Vacuum immobilisation reduces tumour excursion and minimises intrafraction error in a cohort study of stereotactic ablative body radiotherapy for pulmonary metastases. Issue 2 (16th September 2013)
- Record Type:
- Journal Article
- Title:
- Vacuum immobilisation reduces tumour excursion and minimises intrafraction error in a cohort study of stereotactic ablative body radiotherapy for pulmonary metastases. Issue 2 (16th September 2013)
- Main Title:
- Vacuum immobilisation reduces tumour excursion and minimises intrafraction error in a cohort study of stereotactic ablative body radiotherapy for pulmonary metastases
- Authors:
- Siva, Shankar
Devereux, Tomas
Kron, Tomas
Gill, Suki
MacManus, Michael
Bressel, Mathias
Chesson, Brent
Callahan, Jason
Pham, Daniel
Hicks, Rodney
Foroudi, Farshad
Ball, David - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <sec id="jmiro12112-sec-0001" sec-type="section"> <title>Introduction</title> <p>The purpose of this study is to assess the impact of a vacuum immobilisation system on reproducibility of patient set‐up, interfraction stability and tumour motion amplitude.</p> </sec> <sec id="jmiro12112-sec-0002" sec-type="section"> <title>Methods</title> <p>From February 2010 to February 2012 as part of a prospective clinical trial 12 patients with solitary pulmonary metastases had consecutive four‐dimensional computed tomography (4DCT) scans performed with and without vacuum immobilisation. The displacement of the tumour centroid position was recorded in each of the 10 phases of the 4DCT reconstruction. A further six patients with seven metastases underwent single fraction stereotactic ablative body radiotherapy (SABR) during this period (a total of 19 targets) and were included in an analysis of positional reproducibility and intrafraction immobilisation. Couch shifts recorded in the medio‐lateral (X), cranio‐caudal (Y) and ventero‐dorsal (Z) planes.</p> </sec> <sec id="jmiro12112-sec-0003" sec-type="section"> <title>Results</title> <p>For the 19 treatments delivered, the median (0–90% range) shift required immediately pretreatment was 1 mm (0–3) in the X‐plane, 2 mm (0–6) in the Y‐plane and 4 mm (0–8) in the Z‐plane, respectively. The mean (+/− standard deviation) of mid‐treatment shifts were 0.3 mm (+/− 0.7), 1.1 mm (+/− 2) and<abstract abstract-type="main"> <title>Abstract</title> <sec id="jmiro12112-sec-0001" sec-type="section"> <title>Introduction</title> <p>The purpose of this study is to assess the impact of a vacuum immobilisation system on reproducibility of patient set‐up, interfraction stability and tumour motion amplitude.</p> </sec> <sec id="jmiro12112-sec-0002" sec-type="section"> <title>Methods</title> <p>From February 2010 to February 2012 as part of a prospective clinical trial 12 patients with solitary pulmonary metastases had consecutive four‐dimensional computed tomography (4DCT) scans performed with and without vacuum immobilisation. The displacement of the tumour centroid position was recorded in each of the 10 phases of the 4DCT reconstruction. A further six patients with seven metastases underwent single fraction stereotactic ablative body radiotherapy (SABR) during this period (a total of 19 targets) and were included in an analysis of positional reproducibility and intrafraction immobilisation. Couch shifts recorded in the medio‐lateral (X), cranio‐caudal (Y) and ventero‐dorsal (Z) planes.</p> </sec> <sec id="jmiro12112-sec-0003" sec-type="section"> <title>Results</title> <p>For the 19 treatments delivered, the median (0–90% range) shift required immediately pretreatment was 1 mm (0–3) in the X‐plane, 2 mm (0–6) in the Y‐plane and 4 mm (0–8) in the Z‐plane, respectively. The mean (+/− standard deviation) of mid‐treatment shifts were 0.3 mm (+/− 0.7), 1.1 mm (+/− 2) and 0.8 mm (+/− 1.5) in the X, Y and Z planes, respectively. Mid‐treatment shifts were &lt;2 mm in all directions (<italic>P</italic> = &lt; 0.001). The length of treatment time correlated to the required shifts in the Z plane (<italic>r<sup>2</sup></italic> = 0.377, <italic>P</italic> = 0.005), but not in the X or Y planes (<italic>P</italic> = 0.198 and <italic>P</italic> = 0.653, respectively). In the subset of 12 patients who had two 4DCTs, the median (range) amplitude of tumour displacements in the X, Y and Z planes when immobilised were 0.9 mm (0.3–2.9), 2.6 mm (0.2–10.6) and 1.6 mm (0.5–5.5), respectively. Immobilisation reduced the volume of tumour displacement during respiration by a median of 52.6% (<italic>P</italic> = 0.021).</p> </sec> <sec id="jmiro12112-sec-0004" sec-type="section"> <title>Conclusions</title> <p>Vacuum immobilisation reduces total tumour excursion, facilitates reproducible positioning and provides robust intrafractional immobilisation during SABR treatments for pulmonary metastases.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of medical imaging and radiation oncology. Volume 58:Issue 2(2014:Apr.)
- Journal:
- Journal of medical imaging and radiation oncology
- Issue:
- Volume 58:Issue 2(2014:Apr.)
- Issue Display:
- Volume 58, Issue 2 (2014)
- Year:
- 2014
- Volume:
- 58
- Issue:
- 2
- Issue Sort Value:
- 2014-0058-0002-0000
- Page Start:
- 244
- Page End:
- 252
- Publication Date:
- 2013-09-16
- Subjects:
- Radiology, Medical -- Periodicals
Radiology, Medical -- Australasia -- Periodicals
616.0757 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1754-9485 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/1754-9485.12112 ↗
- Languages:
- English
- ISSNs:
- 1754-9477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5017.072080
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4215.xml