Quantification of hepatic steatosis: A comparison of the accuracy among multiple magnetic resonance techniques. Issue 4 (April 2014)
- Record Type:
- Journal Article
- Title:
- Quantification of hepatic steatosis: A comparison of the accuracy among multiple magnetic resonance techniques. Issue 4 (April 2014)
- Main Title:
- Quantification of hepatic steatosis: A comparison of the accuracy among multiple magnetic resonance techniques
- Authors:
- Wu, Chih‐Horng
Ho, Ming‐Chih
Jeng, Yung‐Ming
Hsu, Chao‐Yu
Liang, Po‐Chin
Hu, Rey‐Heng
Lai, Hong‐Shiee
Shih, Tiffany Ting‐Fang - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <sec id="jgh12451-sec-0001" sec-type="section"> <title>Background and Aim</title> <p>Magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) are important diagnostic tools for the non‐invasive assessment of hepatic steatosis (HS). This study was conducted to compare different magnetic resonance (MR) techniques and correlate the MR findings with histological and intracellular lipid density findings.</p> </sec> <sec id="jgh12451-sec-0002" sec-type="section"> <title>Methods</title> <p>In this institutional review board‐approved, Health Insurance Portability and Accountability Act‐compliant prospective study, 60 patients scheduled for liver resection were included in this study. Fat fraction in the non‐tumorous liver parenchyma was estimated using double‐echo MRI, triple‐echo MRI (TE‐MRI), and MRS. HS was defined by the histologic steatosis percentage (HSP), and intrahepatocellular triglyceride density (IHTGD) of the surgical specimen used as the reference standard. Imaging quantification results were evaluated using Pearson's correlation. Lin's concordance coefficient and Bland–Altman 95% limits of agreement were used to evaluate the concordance of IHTGDs estimated by the three MR techniques. The diagnostic performance was compared using receiver operating characteristic curve analysis.</p> </sec> <sec id="jgh12451-sec-0003" sec-type="section"> <title>Results</title> <p>HS assessed by TE‐MRI and MRS had<abstract abstract-type="main"> <title>Abstract</title> <sec id="jgh12451-sec-0001" sec-type="section"> <title>Background and Aim</title> <p>Magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) are important diagnostic tools for the non‐invasive assessment of hepatic steatosis (HS). This study was conducted to compare different magnetic resonance (MR) techniques and correlate the MR findings with histological and intracellular lipid density findings.</p> </sec> <sec id="jgh12451-sec-0002" sec-type="section"> <title>Methods</title> <p>In this institutional review board‐approved, Health Insurance Portability and Accountability Act‐compliant prospective study, 60 patients scheduled for liver resection were included in this study. Fat fraction in the non‐tumorous liver parenchyma was estimated using double‐echo MRI, triple‐echo MRI (TE‐MRI), and MRS. HS was defined by the histologic steatosis percentage (HSP), and intrahepatocellular triglyceride density (IHTGD) of the surgical specimen used as the reference standard. Imaging quantification results were evaluated using Pearson's correlation. Lin's concordance coefficient and Bland–Altman 95% limits of agreement were used to evaluate the concordance of IHTGDs estimated by the three MR techniques. The diagnostic performance was compared using receiver operating characteristic curve analysis.</p> </sec> <sec id="jgh12451-sec-0003" sec-type="section"> <title>Results</title> <p>HS assessed by TE‐MRI and MRS had a stronger relationship with HS assessed by HSP and IHTGD. The TE‐MRI method had the highest concordance correlation coefficients (ρ = 0.881) and percentage (95%, 57/60) within the Bland–Altman 95% limits of agreement. Receiver operating characteristic curve analysis for diagnosing &gt; 5% HSP showed significantly larger area under the curve (0.9783) for TE‐MRI than for double‐echo MRI (0.8773, <italic>P</italic> = 0.0121).</p> </sec> <sec id="jgh12451-sec-0004" sec-type="section"> <title>Conclusions</title> <p>Among the three MR techniques, TE‐MRI and MRS may be the preferred techniques for non‐invasive assessment of HS.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of gastroenterology and hepatology. Volume 29:Issue 4(2014:Apr.)
- Journal:
- Journal of gastroenterology and hepatology
- Issue:
- Volume 29:Issue 4(2014:Apr.)
- Issue Display:
- Volume 29, Issue 4 (2014)
- Year:
- 2014
- Volume:
- 29
- Issue:
- 4
- Issue Sort Value:
- 2014-0029-0004-0000
- Page Start:
- 807
- Page End:
- 813
- Publication Date:
- 2014-04
- Subjects:
- Gastroenterology -- Periodicals
Digestive organs -- Diseases -- Periodicals
Liver -- Diseases -- Periodicals
Gastroenterology -- Periodicals
Liver Diseases -- Periodicals
616.33 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1440-1746 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.blackwell-synergy.com/loi/jgh ↗ - DOI:
- 10.1111/jgh.12451 ↗
- Languages:
- English
- ISSNs:
- 0815-9319
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4987.615000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3474.xml