Clinical and Radiological Outcomes of Two Implants with Different Prosthetic Interfaces and Neck Configurations: Randomized, Controlled, Split‐Mouth Clinical Trial. (1st June 2012)
- Record Type:
- Journal Article
- Title:
- Clinical and Radiological Outcomes of Two Implants with Different Prosthetic Interfaces and Neck Configurations: Randomized, Controlled, Split‐Mouth Clinical Trial. (1st June 2012)
- Main Title:
- Clinical and Radiological Outcomes of Two Implants with Different Prosthetic Interfaces and Neck Configurations: Randomized, Controlled, Split‐Mouth Clinical Trial
- Authors:
- Pozzi, Alessandro
Agliardi, Enrico
Tallarico, Marco
Barlattani, Alberto - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>ABSTRACT</title> <p> <bold>Background:</bold> Peri‐implant bone loss seems to occur following implant placement/loading regardless of all the efforts to eliminate it. Several factors, including surgical trauma, biologic width establishment, lack of passive fit of the superstructures, implant‐abutment microgap, and occlusal overloading, may increase peri‐implant bone loss. Over the years, new interface designs were introduced and clinical studies suggest that internal conical connection and platform shifting may be advantageous for marginal bone preservation.</p> <p> <bold>Purpose:</bold> To compare clinical and radiological outcomes of two implant designs with different prosthetic interfaces and neck configurations in a randomized, controlled, split‐mouth clinical trial.</p> <p> <bold>Materials and Methods:</bold> Thirty‐four partially edentate patients randomly received at least one internal conical connection with back‐tapered collar and platform shifting design or external‐hexagon implants with flat‐to‐flat implant‐abutment interface. Primary end point was peri‐implant bone level changes at different time points, failures of implants and/or prosthesis, any complications, implant stability quotient (ISQ) values, and periodontal parameters.</p> <p> <bold>Results:</bold> No dropout occurred. Marginal bone changes were statistically significantly different with better results for the internal conical connection. No implants<abstract abstract-type="main" xml:lang="en"> <title>ABSTRACT</title> <p> <bold>Background:</bold> Peri‐implant bone loss seems to occur following implant placement/loading regardless of all the efforts to eliminate it. Several factors, including surgical trauma, biologic width establishment, lack of passive fit of the superstructures, implant‐abutment microgap, and occlusal overloading, may increase peri‐implant bone loss. Over the years, new interface designs were introduced and clinical studies suggest that internal conical connection and platform shifting may be advantageous for marginal bone preservation.</p> <p> <bold>Purpose:</bold> To compare clinical and radiological outcomes of two implant designs with different prosthetic interfaces and neck configurations in a randomized, controlled, split‐mouth clinical trial.</p> <p> <bold>Materials and Methods:</bold> Thirty‐four partially edentate patients randomly received at least one internal conical connection with back‐tapered collar and platform shifting design or external‐hexagon implants with flat‐to‐flat implant‐abutment interface. Primary end point was peri‐implant bone level changes at different time points, failures of implants and/or prosthesis, any complications, implant stability quotient (ISQ) values, and periodontal parameters.</p> <p> <bold>Results:</bold> No dropout occurred. Marginal bone changes were statistically significantly different with better results for the internal conical connection. No implants and prosthesis failures have been observed, yielding a cumulative survival rate of 100%. A high ISQ value was found for both implants, and no statistically significant difference was found for ISQ mean values between interventions at each time point (<italic>p</italic> &gt; .05). All implants showed no bleeding on probing and a very slight amount of plaque at the 1‐year‐in‐function visit.</p> <p> <bold>Conclusions:</bold> Both implant designs investigated performed similarly in terms of failure rates, providing successful results up to 1 year after loading. The back‐tapered neck configuration with conical connection and built‐in platform shifting showed statistically lower marginal bone loss than straight neck configuration with flat‐to‐flat implant‐abutment interface and external‐hexagonal connection.</p> </abstract> … (more)
- Is Part Of:
- Clinical implant dentistry and related research. Volume 16:Number 1(2014:Feb.)
- Journal:
- Clinical implant dentistry and related research
- Issue:
- Volume 16:Number 1(2014:Feb.)
- Issue Display:
- Volume 16, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 16
- Issue:
- 1
- Issue Sort Value:
- 2014-0016-0001-0000
- Page Start:
- 96
- Page End:
- 106
- Publication Date:
- 2012-06-01
- Subjects:
- Dental implants -- Periodicals
Dental Implantation -- Periodicals
Dental Implants -- Periodicals
617.693 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/j.1708-8208.2012.00465.x ↗
- Languages:
- English
- ISSNs:
- 1523-0899
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.293825
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3299.xml