High‐frequency oscillatory ventilation versus conventional ventilation: hemodynamic effects on lung and heart. Issue 3 (27th March 2014)
- Record Type:
- Journal Article
- Title:
- High‐frequency oscillatory ventilation versus conventional ventilation: hemodynamic effects on lung and heart. Issue 3 (27th March 2014)
- Main Title:
- High‐frequency oscillatory ventilation versus conventional ventilation: hemodynamic effects on lung and heart
- Authors:
- Smailys, Andrea
Mitchell, Jamie R.
Doig, Christopher J.
Tyberg, John V.
Belenkie, Israel - Abstract:
- <abstract abstract-type="main" xml:lang="en" id="phy2259-abs-0001"> <title>Abstract</title> <p>High‐frequency oscillatory ventilation (HFOV) may improve gas exchange in patients who are inadequately ventilated by conventional mechanical ventilation (CV); however, the hemodynamic consequences of switching to HFOV remain unclear. We compared the effects of CV and HFOV on pulmonary vascular conductance and left ventricular (LV) preload and performance at different airway and filling pressures. In anesthetized dogs, we measured LV dimensions, aortic and pulmonary artery (PA) flow, and mean airway (<alternatives><inline-graphic mimetype="image" xlink:href="ark:/27927/pgg4zncz9qj" xlink:type="simple" xmlns:xlink="http://www.w3.org/1999/xlink" /><mml:math altimg="urn:x-wiley:2051817X:media:phy2259:phy2259-math-0001" overflow="scroll" xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mover accent="true"><mml:mrow><mml:mi>P</mml:mi></mml:mrow><mml:mrow><mml:mo stretchy="false">¯</mml:mo></mml:mrow></mml:mover></mml:math></alternatives><sub>AW</sub>) and pericardial pressures. Catheter‐tip pressure manometers measured aortic, LV, left atrial, and PA pressures. The pericardium and chest were closed. At LV end‐diastolic pressure (<italic>P</italic><sub>LVED</sub>) = 5 mmHg and 12 mmHg, PEEP was varied (6 cm H<sub>2</sub>O, 12 cm H<sub>2</sub>O, and 18 cm H<sub>2</sub>O) during CV. Then, at airway pressures equal to those during CV, HFOV was applied at 4 Hz, 10 Hz, and 15 Hz. Increased<abstract abstract-type="main" xml:lang="en" id="phy2259-abs-0001"> <title>Abstract</title> <p>High‐frequency oscillatory ventilation (HFOV) may improve gas exchange in patients who are inadequately ventilated by conventional mechanical ventilation (CV); however, the hemodynamic consequences of switching to HFOV remain unclear. We compared the effects of CV and HFOV on pulmonary vascular conductance and left ventricular (LV) preload and performance at different airway and filling pressures. In anesthetized dogs, we measured LV dimensions, aortic and pulmonary artery (PA) flow, and mean airway (<alternatives><inline-graphic mimetype="image" xlink:href="ark:/27927/pgg4zncz9qj" xlink:type="simple" xmlns:xlink="http://www.w3.org/1999/xlink" /><mml:math altimg="urn:x-wiley:2051817X:media:phy2259:phy2259-math-0001" overflow="scroll" xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mover accent="true"><mml:mrow><mml:mi>P</mml:mi></mml:mrow><mml:mrow><mml:mo stretchy="false">¯</mml:mo></mml:mrow></mml:mover></mml:math></alternatives><sub>AW</sub>) and pericardial pressures. Catheter‐tip pressure manometers measured aortic, LV, left atrial, and PA pressures. The pericardium and chest were closed. At LV end‐diastolic pressure (<italic>P</italic><sub>LVED</sub>) = 5 mmHg and 12 mmHg, PEEP was varied (6 cm H<sub>2</sub>O, 12 cm H<sub>2</sub>O, and 18 cm H<sub>2</sub>O) during CV. Then, at airway pressures equal to those during CV, HFOV was applied at 4 Hz, 10 Hz, and 15 Hz. Increased <alternatives><inline-graphic mimetype="image" xlink:href="ark:/27927/pgg4zncz9nf" xlink:type="simple" xmlns:xlink="http://www.w3.org/1999/xlink" /><mml:math altimg="urn:x-wiley:2051817X:media:phy2259:phy2259-math-0002" overflow="scroll" xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mover accent="true"><mml:mrow><mml:mi>P</mml:mi></mml:mrow><mml:mrow><mml:mo stretchy="false">¯</mml:mo></mml:mrow></mml:mover></mml:math></alternatives><sub>AW</sub> decreased pulmonary vascular conductance. As cardiac output increased, conductance increased. At <italic>P</italic><sub>LVED </sub>= 12 mmHg, conductance was greatest during HFOV at 4 Hz. LV preload (i.e., <italic>A</italic><sub>LV</sub>, our index of end‐diastolic volume) was similar during HFOV and CV for all conditions. At <italic>P</italic><sub>LVED </sub>= 12 mmHg, SW<sub>LV</sub> was similar during CV and HFOV, but, at <italic>P</italic><sub>LVED </sub>= 5 mmHg and <alternatives><inline-graphic mimetype="image" xlink:href="ark:/27927/pgg4zncz9p0" xlink:type="simple" xmlns:xlink="http://www.w3.org/1999/xlink" /><mml:math altimg="urn:x-wiley:2051817X:media:phy2259:phy2259-math-0003" overflow="scroll" xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mover accent="true"><mml:mrow><mml:mi>P</mml:mi></mml:mrow><mml:mrow><mml:mo stretchy="false">¯</mml:mo></mml:mrow></mml:mover></mml:math></alternatives><sub>AW</sub> 10 cm H<sub>2</sub>O, SW<sub>LV</sub> was lower during HFOV than CV. Compared to pulmonary vascular conductance at higher frequencies, at <italic>P</italic><sub>LVED </sub>= 12 mmHg, conductance was greater at HFOV of 4 Hz. Effects of CV and HFOV on LV preload and performance were similar except for decreased SW<sub>LV</sub> at <italic>P</italic><sub>LVED </sub>= 5 mmHg. These observations suggest the need for further studies to assess their potential clinical relevance.</p> </abstract> … (more)
- Is Part Of:
- Physiological reports. Volume 2:Issue 3(2014:Mar.)
- Journal:
- Physiological reports
- Issue:
- Volume 2:Issue 3(2014:Mar.)
- Issue Display:
- Volume 2, Issue 3 (2014)
- Year:
- 2014
- Volume:
- 2
- Issue:
- 3
- Issue Sort Value:
- 2014-0002-0003-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2014-03-27
- Subjects:
- Physiology -- Periodicals
571 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2051-817X ↗
http://physreports.physiology.org ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/phy2.259 ↗
- Languages:
- English
- ISSNs:
- 2051-817X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3205.xml