Acute Safety and Efficacy of a Novel Multipolar Irrigated Radiofrequency Ablation Catheter for Pulmonary Vein Isolation. (4th December 2013)
- Record Type:
- Journal Article
- Title:
- Acute Safety and Efficacy of a Novel Multipolar Irrigated Radiofrequency Ablation Catheter for Pulmonary Vein Isolation. (4th December 2013)
- Main Title:
- Acute Safety and Efficacy of a Novel Multipolar Irrigated Radiofrequency Ablation Catheter for Pulmonary Vein Isolation
- Authors:
- DENEKE, THOMAS
SCHADE, ANJA
MÜLLER, PATRICK
SCHMITT, RAINER
CHRISTOPOULOS, GEORGIOS
KRUG, JOACHIM
SZÖLLÖSI, GEZA
MÜGGE, ANDREAS
KERBER, SEBASTIAN
NENTWICH, KARIN - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jce12316-sec-0010" sec-type="section"> <title>Introduction</title> <p>"Single shot" ablation devices to treat symptomatic atrial fibrillation have been engineered over the last years. Safety and efficacy also includes subclinical complications only detected with esophageal endoscopy or cerebral MRI in asymptomatic patients.</p> <p>We studied the acute efficacy and safety profile of a novel multipolar irrigated RF ablation catheter (nMARQ™<bold>)</bold>.</p> </sec> <sec id="jce12316-sec-0020" sec-type="section"> <title>Methods and Results</title> <p>Forty‐three patients underwent pulmonary vein isolation (PVI) using the novel ablation device. Patient baseline and procedural characteristics were documented. Efficacy of PVI was identified using only the nMARQ™ catheter. All patients underwent postablation endoscopic evaluation of the esophagus to document thermal damage and cerebral MRI (diffusion weight imaging, attenuated diffusion coefficient‐map) to document incidence and number of silent cerebral lesions (SCL).</p> <p>Effective PVI was achieved in 98% of targeted PVs in a mean procedure time of 133 minutes. A mean of 4.8, 60‐second RF applications, per PV was needed for effective PVI. No clinical procedure‐associated complications were noted. Esophageal temperature increase &gt;40.5 °C was noted in 22 (51%) patients and 14 of these had thermal esophageal lesions on endoscopic<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jce12316-sec-0010" sec-type="section"> <title>Introduction</title> <p>"Single shot" ablation devices to treat symptomatic atrial fibrillation have been engineered over the last years. Safety and efficacy also includes subclinical complications only detected with esophageal endoscopy or cerebral MRI in asymptomatic patients.</p> <p>We studied the acute efficacy and safety profile of a novel multipolar irrigated RF ablation catheter (nMARQ™<bold>)</bold>.</p> </sec> <sec id="jce12316-sec-0020" sec-type="section"> <title>Methods and Results</title> <p>Forty‐three patients underwent pulmonary vein isolation (PVI) using the novel ablation device. Patient baseline and procedural characteristics were documented. Efficacy of PVI was identified using only the nMARQ™ catheter. All patients underwent postablation endoscopic evaluation of the esophagus to document thermal damage and cerebral MRI (diffusion weight imaging, attenuated diffusion coefficient‐map) to document incidence and number of silent cerebral lesions (SCL).</p> <p>Effective PVI was achieved in 98% of targeted PVs in a mean procedure time of 133 minutes. A mean of 4.8, 60‐second RF applications, per PV was needed for effective PVI. No clinical procedure‐associated complications were noted. Esophageal temperature increase &gt;40.5 °C was noted in 22 (51%) patients and 14 of these had thermal esophageal lesions on endoscopic evaluation. A total of 26 SCLs were noted in 14 patients (33%; 1.9/patient; mean diameter of 2.3 mm, 88% of lesions were ≤3 mm).</p> </sec> <sec id="jce12316-sec-0030" sec-type="section"> <title>Conclusions</title> <p>PVI using the novel irrigated RF multipolar ablation device (nMARQ™) appears to be acutely effective. No clinical complications were identified. A high incidence of SCL (33%) and thermal esophageal lesions (33%) bears caution and further studies on long‐term efficacy and safety are needed.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 25:Number 4(2014:Apr.)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 25:Number 4(2014:Apr.)
- Issue Display:
- Volume 25, Issue 4 (2014)
- Year:
- 2014
- Volume:
- 25
- Issue:
- 4
- Issue Sort Value:
- 2014-0025-0004-0000
- Page Start:
- 339
- Page End:
- 345
- Publication Date:
- 2013-12-04
- Subjects:
- Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.12316 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3726.xml