Endothelial function and carotid intima‐media thickness in giant‐cell arteritis. (2nd January 2014)
- Record Type:
- Journal Article
- Title:
- Endothelial function and carotid intima‐media thickness in giant‐cell arteritis. (2nd January 2014)
- Main Title:
- Endothelial function and carotid intima‐media thickness in giant‐cell arteritis
- Authors:
- Hafner, Franz
Haas, Elke
Belaj, Klara
Froehlich, Harald
Gary, Thomas
Eller, Philipp
Brodmann, Marianne - Abstract:
- <abstract abstract-type="main" id="eci12227-abs-0001"> <title>Abstract</title> <sec id="eci12227-sec-0001" sec-type="section"> <title>Background</title> <p>Vascular endothelial dysfunction and intima‐media thickness are characteristic aspects of several vasculitides. We investigated retrospectively the impact of steroid treatment on endothelial dysfunction and intima‐media thickness in giant‐cell arteritis.</p> </sec> <sec id="eci12227-sec-0002" sec-type="section"> <title>Methods</title> <p>Forty‐one patients with giant‐cell arteritis (28 female and 13 male) underwent flow‐mediated dilatation, a marker of endothelial function, and carotid intima‐media thickness within 24 h after diagnosis and 6 months thereafter. Both parameters were investigated in 41 patients of an age‐ and gender‐matched control group.</p> </sec> <sec id="eci12227-sec-0003" sec-type="section"> <title>Results</title> <p>Brachial flow‐mediated dilatation response at baseline was 3·4% (0·2, 8·0) and 1·7% (0·2, 4·8) in giant‐cell arteritis patients and control group, respectively. After 6 months treatment, flow‐mediated dilatation response was 2·8% (0·4, 4·8) in patients with giant‐cell arteritis (<italic>P</italic> = 0·066) and 1·4% (0·1, 5·5) in the control group (<italic>P</italic> = 0·741). In contrast, mean carotid intima‐media thickness of giant‐cell arteritis patients improved significantly between baseline [1·0 mm (0·79, 1·2)] and 6‐month follow‐up [0·82 mm (0·7, 1·04), <italic>P</italic> &lt; 0·001].<abstract abstract-type="main" id="eci12227-abs-0001"> <title>Abstract</title> <sec id="eci12227-sec-0001" sec-type="section"> <title>Background</title> <p>Vascular endothelial dysfunction and intima‐media thickness are characteristic aspects of several vasculitides. We investigated retrospectively the impact of steroid treatment on endothelial dysfunction and intima‐media thickness in giant‐cell arteritis.</p> </sec> <sec id="eci12227-sec-0002" sec-type="section"> <title>Methods</title> <p>Forty‐one patients with giant‐cell arteritis (28 female and 13 male) underwent flow‐mediated dilatation, a marker of endothelial function, and carotid intima‐media thickness within 24 h after diagnosis and 6 months thereafter. Both parameters were investigated in 41 patients of an age‐ and gender‐matched control group.</p> </sec> <sec id="eci12227-sec-0003" sec-type="section"> <title>Results</title> <p>Brachial flow‐mediated dilatation response at baseline was 3·4% (0·2, 8·0) and 1·7% (0·2, 4·8) in giant‐cell arteritis patients and control group, respectively. After 6 months treatment, flow‐mediated dilatation response was 2·8% (0·4, 4·8) in patients with giant‐cell arteritis (<italic>P</italic> = 0·066) and 1·4% (0·1, 5·5) in the control group (<italic>P</italic> = 0·741). In contrast, mean carotid intima‐media thickness of giant‐cell arteritis patients improved significantly between baseline [1·0 mm (0·79, 1·2)] and 6‐month follow‐up [0·82 mm (0·7, 1·04), <italic>P</italic> &lt; 0·001]. Subjects with additional symptoms of polymyalgia rheumatica had a notable enlargement of carotid intima‐media thickness [1·23 mm (1·14, 2·09)] compared to giant‐cell arteritis patients without polymyalgia rheumatica at baseline [0·91 mm (0·76, 1·04), <italic>P</italic> = 0·001] and 6‐month follow‐up [1·16 mm (0·80, 1·26) vs. 0·77 mm (0·68, 0·88), <italic>P</italic> = 0·009].</p> </sec> <sec id="eci12227-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Steroid therapy has no influence on endothelial function but does significantly improve carotid intima‐media thickness in giant‐cell arteritis. This divergence of endothelial function and intima‐media thickness reflects the specifity of giant‐cell arteritis for cerebrovascular arteries thereby sparing the brachial arteries.</p> </sec> </abstract> … (more)
- Is Part Of:
- European journal of clinical investigation. Volume 44:Number 3(2014:Mar.)
- Journal:
- European journal of clinical investigation
- Issue:
- Volume 44:Number 3(2014:Mar.)
- Issue Display:
- Volume 44, Issue 3 (2014)
- Year:
- 2014
- Volume:
- 44
- Issue:
- 3
- Issue Sort Value:
- 2014-0044-0003-0000
- Page Start:
- 249
- Page End:
- 256
- Publication Date:
- 2014-01-02
- Subjects:
- Pathology -- Periodicals
Medical research -- Periodicals
616.075 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2362 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/eci.12227 ↗
- Languages:
- English
- ISSNs:
- 0014-2972
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.727100
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3910.xml