Aptamer‐affinity column clean‐up coupled with ultra high performance liquid chromatography and fluorescence detection for the rapid determination of ochratoxin A in ginger powder. Issue 7 (3rd March 2014)
- Record Type:
- Journal Article
- Title:
- Aptamer‐affinity column clean‐up coupled with ultra high performance liquid chromatography and fluorescence detection for the rapid determination of ochratoxin A in ginger powder. Issue 7 (3rd March 2014)
- Main Title:
- Aptamer‐affinity column clean‐up coupled with ultra high performance liquid chromatography and fluorescence detection for the rapid determination of ochratoxin A in ginger powder
- Authors:
- Yang, Xihui
Kong, Weijun
Hu, Yichen
Yang, Meihua
Huang, Luqi
Zhao, Ming
Ouyang, Zhen - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>Aptamers are single‐stranded oligonucleotides with high affinity and specificity and are widely used in targets separation and enrichment. Here, an aptamer‐affinity column (AAC) was firstly prepared in‐house through a covalent immobilization strategy. Then, ochratoxin A (OTA) in ginger powder was absorbed and enriched using the new aptamer‐based clean‐up technology for the first time, and was further analyzed by ultra high performance liquid chromatography with fluorescence detection. After optimization, the average recoveries for blank samples spiked with OTA at 5, 15, and 45 μg/kg ranged from 85.36 to 96.83%. Furthermore, the AAC exhibited a similar accuracy as an immunoaffinity column to clean up OTA in ginger powder. Above all, it exhibited better reusability, twice that of the immunoaffinity column, had lower toxicity and cost, and took less time. Of 25 contaminated ginger powder samples, OTA contamination levels ranged from 1.51 to 4.31 μg/kg, which were lower than the European Union (EU) regulatory limits. All the positive samples were further confirmed by ultra‐fast LC with MS/MS. In conclusion, the method of clean‐up based on the AAC coupled to ultra‐HPLC with fluorescence detection was rapid, specific, and sensitive for the quantitative analysis of OTA in a complex matrix.</p> </abstract>
- Is Part Of:
- Journal of separation science. Volume 37:Issue 7(2014:Apr.)
- Journal:
- Journal of separation science
- Issue:
- Volume 37:Issue 7(2014:Apr.)
- Issue Display:
- Volume 37, Issue 7 (2014)
- Year:
- 2014
- Volume:
- 37
- Issue:
- 7
- Issue Sort Value:
- 2014-0037-0007-0000
- Page Start:
- 853
- Page End:
- 860
- Publication Date:
- 2014-03-03
- Subjects:
- Separation (Technology) -- Periodicals
Chromatographic analysis -- Periodicals
543.089 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1615-9314 ↗
http://www.interscience.wiley.com/jpages/1615-9306 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jssc.201301136 ↗
- Languages:
- English
- ISSNs:
- 1615-9306
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5063.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3091.xml