Reducing iodinated contrast volume by manipulating injection pressure during coronary angiography. Issue 5 (7th January 2014)
- Record Type:
- Journal Article
- Title:
- Reducing iodinated contrast volume by manipulating injection pressure during coronary angiography. Issue 5 (7th January 2014)
- Main Title:
- Reducing iodinated contrast volume by manipulating injection pressure during coronary angiography
- Authors:
- Kaye, David M.
Stub, Dion
Mak, Vivian
Doan, Tuan
Duffy, Stephen J. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd25348-sec-0001" sec-type="section"> <title>Objective</title> <p>To evaluate the impact of a device‐mediated modification of the injection pressure profile on iodinated contrast volumes during coronary angiography and percutaneous coronary intervention (PCI).</p> </sec> <sec id="ccd25348-sec-0002" sec-type="section"> <title>Background</title> <p>The development of iodinated contrast‐induced acute kidney injury (AKI) is associated with significant morbidity and mortality in patients undergoing coronary angiography and intervention, particularly in the setting of ST‐elevation myocardial infarction. Iodinated contrast volume is a recognized risk factor for iodinated contrast‐induced AKI. Mitigation of iodinated contrast loss due to coronary iodinated contrast reflux represents a potential means to reduce iodinated contrast volume.</p> </sec> <sec id="ccd25348-sec-0003" sec-type="section"> <title>Method and Results</title> <p>We assessed the effectiveness of injection pressure modulation using an iodinated contrast conservation system (CCS), in 21 patients undergoing diagnostic coronary angiography or PCI. System activation was associated with a marked reduction in iodinated contrast injection compared with standard imaging (3.5 ± 1.1 vs. 5.4 ± 1.7 mL, <italic>P</italic> &lt; 0.001). Paired images were obtained in 59 instances with significantly less iodinated contrast use with CCS<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd25348-sec-0001" sec-type="section"> <title>Objective</title> <p>To evaluate the impact of a device‐mediated modification of the injection pressure profile on iodinated contrast volumes during coronary angiography and percutaneous coronary intervention (PCI).</p> </sec> <sec id="ccd25348-sec-0002" sec-type="section"> <title>Background</title> <p>The development of iodinated contrast‐induced acute kidney injury (AKI) is associated with significant morbidity and mortality in patients undergoing coronary angiography and intervention, particularly in the setting of ST‐elevation myocardial infarction. Iodinated contrast volume is a recognized risk factor for iodinated contrast‐induced AKI. Mitigation of iodinated contrast loss due to coronary iodinated contrast reflux represents a potential means to reduce iodinated contrast volume.</p> </sec> <sec id="ccd25348-sec-0003" sec-type="section"> <title>Method and Results</title> <p>We assessed the effectiveness of injection pressure modulation using an iodinated contrast conservation system (CCS), in 21 patients undergoing diagnostic coronary angiography or PCI. System activation was associated with a marked reduction in iodinated contrast injection compared with standard imaging (3.5 ± 1.1 vs. 5.4 ± 1.7 mL, <italic>P</italic> &lt; 0.001). Paired images were obtained in 59 instances with significantly less iodinated contrast use with CCS use (3.3 ± 1.1 vs. 5.5 ± 1.6 mL, <italic>P</italic> &lt; 0.001), with comparable image quality in 98% of cases.</p> </sec> <sec id="ccd25348-sec-0004" sec-type="section"> <title>Conclusions</title> <p>Modulation of iodinated contrast injection pressure provides a novel potential means to reduce iodinated contrast volumes by attenuating inefficient losses due to ostial reflux. Future studies are required to define the ability of the CCS to reduce total iodinated contrast volume and to impact upon the risk of iodinated contrast‐induced AKI. © 2013 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 83:Issue 5(2014:Apr. 01)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 83:Issue 5(2014:Apr. 01)
- Issue Display:
- Volume 83, Issue 5 (2014)
- Year:
- 2014
- Volume:
- 83
- Issue:
- 5
- Issue Sort Value:
- 2014-0083-0005-0000
- Page Start:
- 741
- Page End:
- 745
- Publication Date:
- 2014-01-07
- Subjects:
- Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.25348 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3130.xml