italic>&lt;<italic> </italic>0.05) for all conical drills compared with internal or combined irrigation, respectively. Significantly lower temperatures (<italic>P </italic>&lt;<italic> </italic>0.05) could be detected with internal or combined irrigation for the use of conical drills with various diameters and drilling depths.</p> </sec> <sec id="clr12090-sec-0004" sec-type="section"> <title>Conclusions</title> <p>This fully standardized bone model provides optimized comparability for the evaluation of bone osteotomies and resulting temperature changes. As regards the efficiency of the various irrigation methods, it could be demonstrated that internal and combined irrigation appears to be more beneficial than external irrigation.</p> </sec> </abstract> … (more)
- Is Part Of:
- Clinical oral implants research. Volume 25:Issue 5(2014:May)
- Journal:
- Clinical oral implants research
- Issue:
- Volume 25:Issue 5(2014:May)
- Issue Display:
- Volume 25, Issue 5 (2014)
- Year:
- 2014
- Volume:
- 25
- Issue:
- 5
- Issue Sort Value:
- 2014-0025-0005-0000
- Page Start:
- 622
- Page End:
- 631
- Publication Date:
- 2013-01-24
- Subjects:
- Dental implants -- Research -- Periodicals
617.69 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/clr.12090 ↗
- Languages:
- English
- ISSNs:
- 0905-7161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.318000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3160.xml